View all
Modicon ABE7

ABE7H08R11
ABE7H08R11 is replaced by:
Product
Qty
-
Characteristics
Main range of product Modicon ABE7product or component type Passive discrete I/O sub-basesub-base type I/O sub-base[Us] rated supply voltage 19...30 V conforming to IEC 61131-2number of channels 8number of terminal per channel 1connections - terminals Screw type terminals, 1 x 0.09...1 x 1.5 mm² (AWG 28...AWG 16) flexible with cable endScrew type terminals, 1 x 0.14...1 x 2.5 mm² (AWG 26...AWG 12) solidScrew type terminals, 1 x 0.14...1 x 2.5 mm² (AWG 26...AWG 14) flexible without cable endScrew type terminals, 2 x 0.09...2 x 0.75 mm² (AWG 28...AWG 20) flexible with cable endScrew type terminals, 2 x 0.2...2 x 2.5 mm² (AWG 24...AWG 14) solidComplementary supply voltage type DCnumber of horizontal rows 1status LED 1 LED per channel (green)channel status: 1 LED (green)power ON:polarity distribution Noshort-circuit protection 6.3 A internal fuse, 5 x 20 mm, fast blow (PLC end)connector type HE-10pin number 20 pinsfixing mode By clips (35 mm symmetrical DIN rail)By screws (solid plate with fixing kit)maximum supply current 4.1 Acurrent per channel 0.5 Amaximum current per output common 4.1 Avoltage drop on power supply fuse 0.2 V[Ui] rated insulation voltage 2000 Vinstallation category II conforming to IEC 60664-1tightening torque 0.6 N.m with flat Ø 3.5 mm screwdriverwidth 84 mmnet weight 0.187 kgEnvironment product certifications GLLROS (Lloyds register of shipping)DNVBVCSAULIP degree of protection IP2x conforming to IEC 60529resistance to incandescent wire 750 °C conforming to IEC 60695-2-11shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27vibration resistance 2 gn (f= 10…150 Hz) conforming to IEC 60068-2-6resistance to electrostatic discharge 4 kV (contact) level 3 conforming to IEC 61000-4-28 kV (air) level 3 conforming to IEC 61000-4-2resistance to radiated fields 10 V/m (26000000…1000000000 Hz) conforming to IEC 61000-4-3 level 3resistance to fast transients 2 kV level 3 conforming to IEC 61000-4-4ambient air temperature for operation -5…60 °C conforming to IEC 61131-2ambient air temperature for storage -40…80 °C conforming to IEC 61131-2pollution degree 2 conforming to IEC 60664-1Offer Sustainability Sustainable offer status Green Premium productREACh Regulation REACh free of SVHC YesEU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages75
- English12
- Chinese7
- French60
- German7
- Italian7
- Spanish7
CatalogueFormatSizeAdd to My DocumentsTelefast Pre-wired system : Modicon ABE7 IP20 connection sub-bases, Modicon ABE9 IP67 passive splitter boxes (Version 3.2)Size pdfSize 10.8 MBDate 10/4/19Système de précâblage Telefast, Embases de raccordement IP20 Modicon ABE7, Répartiteurs passifs IP67 Modicon ABE9 (Version 3.2)Size pdfSize 9 MBDate 10/3/19User guideFormatSizeAdd to My DocumentsModicon X80 - Discrete Input / Output Modules, User Manual (Version 15)DescriptionThis manual describes the hardware and software installation of Modicon X80 discrete modules.Size pdfSize 8.3 MBDate 12/1/18DescriptionThis manual describes the hardware and software installation of Modicon X80 discrete modules.Modicon X80 - 离散量输入/输出模块 , 用户手册 (Version 14)Description本手册介绍了 Modicon X80 离散量模块的软硬件实施。Size pdfSize 7.9 MBDate 12/1/18Description本手册介绍了 Modicon X80 离散量模块的软硬件实施。使用 EcoStruxure™ Control Expert 的 Premium 和 Atrium - 离散量 I/O 模块 , 用户手册 (Version 09)Description本手册介绍了针对 Premium 和 Atrium PLC 的离散量模块的硬件和软件实施。Size pdfSize 5.1 MBDate 12/1/18Description本手册介绍了针对 Premium 和 Atrium PLC 的离散量模块的硬件和软件实施。Premium et Atrium sous EcoStruxure™ Control Expert - Modules d'E/S TOR, Manuel utilisateur (Version 10)DescriptionCe manuel présente la mise en oeuvre matérielle et logicielle des modules TOR pour automates Premium et Atrium.Size pdfSize 5.3 MBDate 12/1/18DescriptionCe manuel présente la mise en oeuvre matérielle et logicielle des modules TOR pour automates Premium et Atrium.Modicon X80 - Modules d'entrée / sortie TOR, Manuel utilisateur (Version 14)DescriptionCe manuel décrit l'installation matérielle et logicielle des modules TOR Modicon X80.Size pdfSize 8.1 MBDate 12/1/18DescriptionCe manuel décrit l'installation matérielle et logicielle des modules TOR Modicon X80.Premium und Atrium unter EcoStruxure™ Control Expert - Digitale E/A-Module, Benutzerhandbuch (Version 12)DescriptionIn diesem Handbuch wird die Installation der digitalen Module (Hardware und Software) für Premium- und Atrium-Steuerungen beschrieben.Size pdfSize 5.5 MBDate 12/1/18DescriptionIn diesem Handbuch wird die Installation der digitalen Module (Hardware und Software) für Premium- und Atrium-Steuerungen beschrieben.Modicon X80 - Digitale Eingangs-/ Ausgangsmodule, Benutzerhandbuch (Version 14)DescriptionIn diesem Handbuch wird die Hardware- und Softwareinstallation der Modicon X80-Digitalmodule beschrieben.Size pdfSize 8.1 MBDate 12/1/18DescriptionIn diesem Handbuch wird die Hardware- und Softwareinstallation der Modicon X80-Digitalmodule beschrieben.Premium e Atrium con EcoStruxure™ Control Expert - Moduli di I/O digitali, Manuale dell’utente (Version 08)DescriptionIn questo manuale viene descritta l'implementazione hardware e software di moduli digitali per PLC Premium e Atrium.Size pdfSize 5.5 MBDate 12/1/18DescriptionIn questo manuale viene descritta l'implementazione hardware e software di moduli digitali per PLC Premium e Atrium.Modicon X80 - Moduli di I/O digitali, Manuale dell’utente (Version 14)DescriptionQuesto manuale descrive l'installazione hardware e software dei moduli digitali Modicon X80.Size pdfSize 8 MBDate 12/1/18DescriptionQuesto manuale descrive l'installazione hardware e software dei moduli digitali Modicon X80.Premium y Atrium con EcoStruxure™ Control Expert - Módulos de E/S binarios, Manual de usuario (Version 12)DescriptionEn este manual se describe la instalación del hardware y el software de los módulos binarios para los PLC Premium y Atrium.Size pdfSize 5.4 MBDate 12/1/18DescriptionEn este manual se describe la instalación del hardware y el software de los módulos binarios para los PLC Premium y Atrium.Modicon X80 - Módulos de entradas / salidas binarias, Manual de usuario (Version 14)DescriptionEn este manual se describe la instalación de hardware y software de los módulos binarios Modicon X80.Size pdfSize 8.2 MBDate 12/1/18DescriptionEn este manual se describe la instalación de hardware y software de los módulos binarios Modicon X80.CADFormatSizeAdd to My DocumentsSize zipSize 253.7 KBDate 1/13/05Size zipSize 318.3 KBDate 1/13/05Instruction sheetFormatSizeAdd to My DocumentsCatalogue pageFormatSizeAdd to My DocumentsSize pdfSize 641.8 KBDate 2/27/18Size pdfSize 368.9 KBDate 3/24/16Size pdfSize 234.7 KBDate 2/1/16Modicon Quantum - Sytème Hot Standby (Unity Pro) : presentation / description / reference (Version 2.1)Size pdfSize 479.7 KBDate 2/1/16Modicon Quantum - Modules de comptage et modules spécifiques : présentation / description / références (Version 2.1)Size pdfSize 252.7 KBDate 2/1/16Plates-formes d'automatisme Modicon - Architectures Ethernet PlantStruxure : serveurs et passerelles Web FactoryCast (Version 8.1)Size pdfSize 121.6 KBDate 2/1/16Plates-formes d'automatisme Modicon - Architectures Ethernet PlantStruxure : services Web actif FactoryCast HM (Version 6.1)Size pdfSize 522.4 KBDate 2/1/16Plates-formes d'automatisme Modicon - Architectures Ethernet PlantStruxure : services Web de base (Version 8.0)Size pdfSize 255.1 KBDate 2/1/16Plates-formes d'automatisme Modicon Quantum- Réseaux EtherNet/IP et Modbus/TCP : characterists (Version 1.0)Size pdfSize 98.9 KBDate 2/1/16Plates-formes d'automatisme Modicon - Réseaux EtherNet/IP et Modbus/TCP : performances (Version 6.0)Size pdfSize 174.6 KBDate 2/1/16Size pdfSize 45.1 KBDate 2/1/16Size pdfSize 1,009.1 KBDate 2/1/16Size pdfSize 329.6 KBDate 2/1/16Size pdfSize 205.5 KBDate 2/1/16Size pdfSize 158.9 KBDate 2/1/16Size pdfSize 198.1 KBDate 2/1/16Modicon Quantum - Modules d'entrées/sorties TOR : présentation / description / références (Version 2.1)Size pdfSize 244.2 KBDate 2/1/16Modicon Quantum - Modules d'entrées/sorties analogiques : présentation / description / références (Version 2.1)Size pdfSize 120.2 KBDate 2/1/16Modicon Quantum - AS-Interface, coupleur maitre : présentation /description /références (Version 2.1)Size pdfSize 66.7 KBDate 2/1/16Size pdfSize 431.1 KBDate 2/1/16Size pdfSize 210.4 KBDate 2/1/16Size pdfSize 67.6 KBDate 2/1/16Size pdfSize 114.8 KBDate 2/1/16Size pdfSize 228.2 KBDate 2/1/16Size pdfSize 210.3 KBDate 2/1/16Size pdfSize 342.2 KBDate 2/1/16Modicon Quantum - Pocesseurs avec port Ethernet et coupleurs réseau Ethernet : présentation /description /références (Version 3.0)Size pdfSize 88.6 KBDate 2/1/16Modicon Quantum - Module réseau EtherNet/IP et Modbus/TCP : présentation /description /références (Version 2.1)Size pdfSize 179.5 KBDate 2/1/16Size pdfSize 496.6 KBDate 2/1/16Size pdfSize 587.3 KBDate 2/1/16Modicon Quantum - Architectures d'E/S (bus S908) : présentation / description / référence (Version 5.0)Size pdfSize 489.8 KBDate 2/1/16Size pdfSize 133.9 KBDate 2/1/16Size pdfSize 303.7 KBDate 2/1/16Size pdfSize 158 KBDate 2/1/16Size pdfSize 290.3 KBDate 2/1/16Size pdfSize 76.4 KBDate 2/1/16Size pdfSize 521.5 KBDate 2/1/16Plates-formes d'automatisme Modicon - Architectures Ethernet PlantStruxure : services Web SOAP/XML (Version 7.1)Size pdfSize 81.1 KBDate 2/1/16Modicon Quantum - Architectures Ethernet I/O : présentation, description, architectures, références (Version 3.1)Size pdfSize 2.4 MBDate 2/1/16Size pdfSize 225.6 KBDate 2/1/16Size pdfSize 246.3 KBDate 2/1/16Laison série - Module de liaison série asynchrone : présentation / description / références (Version 2.1)Size pdfSize 63.1 KBDate 2/1/16Declaration of conformityFormatSizeAdd to My DocumentsSize pdfSize 1.7 MBDate 1/25/17End of Life InformationFormatSizeAdd to My DocumentsSize pdfSize 442.1 KBDate 8/1/16Size pdfSize 267.8 KBDate 11/1/11EU RoHS DeclarationFormatSizeAdd to My Documentspassive connection sub-base ABE7 - 8 inputs or outputs - LedDescriptionpassive connection sub-base ABE7 - 8 inputs or outputs - LedSize pdfSize 195.3 KBDate 12/9/19Descriptionpassive connection sub-base ABE7 - 8 inputs or outputs - LedMarine certificateFormatSizeAdd to My DocumentsREACh DeclarationFormatSizeAdd to My Documentspassive connection sub-base ABE7 - 8 inputs or outputs - LedDescriptionpassive connection sub-base ABE7 - 8 inputs or outputs - LedSize pdfSize 195.3 KBDate 12/9/19Descriptionpassive connection sub-base ABE7 - 8 inputs or outputs - LedChina RoHS declarationFormatSizeAdd to My Documentspassive connection sub-base ABE7 - 8 inputs or outputs - LedDescriptionpassive connection sub-base ABE7 - 8 inputs or outputs - LedSize pdfSize 195.3 KBDate 12/9/19Descriptionpassive connection sub-base ABE7 - 8 inputs or outputs - Led -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
Dimensions(1)ABE7BV10 / ABE7BV10E -
Mounting and Clearance
Mounting -
Connections and Schema
HE10 8 ChannelsWiring Diagrams(1)Inductive load -
Performance Curves
Curves for Determining Cable Type and Length According to the Current8-channel Sub-baseLCable lengthITTotal current per sub base (A)IAAverage current per channel (mA)(1)TSXCDP••2 and ABFH20H••0 cables with c.s.a. 0.08 mm2 (AWG 28).(2)TSXCDP••3 cables with c.s.a. 0.34 mm2 (AWG 22).(3)Cables with c.s.a. 0.13 mm2 (AWG 26).The curves are given for a voltage drop of 1 V in the cable. For n volts tolerance, multiply the length determined from the graph by n.