Characteristics
Main range of product Modicon ABE7product or component type Sub-base for plug-in relaysub-base type Output sub-base[Us] rated supply voltage 19...30 V conforming to IEC 61131-2number of channels 16connections - terminals Screw type terminals, 1 x 0.09...1 x 1.5 mm² (AWG 28...AWG 16) flexible with cable endScrew type terminals, 1 x 0.14...1 x 2.5 mm² (AWG 26...AWG 12) solidScrew type terminals, 1 x 0.14...1 x 2.5 mm² (AWG 26...AWG 14) flexible without cable endScrew type terminals, 2 x 0.09...2 x 0.75 mm² (AWG 28...AWG 20) flexible with cable endScrew type terminals, 2 x 0.2...2 x 2.5 mm² (AWG 24...AWG 14) solidchannel additional information 1 switch disconnector per channelComplementary supply voltage type DCproduct compatibility ABR7S2.ABS7SC2.ABE7ACC20ABS7SA2.status LED 1 LED per channel (green)channel status: 1 LED (green)power ON:polarity distribution Polarity distribution contact common per 2 groups of 8 channelsshort-circuit protection 1 A internal fuse, 5 x 20 mm, fast blow (PLC end)0.5 A fuse per channel, 5 x 20 mm, fast blow (output circuit)fixing mode By clips (35 mm symmetrical DIN rail)By screws (solid plate with fixing kit)maximum supply current 1 Avoltage drop on power supply fuse 0.3 Vmaximum current per output common 16 A[Ui] rated insulation voltage 300 V coil circuit/contact circuits conforming to IEC 60947-12000 V terminals/mounting rails[Uimp] rated impulse withstand voltage 2.5 kVinstallation category II conforming to IEC 60664-1tightening torque 0.6 N.m with flat Ø 3.5 mm screwdrivernet weight 0.67 kgEnvironment product certifications GLCSABVLROS (Lloyds register of shipping)DNVIP degree of protection IP2x conforming to IEC 60529resistance to incandescent wire 750 °C conforming to IEC 60695-2-11shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27vibration resistance 2 gn (f= 10…150 Hz) conforming to IEC 60068-2-6resistance to electrostatic discharge 4 kV (contact) level 3 conforming to IEC 61000-4-28 kV (air) level 3 conforming to IEC 61000-4-2resistance to radiated fields 10 V/m (26000000…1000000000 Hz) conforming to IEC 61000-4-3 level 3resistance to fast transients 2 kV level 3 conforming to IEC 61000-4-4ambient air temperature for operation -5…60 °C conforming to IEC 61131-2ambient air temperature for storage -40…80 °C conforming to IEC 61131-2pollution degree 2 conforming to IEC 60664-1Offer Sustainability Sustainable offer status Green Premium productREACh Regulation REACh free of SVHC YesEU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages69
- English11
- Chinese5
- French59
- German6
- Italian6
- Portuguese5
- Spanish6
CatalogueFormatSizeAdd to My DocumentsTelefast Pre-wired system : Modicon ABE7 IP20 connection sub-bases, Modicon ABE9 IP67 passive splitter boxes (Version 3.2)Size pdfSize 10.8 MBDate 10/4/19Système de précâblage Telefast, Embases de raccordement IP20 Modicon ABE7, Répartiteurs passifs IP67 Modicon ABE9 (Version 3.2)Size pdfSize 9 MBDate 10/3/19User guideFormatSizeAdd to My Documents使用 EcoStruxure™ Control Expert 的 Premium 和 Atrium - 离散量 I/O 模块 , 用户手册 (Version 09)Description本手册介绍了针对 Premium 和 Atrium PLC 的离散量模块的硬件和软件实施。Size pdfSize 5.1 MBDate 12/1/18Description本手册介绍了针对 Premium 和 Atrium PLC 的离散量模块的硬件和软件实施。Premium et Atrium sous EcoStruxure™ Control Expert - Modules d'E/S TOR, Manuel utilisateur (Version 10)DescriptionCe manuel présente la mise en oeuvre matérielle et logicielle des modules TOR pour automates Premium et Atrium.Size pdfSize 5.3 MBDate 12/1/18DescriptionCe manuel présente la mise en oeuvre matérielle et logicielle des modules TOR pour automates Premium et Atrium.Premium und Atrium unter EcoStruxure™ Control Expert - Digitale E/A-Module, Benutzerhandbuch (Version 12)DescriptionIn diesem Handbuch wird die Installation der digitalen Module (Hardware und Software) für Premium- und Atrium-Steuerungen beschrieben.Size pdfSize 5.5 MBDate 12/1/18DescriptionIn diesem Handbuch wird die Installation der digitalen Module (Hardware und Software) für Premium- und Atrium-Steuerungen beschrieben.Premium e Atrium con EcoStruxure™ Control Expert - Moduli di I/O digitali, Manuale dell’utente (Version 08)DescriptionIn questo manuale viene descritta l'implementazione hardware e software di moduli digitali per PLC Premium e Atrium.Size pdfSize 5.5 MBDate 12/1/18DescriptionIn questo manuale viene descritta l'implementazione hardware e software di moduli digitali per PLC Premium e Atrium.Premium y Atrium con EcoStruxure™ Control Expert - Módulos de E/S binarios, Manual de usuario (Version 12)DescriptionEn este manual se describe la instalación del hardware y el software de los módulos binarios para los PLC Premium y Atrium.Size pdfSize 5.4 MBDate 12/1/18DescriptionEn este manual se describe la instalación del hardware y el software de los módulos binarios para los PLC Premium y Atrium.CADFormatSizeAdd to My DocumentsSize zipSize 343.8 KBDate 1/13/05Size zipSize 253.6 KBDate 1/13/05Instruction sheetFormatSizeAdd to My DocumentsABE7P16T2... Sub-bases for solid state and/or electromechanical output relays, plug-in (Version 05)DescriptionNoneSize pdfSize 814.4 KBDate 8/1/02DescriptionNoneCatalogue pageFormatSizeAdd to My DocumentsSize pdfSize 641.8 KBDate 2/27/18Size pdfSize 368.9 KBDate 3/24/16Size pdfSize 234.7 KBDate 2/1/16Modicon Quantum - Architectures Ethernet I/O : présentation, description, architectures, références (Version 3.1)Size pdfSize 2.4 MBDate 2/1/16Modicon Quantum - Modules de comptage et modules spécifiques : présentation / description / références (Version 2.1)Size pdfSize 252.7 KBDate 2/1/16Modicon Quantum - Pocesseurs avec port Ethernet et coupleurs réseau Ethernet : présentation /description /références (Version 3.0)Size pdfSize 88.6 KBDate 2/1/16Plates-formes d'automatisme Modicon - Architectures Ethernet PlantStruxure : serveurs et passerelles Web FactoryCast (Version 8.1)Size pdfSize 121.6 KBDate 2/1/16Plates-formes d'automatisme Modicon - Architectures Ethernet PlantStruxure : services Web actif FactoryCast HM (Version 6.1)Size pdfSize 522.4 KBDate 2/1/16Size pdfSize 431.1 KBDate 2/1/16Size pdfSize 496.6 KBDate 2/1/16Size pdfSize 587.3 KBDate 2/1/16Size pdfSize 329.6 KBDate 2/1/16Size pdfSize 198.1 KBDate 2/1/16Size pdfSize 342.2 KBDate 2/1/16Size pdfSize 521.5 KBDate 2/1/16Plates-formes d'automatisme Modicon - Architectures Ethernet PlantStruxure : services Web de base (Version 8.0)Size pdfSize 255.1 KBDate 2/1/16Size pdfSize 290.3 KBDate 2/1/16Plates-formes d'automatisme Modicon - Réseaux EtherNet/IP et Modbus/TCP : performances (Version 6.0)Size pdfSize 174.6 KBDate 2/1/16Size pdfSize 114.8 KBDate 2/1/16Modicon Quantum - Architectures d'E/S (bus S908) : présentation / description / référence (Version 5.0)Size pdfSize 489.8 KBDate 2/1/16Size pdfSize 158.9 KBDate 2/1/16Size pdfSize 133.9 KBDate 2/1/16Size pdfSize 228.2 KBDate 2/1/16Size pdfSize 303.7 KBDate 2/1/16Modicon Quantum - Modules d'entrées/sorties TOR : présentation / description / références (Version 2.1)Size pdfSize 244.2 KBDate 2/1/16Modicon Quantum - Modules d'entrées/sorties analogiques : présentation / description / références (Version 2.1)Size pdfSize 120.2 KBDate 2/1/16Modicon Quantum - AS-Interface, coupleur maitre : présentation /description /références (Version 2.1)Size pdfSize 66.7 KBDate 2/1/16Plates-formes d'automatisme Modicon Quantum- Réseaux EtherNet/IP et Modbus/TCP : characterists (Version 1.0)Size pdfSize 98.9 KBDate 2/1/16Size pdfSize 158 KBDate 2/1/16Size pdfSize 210.4 KBDate 2/1/16Size pdfSize 45.1 KBDate 2/1/16Size pdfSize 1,009.1 KBDate 2/1/16Size pdfSize 76.4 KBDate 2/1/16Size pdfSize 67.6 KBDate 2/1/16Size pdfSize 210.3 KBDate 2/1/16Modicon Quantum - Sytème Hot Standby (Unity Pro) : presentation / description / reference (Version 2.1)Size pdfSize 479.7 KBDate 2/1/16Modicon Quantum - Module réseau EtherNet/IP et Modbus/TCP : présentation /description /références (Version 2.1)Size pdfSize 179.5 KBDate 2/1/16Size pdfSize 205.5 KBDate 2/1/16Plates-formes d'automatisme Modicon - Architectures Ethernet PlantStruxure : services Web SOAP/XML (Version 7.1)Size pdfSize 81.1 KBDate 2/1/16Laison série - Module de liaison série asynchrone : présentation / description / références (Version 2.1)Size pdfSize 63.1 KBDate 2/1/16Size pdfSize 225.6 KBDate 2/1/16Size pdfSize 246.3 KBDate 2/1/16Declaration of conformityFormatSizeAdd to My DocumentsSize pdfSize 1.7 MBDate 1/25/17End of Life InformationFormatSizeAdd to My DocumentsSize pdfSize 442.1 KBDate 8/1/16Size pdfSize 267.8 KBDate 11/1/11EU RoHS DeclarationFormatSizeAdd to My Documentssub-base for plug-in relay ABE7 - 16 channels - fuses - relay 10 mmDescriptionsub-base for plug-in relay ABE7 - 16 channels - fuses - relay 10 mmSize pdfSize 195.3 KBDate 12/6/19Descriptionsub-base for plug-in relay ABE7 - 16 channels - fuses - relay 10 mmMarine certificateFormatSizeAdd to My DocumentsREACh DeclarationFormatSizeAdd to My Documentssub-base for plug-in relay ABE7 - 16 channels - fuses - relay 10 mmDescriptionsub-base for plug-in relay ABE7 - 16 channels - fuses - relay 10 mmSize pdfSize 195.3 KBDate 12/6/19Descriptionsub-base for plug-in relay ABE7 - 16 channels - fuses - relay 10 mmChina RoHS declarationFormatSizeAdd to My Documentssub-base for plug-in relay ABE7 - 16 channels - fuses - relay 10 mmDescriptionsub-base for plug-in relay ABE7 - 16 channels - fuses - relay 10 mmSize pdfSize 195.3 KBDate 12/6/19Descriptionsub-base for plug-in relay ABE7 - 16 channels - fuses - relay 10 mm -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
Dimensions(1)ABE7BV10 / BV20, ABE7BV10E / BV20E -
Mounting and Clearance
Mounting -
Connections and Schema
HE10 16 ChannelsWiring Diagram(1)Inductive load(2)Fuse only for ABE7P16T215(3)ABR7S21 (1 “F”/SPDT) (not supplied)(4)ABS7SC2E (5...48 VDC) I max. = 0.5 A (not supplied)(5)ABS7SA2M (24...240 VAC) I max. = 0.5 A (not supplied)Wiring Diagram with ABE7ACC20(1)Inductive load(2)Fuse only for ABE7P16T215(3)ABR7S21 (1 “F”/SPDT) (not supplied)(4)ABS7SC2E (5...48 VDC) I max. = 0.5 A (not supplied)(6)ABE7ACC20 (24 VDC) (not supplied/not isolated) -
Performance Curves
Curves for Determining Cable Type and Length According to the Current16-channel Sub-baseLCable lengthITTotal current per sub base (A)IAAverage current per channel (mA)(1)TSXCDP••2 and ABFH20H••0 cables with c.s.a. 0.08 mm2 (AWG 28).(2)TSXCDP••3 cables with c.s.a. 0.34 mm2 (AWG 22).(3)Cables with c.s.a. 0.13 mm2 (AWG 26).The curves are given for a voltage drop of 1 V in the cable. For n volts tolerance, multiply the length determined from the graph by n.