Welcome to the Schneider Electric corporate Website

Select your location

View all   Modicon ABE7
Schneider Electric ABE7R16S111 Image

ABE7R16S111

Green premium brand logo
Schneider Electric ABE7R16S111 Image
ABE7R16S111
Green premium brand logo

sub-base - soldered electromechanical relays ABE7 - 16 channels - relay 5 mm

Show more characteristics
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range of product
    Modicon ABE7
    product or component type
    Electromechanical output relay sub-base
    [Us] rated supply voltage
    24 V DC for PLC end
    number of channels
    16
    number of terminal per channel
    1
    Complementary
    terminal block type
    Removable
    polarity distribution
    Polarity distribution contact common per group of 8 channels
    fixing mode
    By clips (35 mm symmetrical DIN rail)
    By screws (solid plate with fixing kit)
    width
    125 mm
    maximum current per output common
    12 A
    current per channel
    2 A for preactuator end
    minimum switching current
    1 mA at >= 5 V
    drop-out voltage
    2.4 V at 20 °C (PLC end)
    switching frequency
    <= 10 Hz
    <= 0.5 Hz
    threshold tripping voltage
    19.2 V at 40 °C
    drop-out current
    0.5 mA at 20 °C
    maximum power dissipation per channel in W
    0.22 W (PLC end)
    contacts type and composition
    1 NO for preactuator end
    maximum switching voltage
    250 V AC 50/60 Hz conforming to IEC 60947-5-1
    30 V DC conforming to IEC 60947-5-1
    number of channel per common
    8
    electrical durability
    500000 cycles, maximum switching current: 200 mA at 24 V DC-13 10 ms (preactuator end)
    500000 cycles, maximum switching current: 400 mA at 230 V AC-15 (preactuator end)
    500000 cycles, maximum switching current: 600 mA at 230 V AC-12 (preactuator end)
    500000 cycles, maximum switching current: 600 mA at 24 V DC-12 (preactuator end)
    electrical reliability
    1e-008
    operating time
    <= 10 ms coil energisation and NO closing
    <= 6 ms coil de-energisation and NO opening
    contact bounce time
    <= 5 ms 1 NO
    operating rate in Hz
    10 Hz no load
    0.5 Hz at Ie
    mechanical durability
    20000000 cycles
    [Uimp] rated impulse withstand voltage
    2.5 kV IEC 60947-1
    [Ui] rated insulation voltage
    2000 V
    installation category
    II conforming to IEC 60664-1
    tightening torque
    0.6 N.m with flat Ø 3.5 mm screwdriver
    net weight
    0.405 kg
    Environment
    max immunity to microbreaks
    5 ms
    dielectric strength
    2000 V conforming to IEC 60947-1
    product certifications
    DNV
    UL
    CSA
    GL
    BV
    LROS (Lloyds register of shipping)
    IP degree of protection
    IP2x conforming to IEC 60529
    protective treatment
    TC
    resistance to incandescent wire
    750 °C, extinction time <30 s conforming to IEC 60695-2-11
    shock resistance
    15 gn for 11 ms conforming to IEC 60068-2-27
    resistance to radiated fields
    10 V/m (26000000…1000000000 Hz) conforming to IEC 61000-4-3 level 3
    resistance to fast transients
    2 kV level 3 conforming to IEC 61000-4-4
    ambient air temperature for operation
    -5…60 °C conforming to IEC 61131-2
    ambient air temperature for storage
    -40…80 °C conforming to IEC 61131-2
    pollution degree
    2 conforming to IEC 60664-1
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    REACh free of SVHC
    Yes
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages12
    • English11
    • French6
    • German5
    • Italian5
    • Portuguese5
    • Spanish5
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 10.8 MB
    Date 1/20/20
    CAD
    Format
    Size
    Date
    Add to My Documents
    Premium automation platform - Telefast 2 - Sub-bases (Version 1.0)
    Files in document
    dxf
    168 KB
    dwf
    1.3 KB
    wmf
    7.7 KB
    dwg
    76.6 KB
    prp.document.label.format zip
    Size 253.7 KB
    Date 1/13/05
    Files in document
    dxf
    168 KB
    dwf
    1.3 KB
    wmf
    7.7 KB
    dwg
    76.6 KB
    Premium automation platform - Telefast 2 - Sub-bases (Version 1.0)
    Files in document
    dwg
    85 KB
    dxf
    193.7 KB
    dwf
    2 KB
    wmf
    44.3 KB
    prp.document.label.format zip
    Size 324.9 KB
    Date 1/13/05
    Files in document
    dwg
    85 KB
    dxf
    193.7 KB
    dwf
    2 KB
    wmf
    44.3 KB
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 1.4 MB
    Date 5/1/02
    Description
    None
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    ABE7R16S111 : sub-base - soldered electromechanical relays ABE7 - 16 channels - relay 5 mm
    Description
    sub-base - soldered electromechanical relays ABE7 - 16 channels - relay 5 mm
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/26/20
    Description
    sub-base - soldered electromechanical relays ABE7 - 16 channels - relay 5 mm
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 1.7 MB
    Date 1/25/17
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 442.1 KB
    Date 8/1/16
    prp.document.label.format pdf
    Size 267.8 KB
    Date 11/1/11
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    ABE7R16S111 : sub-base - soldered electromechanical relays ABE7 - 16 channels - relay 5 mm
    Description
    sub-base - soldered electromechanical relays ABE7 - 16 channels - relay 5 mm
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/26/20
    Description
    sub-base - soldered electromechanical relays ABE7 - 16 channels - relay 5 mm
    Marine certificate
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 80.5 KB
    Date 5/19/16
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    ABE7R16S111 : sub-base - soldered electromechanical relays ABE7 - 16 channels - relay 5 mm
    Description
    sub-base - soldered electromechanical relays ABE7 - 16 channels - relay 5 mm
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/26/20
    Description
    sub-base - soldered electromechanical relays ABE7 - 16 channels - relay 5 mm
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions


    (1)
    ABE7BV20 / ABE7BV20E

    ABE7

    a in mm

    a in in.

    R16S111 / R16S111E

    125

    4.92

    R16S21 / R16S21•E

    206

    8.11


  • Mounting and Clearance

    Mounting



  • Connections and Schema

    HE10 16 Channels



    Wiring Diagram


    (1)
    Inductive load


  • Performance Curves

    Curves for Determining Cable Type and Length According to the Current
    16-channel Sub-base


    L
    Cable length
    IT
    Total current per sub base (A)
    IA
    Average current per channel (mA)
    (1)
    TSXCDP••2 and ABFH20H••0 cables with c.s.a. 0.08 mm2 (AWG 28).
    (2)
    TSXCDP••3 cables with c.s.a. 0.34 mm2 (AWG 22).
    (3)
    Cables with c.s.a. 0.13 mm2 (AWG 26).

    The curves are given for a voltage drop of 1 V in the cable. For n volts tolerance, multiply the length determined from the graph by n.


    Temperature Derating Curves


    (1)
    100 % of channels used
    (2)
    50 % of channels used


    Electrical Durability (in Millions of Operating Cycles) Conforming to IEC 60947-5-1
    DC Loads

    DC12 curves


    DC12
    control of resistive loads and of solid state loads isolated by optocoupler, l/R ≤ 1 ms.

    DC13 curves


    DC13
    switching electromagnets, L/R ≤ 2 x (Ue x Ie) in ms, Ue: rated operational voltage, Ie: rated operational current (with a protective diode on the load, DC12 curves must be used with a coefficient of 0.9 applied to the number in millions of operating cycles)

    AC Loads

    AC12 curves


    AC12
    control of resistive loads and of solid state loads isolated by optocoupler, cos ϕ ≥ 0.9.

    AC14 curves


    AC14
    control of small electromagnetic loads ≤ 72 VA, make: cos ϕ = 0.3, break: cos ϕ = 0.3.

    AC15 curves


    AC15
    control of electromagnetic loads > 72 VA, make: cos ϕ = 0.7, break: cos ϕ = 0.4.