Welcome to the Schneider Electric corporate Website

Select your location

View all   Linergy HK
Schneider Electric AK5JB149 Image

AK5JB149

Green premium brand logo
Schneider Electric AK5JB149 Image
AK5JB149
Green premium brand logo

BUS BAR TRI N 160ALG988MM

Show more characteristics
The maximum number of products that can be compared is 4

  • Main
    range
    Linergy
    product name
    HK
    product or component type
    Busbar
    device application
    Distribution
    Tap-offs (18 mm)
    48
    bar length
    992 mm
    enclosure/cubicle width
    1200 mm
    network type
    AC
    [Ie] rated operational current
    160 A at 35 °C
    [Ue] rated operational voltage
    400 V (off-load plugging-in and unplugging, with supply switched on) conforming to IEC 60439-1
    480 V (off-load plugging-in and unplugging, with supply switched on) conforming to CSA
    480 V (off-load plugging-in and unplugging, with supply switched on) conforming to UL
    600 V (plugging-in and unplugging, with supply switched off) conforming to CSA
    600 V (plugging-in and unplugging, with supply switched off) conforming to UL
    690 V (plugging-in and unplugging, with supply switched off) conforming to IEC 60439-1
    number of conductors
    4
    Complementary
    bar width
    40 mm
    width
    80 mm
    depth
    84 mm
    network frequency
    50/60 Hz
    [Ui] rated insulation voltage
    600 V conforming to CSA
    600 V conforming to UL
    690 V conforming to IEC 60439-1
    peak current
    25 kA
    I²t on activation
    10000000 A².s
    protection type
    AM fuses In = 160 A, Isc = 100 kA, Ie = 160 A
    GF fuses In = 160 A, Isc = 100 kA, Ie = 160 A
    NS160H circuit breaker In = 160 A, Isc = 36 kA, Ie = 160 A
    NS160H circuit breaker In = 160 A, Isc = 70 kA, Ie = 160 A
    connections - terminals
    Connector 2.5…70 mm² flexible with cable end
    Connector 2.5…70 mm² rigid
    tightening torque
    10 N.m
    mounting position
    Vertical mounting using side stop AK5BT01 on mounting plates AK5PA
    Horizontal mounting
    flame retardance
    V0 conforming to UL 94
    net weight
    1.9 kg
    Environment
    standards
    IEC 60439
    product certifications
    DNV
    CSA
    LROS (Lloyds register of shipping)
    UL
    IP degree of protection
    IPxx B conforming to IEC 60529
    fire resistance
    850 °C conforming to IEC 60695
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    EU RoHS Directive
    Toxic heavy metal free
    Yes
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
     Pro-active China RoHS declaration (out of China RoHS legal scope)
    Environmental Disclosure
    Circularity Profile
    No need of specific recycling operations
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages10
    • English8
    • Chinese2
    • French4
    • German2
    • Italian2
    • Portuguese2
    • Russian2
    • Spanish2
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    Linergy - Distribution and connection systems catalogue - English (Version 3.0)
    Description
    Distribution and connection systems catalogue
    prp.document.label.format pdf
    Size 82.2 MB
    Date 10/10/19
    Description
    Distribution and connection systems catalogue
    Tesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)
    Description
    Ready-to-use motor starters and all components for building specific motor starters ( circuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.
    prp.document.label.format pdf
    Size 111.5 MB
    Date 7/12/19
    Description
    Ready-to-use motor starters and all components for building specific motor starters ( circuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.
    TeSys catalogue - 2019 - 2020 - chapter B1 Linergy BZ & HK power busbar systems (Version 7.0)
    Description
    Linergy BZ and HK busbar systems for electrical distribution in panelboards and control cabinets. Adapted to circuit rpection and feeding, as well as motor starters on mounting plates.
    prp.document.label.format pdf
    Size 4.6 MB
    Date 5/15/19
    Description
    Linergy BZ and HK busbar systems for electrical distribution in panelboards and control cabinets. Adapted to circuit rpection and feeding, as well as motor starters on mounting plates.
    Catalogue TeSys 2019 - Composants pour protection et commande de moteurs (Version 7.1)
    Description
    Le catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.
    prp.document.label.format pdf
    Size 108.2 MB
    Date 7/12/19
    Description
    Le catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.
    Catalogue TeSys 2019 - Chapitre B1- Systèmes de jeux de barres Linergy BZ HK (Version 4.0)
    Description
    Présentation du système Linergy BZ : barres nues jusquà 630 A avec platines enclipsables pour disjoncteurs de distribution électrique et démarreurs-moteurs.Présentation du système Linergy HK : barres-répartiteurs isolés jusquà 160 A avec platines enbrochables pour disjoncteurs de distribution électrique et démarreurs-moteurs. Embrochage/débrochage possible sous tension.
    prp.document.label.format pdf
    Size 5.6 MB
    Date 6/11/19
    Description
    Présentation du système Linergy BZ : barres nues jusquà 630 A avec platines enclipsables pour disjoncteurs de distribution électrique et démarreurs-moteurs.Présentation du système Linergy HK : barres-répartiteurs isolés jusquà 160 A avec platines enbrochables pour disjoncteurs de distribution électrique et démarreurs-moteurs. Embrochage/débrochage possible sous tension.
    CAD
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format zip
    Size 682.9 KB
    Date 10/15/13
    Files in document
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 3.3 MB
    Date 12/21/18
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    AK5JB149 : BUS BAR TRI N 160ALG988MM
    Description
    BUS BAR TRI N 160ALG988MM
    prp.document.label.format pdf
    Size 195.3 KB
    Date 2/27/20
    Description
    BUS BAR TRI N 160ALG988MM
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    AK5JB149 : BUS BAR TRI N 160ALG988MM
    Description
    BUS BAR TRI N 160ALG988MM
    prp.document.label.format pdf
    Size 195.3 KB
    Date 2/27/20
    Description
    BUS BAR TRI N 160ALG988MM
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    AK5JB149 : BUS BAR TRI N 160ALG988MM
    Description
    BUS BAR TRI N 160ALG988MM
    prp.document.label.format pdf
    Size 195.3 KB
    Date 2/27/20
    Description
    BUS BAR TRI N 160ALG988MM
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.