View all
Altivar 11

ATV11PU09F1A
ATV11PU09F1A
variable speed drive ATV11 - 0.37kW - 120V 1-phase supply - IP20
Show more characteristics
ATV11PU09F1A is replaced by:
Product
Qty
-
Characteristics
Main range of product Altivarproduct or component type Variable speed driveproduct specific application Simple machinecomponent name ATV11application market Asiamounting support Base plateEMC filter Without EMC filterbuilt-in fan Withoutnetwork number of phases Single phase[Us] rated supply voltage 100...120 V - 15...10 %supply frequency 50...60 Hz - 5...5 %motor power kW 0.37 kWline current 9 A at 100 V, Isc = 1 kAnominal output current 1.4 A 230 V motor 4 kHzmaximum transient current 3.6 A for 60 spower dissipation in W 25 W at nominal loadswitching frequency 2...16 kHz adjustable4...16 kHz with derating factorbraking torque 150 % of nominal motor torque with braking resistor at high inertia20 % of nominal motor torque without braking resistor at no load80 % of nominal motor torque with braking resistor at no loadasynchronous motor control profile Sensorless flux vector control with PWM type motor control signalelectrical connection Terminal, clamping capacity: 1.5 mm², AWG 14 (AI1, RA-RC, LI1...LI4, DO)Terminal, clamping capacity: 1.5 mm², AWG 14 (L1, L2, L3, U, V, W, PA, PC)supply Internal supply for logic inputs: 15 V (+/- 15 %) 100 mA, protection type: overload and short-circuit protectionInternal supply for reference potentiometer (2.2 to 10 kOhm): 5...5.25 VDC 10 mA, protection type: overload and short-circuit protectionanalogue input type Configurable current AI1 4...20 mA 250 Ohm without adding resistorConfigurable voltage AI1 0...5 V 40000 Ohm only with internal supplyConfigurable current AI1 0...20 mA 250 OhmConfigurable voltage AI1 0...10 V 40000 Ohmsampling duration AI1: 20 ms analogLI1...LI4: 20 ms discreteresponse time 20 ms DOlinearity error DO: +/- 1 % for outputAI: +/- 5 % for inputdiscrete input type Assignable Ll1 forward 5000 Ohm 15 V 24 VAssignable Ll2 reverse 5000 Ohm 15 V 24 VAssignable Ll3/Ll4 4 preset speeds 5000 Ohm 15 V 24 Vdiscrete input logic Positive logic (source) (LI1...LI4), < 5 V (state 0), > 11 V (state 1)Logic input not wired (LI1...LI4), < 5 V (state 1)Negative logic (source) (LI1...LI4), > 11 V (state 0)discrete output type Assignable as external voltage DO 30 V max, 30 mAAssignable as open collector logic output DO 100 Ohm, 50 mA maxFactory set as PWM open collector output DO at 2 kHz 10 mA maxProtected relay logic RA-RC 1 NOAssignable as internal voltage DOminimum switching current RA-RC 10 mA at 24 V DCmaximum switching current 2 A 250 V AC inductive cos phi = 0.4 7 ms RA-RC2 A 30 V DC inductive cos phi = 0.4 7 ms RA-RC5 A 250 V AC resistive cos phi = 1 RA-RC5 A 30 V DC resistive cos phi = 1 RA-RCprotection type Line supply overvoltage: driveLine supply undervoltage: driveOvercurrent between output phases and earth: driveOverheating protection: driveShort-circuit between motor phases: driveThermal protection: motorfrequency resolution Display unit: 0.1 HzAnalog input: converter A/D, 10 bitselectromagnetic compatibility 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to EN/IEC 61000-4-5Electrical fast transient/burst immunity test level 4 conforming to EN/IEC 61000-4-4Electrostatic discharge immunity test level 3 conforming to EN/IEC 61000-4-2Radiated radio-frequency electromagnetic field immunity test level 3 conforming to EN/IEC 61000-4-3maximum motor cable length 20 m with additional EMC filter from 2 to 16 kHz conforming to EN 55011 class A group 15 m with additional EMC filter from 2 to 16 kHz conforming to EN 55011 class Bvibration resistance 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-61.5 mm peak to peak (f= 3…13 Hz) conforming to EN/IEC 60068-2-6shock resistance 15 gn for 11 ms conforming to EN/IEC 60068-2-27relative humidity 5…93 % without condensation conforming to IEC 60068-2-35…93 % without dripping water conforming to IEC 60068-2-3ambient air temperature for operation -10…40 °C without40…50 °C by removing the protective cover from the top of the drive50…60 °C by removing the protective cover from the top of the drive with current derating of 2.2 % per °Coperating altitude <= 1000 m without> 1000 m with current derating 1 % per 100 mComplementary product destination Asynchronous motorssupply voltage limits 85…130 Vnetwork frequency limits 47.5…63 Hzspeed drive output frequency 0…200 Hznominal switching frequency 4 kHzspeed range 1…20transient overtorque 150...170 % of nominal motor torqueregulation loop Factory-set with the speed loop stability and gainAdjustable frequencyPossible correction for machines with high resistive torque/inertia/fast cyclesmotor slip compensation AdjustablePreset in factoryprospective line Isc 1 kAoutput voltage <= 2 x power supply voltageinsulation Electrical between power and controlanalogue input number 1discrete input number 4discrete output number 2acceleration and deceleration ramps Linear from 0 to 99.9 sbraking to standstill By DC injectioninsulation resistance > 500 MOhmmarking CEoperating position Vertical +/- 10 degreeCAD overall width 72 mmCAD overall height 142 mmCAD overall depth 108 mmnet weight 0.9 kgEnvironment standards EN 50178product certifications ULCSAC-TickN998IP degree of protection IP20ambient air temperature for storage -25…65 °CContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages7
- English7
- French7
- German7
- Italian7
- Spanish7
User guideFormatSizeAdd to My DocumentsATV11 Technical manual (Version 4)DescriptionVariable speed controllers for asynchronous motorsSize pdfSize 8.9 MBDate 9/1/06DescriptionVariable speed controllers for asynchronous motorsAltivar 11 ATV11 User Manual (Version 5)DescriptionAltivar ATV11...A VFD / VSD variable speed drive controllers for asynchronous motors. This document includes information on setting up the drive, connections, configurations, start up. Also includes dimensions, mounting the drive, wiring diagrams, keypad functions, menu logic, and troubleshooting.Size pdfSize 1.5 MBDate 9/1/06DescriptionAltivar ATV11...A VFD / VSD variable speed drive controllers for asynchronous motors. This document includes information on setting up the drive, connections, configurations, start up. Also includes dimensions, mounting the drive, wiring diagrams, keypad functions, menu logic, and troubleshooting.CADFormatSizeAdd to My DocumentsVariable speed drive ATV11 with heatsink or base plate (Version 1.0)Files in documentSize zipSize 422.7 KBDate 11/8/07Files in documentVariable speed drive ATV11 with heatsink or base plate (Version 1.0)Files in documentSize zipSize 1.1 MBDate 11/8/07Files in documentVariable speed drive ATV11 with heatsink or base plate (Version 1.0)Files in documentSize zipSize 351.6 KBDate 11/8/07Files in documentVariable speed drive ATV11 with heatsink or base plate (Version 1.0)Files in documentSize zipSize 431 KBDate 11/8/07Files in documentInstruction sheetFormatSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.