View all
Altivar 1200

ATV1200A14003333
ATV1200A14003333
medium voltage variable speed drive ATV1200 - 3.3 kV - 1400 kVA
Show more characteristics-
Characteristics
Main range of product Altivar 1200product or component type Medium voltage variable speed drivedevice short name ATV1200product destination Asynchronous motorsSynchronous motorsproduct specific application Fan, pump, compressor, conveyorassembly style In floor-standing enclosure with separate air flowsComplementary product composition 2 x plinthPhase-shifting transformer9 x power cellsMedium voltage arrestorsCooling fansHuman machine interfaceEMC filter Integratednetwork number of phases 3 phasesinput type 18 pulse diode rectifier bridge[Us] rated supply voltage 3.3 kV +/- 10 %supply voltage limits 2970…3630 V[Uc] control circuit voltage 220 Vmotor power kW 1170 kWline current 280 Adrive efficiency with transformer (including fan power) 96 % (standard efficiency)96.5 % (high efficiency)total losses at 100 % load including fan power 47 kW (standard efficiency)41 kW (high efficiency)apparent power 1400 kVAprospective line Isc 31.5 kA for 150 msoverload withstand 1.2 In, standard overload, 60 s1.5 In, standard overload, 3 s1.5 In, high overload, 60 s1.85 In, high overload, 3 scontinuous output current 245 A (standard overload)196 A (high overload)maximum transient current 294 A for 60 sspeed drive output frequency 0.5…120 Hz voltage/frequency ratio (V/f)0.5…70 Hz vector control with/without speed feedbacknominal switching frequency 600 Hzspeed range 20…100asynchronous motor control profile Voltage/frequency ratio (V/f)Closed-loop control with encoderVector control with sensor, optionalSensorless flux vector controlsynchronous motor control profile Voltage/frequency ratio (V/f)Closed-loop control with encoderovervoltage category II conforming to EN/IEC 61800-5-1output voltage <= power supply voltageisolation Electrical between power and controlelectrical connection Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the topsupply External supply for control at 220 V AC, 3 kVAInternal supply for cooling fan at 380 V ACExternal supply for control at 220 V AC/DC (optional)External supply for cooling fan at 380 V AC (optional)analogue input number 4analogue input type software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohmanalogue output number 24 (optional)analogue output type software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohmdiscrete output number 1014 (optional)discrete input number 610 (optional)acceleration and deceleration ramps Linear from 0...3200 sprotection type Ground fault protection: drivedielectric strength 10 kV AC between earth and power terminalscommunication port protocol Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9Human machine interface: Modbus TCP with (1) - RJ45Human machine interface: Ethernet/IP with (1) - RJ45Human machine interface: Profibus with (1) - SUB-D 9Human machine interface: DeviceNet with (1) - SUB-D 9operating position Vertical +/- 10 degreecolour of enclosure Grey (RAL 7032)width 3560 mm (standard efficiency)3860 mm (high efficiency)depth 1400 mm (standard efficiency)1600 mm (high efficiency)height 2820 mm standard efficiency2820 mm high efficiencynet weight 5000 kg (standard efficiency)6100 kg (high efficiency)Environment IP degree of protection IP42IP41IP31standards EN/IEC 60204-11EN/IEC 60529EN/IEC 61800-3EN/IEC 61800-4EN/IEC 61800-5-1IEEE 519:1992marking CEpollution degree 2 conforming to EN/IEC 61800-5-1noise level 80 dBvibration resistance 4.9 m/s² (f= 10…50 Hz)relative humidity 0…90 %0…95 % optionalambient air temperature for operation 0…40 °C40…50 °C (with current derating of 2 % per °C)ambient air temperature for storage -10…60 °Cvolume of cooling air 29900 m3/h (standard efficiency)33200 m3/h (high efficiency)type of cooling Forced convectionoperating altitude <= 1000 m without1000...2000 m with current derating 0.6 % per 100 m -
View more
Documents
Language- Italian5
User guideFormatSizeAdd to My DocumentsSize pdfSize 4.8 MBDate 2/1/17Size pdfSize 4.8 MBDate 2/1/17Size pdfSize 3.6 MBDate 2/1/17 -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
DimensionsStandard EfficiencyHigh Efficiency -
Mounting and Clearance
Clearance -
Connections and Schema
Connections and SchemaStandard Wiring Diagram(1)Integrated power supply(2)Control power supply(3)4-20mA speed setpoint(4)Input reserved(5)VFD is ready(6)Local 1 remote control(7)VFD running(8)Alarming(9)Detected fault(10)4-20mA Output current(11)4-20mA Output speed(12)Stop(13)Start(14)Main circuit breaker enable to close(15)Trip main circuit breaker(16)Undervoltage release module of circuit breaker(17)4-20mA reserved inputs(18)Reserved outputs(QF1)Main circuit breaker -
Performance Curves
Power Derating of Output CurrentTemperature Derating(x)Ambient temperature(y)DeratingAltitude Derating(x)Altitude(y)Derating