View all
Altivar 12

ATV12P037F1
ATV12P037F1
variable speed drive ATV12 - 0.37kW - 0.55hp - 100..120V - 1ph - on base plate
Show more characteristics-
Characteristics
Main range of product Altivar 12product or component type Variable speed driveproduct destination Asynchronous motorsproduct specific application Simple machineassembly style On base platecomponent name ATV12quantity per set Set of 1EMC filter Without EMC filterbuilt-in fan Withoutnetwork number of phases 1 phase[Us] rated supply voltage 100...120 V - 15...10 %motor power kW 0.37 kWmotor power hp 0.55 hpcommunication port protocol Modbusline current 11.4 A at 100 V9.3 A at 120 Vspeed range 1…20transient overtorque 150…170 % of nominal motor torque depending on drive rating and type of motorasynchronous motor control profile Quadratic voltage/frequency ratioVoltage/frequency ratio (V/f)Sensorless flux vector controlIP degree of protection IP20 without blanking plate on upper partnoise level 0 dBComplementary supply frequency 50/60 Hz +/- 5 %connector type 1 RJ45 (on front face) for Modbusphysical interface 2-wire RS 485 for Modbustransmission frame RTU for Modbustransmission rate 4800 bit/s9600 bit/s19200 bit/s38400 bit/snumber of addresses 1…247 for Modbuscommunication service Read holding registers (03) 29 wordsWrite single register (06) 29 wordsWrite multiple registers (16) 27 wordsRead/write multiple registers (23) 4/4 wordsRead device identification (43)prospective line Isc 1 kAcontinuous output current 2.4 A at 4 kHzmaximum transient current 3.6 A for 60 sspeed drive output frequency 0.5…400 Hznominal switching frequency 4 kHzswitching frequency 2...16 kHz adjustable4...16 kHz with derating factorbraking torque Up to 70 % of nominal motor torque without braking resistormotor slip compensation AdjustablePreset in factoryoutput voltage 200...240 V 3 phaseselectrical connection Terminal, clamping capacity: 3.5 mm², AWG 12 (L1, L2, L3, U, V, W, PA, PC)tightening torque 0.8 N.minsulation Electrical between power and controlsupply Internal supply for reference potentiometer: 5 V DC (4.75…5.25 V), <10 mA, protection type: overload and short-circuit protectionInternal supply for logic inputs: 24 V DC (20.4…28.8 V), <100 mA, protection type: overload and short-circuit protectionanalogue input number 1analogue input type Configurable current AI1 0...20 mA 250 OhmConfigurable voltage AI1 0...10 V 30 kOhmConfigurable voltage AI1 0...5 V 30 kOhmdiscrete input number 4discrete input type Programmable LI1...LI4 24 V 18...30 Vdiscrete input logic Negative logic (sink), > 16 V (state 0), < 10 V (state 1), input impedance 3.5 kOhmPositive logic (source), 0...< 5 V (state 0), > 11 V (state 1)sampling duration 20 ms, tolerance +/- 1 ms for logic input10 ms for analogue inputlinearity error +/- 0.3 % of maximum value for analogue inputanalogue output number 1analogue output type AO1 software-configurable voltage: 0...10 V, impedance: 470 Ohm, resolution 8 bitsAO1 software-configurable current: 0...20 mA, impedance: 800 Ohm, resolution 8 bitsdiscrete output number 2discrete output type Logic output LO+, LO-Protected relay output R1A, R1B, R1C 1 C/Ominimum switching current 5 mA at 24 V DC for logic relaymaximum switching current 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms logic relay2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms logic relay3 A 250 V AC resistive cos phi = 1 L/R = 0 ms logic relay4 A 30 V DC resistive cos phi = 1 L/R = 0 ms logic relayacceleration and deceleration ramps SLinear from 0 to 999.9 sUbraking to standstill By DC injection, <30 sprotection type Line supply overvoltageLine supply undervoltageOvercurrent between output phases and earthOverheating protectionShort-circuit between motor phasesAgainst input phase loss in three-phaseThermal motor protection via the drive by continuous calculation of I²tfrequency resolution Analog input: converter A/D, 10 bitsDisplay unit: 0.1 Hztime constant 20 ms +/- 1 ms for reference changemarking CEoperating position Vertical +/- 10 degreeheight 143 mmwidth 72 mmdepth 102.2 mmnet weight 0.7 kgVariable speed drive application selection Mixer Commercial equipmentOther application Commercial equipmentIroning Textilemotor starter type Variable speed driveEnvironment electromagnetic compatibility Electrical fast transient/burst immunity test level 4 conforming to EN/IEC 61000-4-4Electrostatic discharge immunity test level 3 conforming to EN/IEC 61000-4-2Immunity to conducted disturbances level 3 conforming to EN/IEC 61000-4-6Radiated radio-frequency electromagnetic field immunity test level 3 conforming to EN/IEC 61000-4-3Surge immunity test level 3 conforming to EN/IEC 61000-4-5Voltage dips and interruptions immunity test conforming to EN/IEC 61000-4-11electromagnetic emission Radiated emissions environment 1 category C2 conforming to EN/IEC 61800-3 2...16 kHz shielded motor cableConducted emissions with additional EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 4...12 kHz shielded motor cable <5 mConducted emissions with additional EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 4...12 kHz shielded motor cable <20 mConducted emissions with additional EMC filter environment 2 category C3 conforming to EN/IEC 61800-3 4...12 kHz shielded motor cable <20 mproduct certifications NOMULC-TickCSAGOSTvibration resistance 1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-61.5 mm peak to peak (f = 3…13 Hz) - drive unmounted on symmetrical DIN rail - conforming to EN/IEC 60068-2-6shock resistance 15 gn conforming to EN/IEC 60068-2-27 for 11 msrelative humidity 5…95 % without condensation conforming to IEC 60068-2-35…95 % without dripping water conforming to IEC 60068-2-3ambient air temperature for storage -25…70 °Cambient air temperature for operation -10…40 °C protective cover from the top of the drive removed40…60 °C with current derating 2.2 % per °Coperating altitude > 1000...2000 m with current derating 1 % per 100 m<= 1000 m withoutOffer Sustainability Sustainable offer status Green Premium productREACh Regulation EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages30
- English18
- Chinese7
- French8
- German7
- Italian7
- Russian6
- Spanish7
CatalogueFormatSizeAdd to My DocumentsUser guideFormatSizeAdd to My DocumentsATV12 user manual (Version 04)DescriptionSoftware V1.4Size pdfSize 3.6 MBDate 7/2/18DescriptionSoftware V1.41) ATV12 Quick Start annex - SCCR (UL508) (Version 03)DescriptionShort Circuit Current Ratings (SCCR) and branch circuit protection Recommended fuse ratings for UL and CSA requirements. Components for use together in accordance with standard UL508Size pdfSize 162.8 KBDate 4/29/16DescriptionShort Circuit Current Ratings (SCCR) and branch circuit protection Recommended fuse ratings for UL and CSA requirements. Components for use together in accordance with standard UL508ATV12 Modbus Communication Manual (Version 02)DescriptionDownload also (BBV51917) ATV12 Modbus Communication Parameters addresses (Excel file)Size pdfSize 1.7 MBDate 6/29/12DescriptionDownload also (BBV51917) ATV12 Modbus Communication Parameters addresses (Excel file)ATV12 安装及编程手册 - user Manual (Version 04)DescriptionProduct software V1.4Size pdfSize 3.3 MBDate 7/1/18DescriptionProduct software V1.4ATV12 Guide d'exploitation (Version 04)Descriptionlogiciel produit V1.4Size pdfSize 3.3 MBDate 7/1/18Descriptionlogiciel produit V1.4ATV12 Bedienungsanleitung (Version 04)Descriptionproduct software V1.4Size pdfSize 3.3 MBDate 7/1/18Descriptionproduct software V1.4ATV12 Manuale utente (Version 04)Descriptionproduct software V1.4Size pdfSize 4.2 MBDate 7/1/18Descriptionproduct software V1.4ATV12 Manual del usuario (Version 04)Descriptionproduct software V1.4Size pdfSize 3.3 MBDate 7/1/18Descriptionproduct software V1.4CADFormatSizeAdd to My DocumentsCAD for ATV12P037F1: variable speed drive ATV12 - 0.37kW - 0.55hp - 100..120V - 1ph - on base plate (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.CAD for ATV12P037F1: variable speed drive ATV12 - 0.37kW - 0.55hp - 100..120V - 1ph - on base plate (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.CAD file (on TraceParts) for ATV12P037F1: variable speed drive ATV12 - 0.37kW - 0.55hp - 100..120V - 1ph - on base plate (Version 2.0)DescriptionYou will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.CAD file (on TraceParts) for ATV12P037F1: variable speed drive ATV12 - 0.37kW - 0.55hp - 100..120V - 1ph - on base plate (Version 2.0)DescriptionYou will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.CertificateFormatSizeAdd to My DocumentsInstruction sheetFormatSizeAdd to My DocumentsSize pdfSize 711.5 KBDate 3/31/17End of Life InformationFormatSizeAdd to My DocumentsSize pdfSize 178.7 KBDate 3/1/09ALTIVAR 12 - 0.75 kW, 100V, 1 PH -1.5–2.2 kW, 200V, 1PH, Product End-of-Life Instructions (Version 1.0)Size pdfSize 225.5 KBDate 3/1/09EU RoHS DeclarationFormatSizeAdd to My Documentsvariable speed drive ATV12 - 0.37kW - 0.55hp - 100..120V - 1ph - on base plateDescriptionvariable speed drive ATV12 - 0.37kW - 0.55hp - 100..120V - 1ph - on base plateSize pdfSize 195.3 KBDate 12/8/19Descriptionvariable speed drive ATV12 - 0.37kW - 0.55hp - 100..120V - 1ph - on base plateProduct Environmental ProfileFormatSizeAdd to My DocumentsProduct Environmental ProfileAltivar 12Ranges : 0.18-0.37 kW /100V / 1 PH0.18-75 kW / 200V / 1PH or 3PH (Version 1.1)Size pdfSize 961.5 KBDate 2/1/09REACh DeclarationFormatSizeAdd to My Documentsvariable speed drive ATV12 - 0.37kW - 0.55hp - 100..120V - 1ph - on base plateDescriptionvariable speed drive ATV12 - 0.37kW - 0.55hp - 100..120V - 1ph - on base plateSize pdfSize 195.3 KBDate 12/8/19Descriptionvariable speed drive ATV12 - 0.37kW - 0.55hp - 100..120V - 1ph - on base plateChina RoHS declarationFormatSizeAdd to My Documentsvariable speed drive ATV12 - 0.37kW - 0.55hp - 100..120V - 1ph - on base plateDescriptionvariable speed drive ATV12 - 0.37kW - 0.55hp - 100..120V - 1ph - on base plateSize pdfSize 195.3 KBDate 12/8/19Descriptionvariable speed drive ATV12 - 0.37kW - 0.55hp - 100..120V - 1ph - on base plate -
View more
Software and Firmware
Language- All Languages1
- English1
- Chinese1
- French1
- German1
- Italian1
- Spanish1
DTM filesFormatSizeAdd to My DocumentsAltivar DTM Library V12.8: ATV12, ATV31/312, ATV32, ATV61, ATV71, ATV LIFT, ATV212 (Version 12.8)Files in documentDescriptionAltivar DTM Library V12.7.0 = ATV12 (V2.0.1.0) + ATV31/312 (V2.0.2.0) + ATV32 (V2.0.10.0) + ATV61 (V2.0.3.0) + ATV71 (V2.0.3.0) + ATV LIFT(V1.9.2.0) + ATV212 (V2.0.1.0)Size zipSize 422.7 MBDate 5/2/18Files in documentDescriptionAltivar DTM Library V12.7.0 = ATV12 (V2.0.1.0) + ATV31/312 (V2.0.2.0) + ATV32 (V2.0.10.0) + ATV61 (V2.0.3.0) + ATV71 (V2.0.3.0) + ATV LIFT(V1.9.2.0) + ATV212 (V2.0.1.0) -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.