Schneider Electric BMXCRA31210 Image

BMXCRA31210

Green premium brand logo
Schneider Electric BMXCRA31210 Image
BMXCRA31210
Green premium brand logo

Modicon X80 RIO Drop E/IP Performance - Service port - Advanced features

Show more characteristics
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range of product
    Modicon X80
    product or component type
    Ethernet RIO drop adaptor
    Complementary
    bus type
    Bus X across the remote backplane
    number of port
    3
    integrated connection type
    Ethernet/IP for device network
    Ethernet/IP for service port
    communication port protocol
    Ethernet/IP
    communication service
    Output modules are updated with the data received from remote I/O head adaptor
    The input data are collected and published to the remote I/O head adaptor
    Configure IP parameters
    Diagnostics for remote I/O devices
    RSTP support
    function available
    CCOTF (configuration change on the fly)
    data recording
    10 ms time stamps
    topology
    Daisy chain loop
    local signalling
    1 LED (green)module active (RUN):
    1 LED (red)module error (ERR):
    1 LED (green/red)module status (Mod Status):
    1 LED (green/red)network communication status (Net Status):
    1 LED (green)Ethernet link diagnostics (STS):
    product compatibility
    multifunction input module BMXERT
    Ethernet module BMXNOM
    counter module BMXEHC
    0…1024 discrete channel
    0…256 analog channel
    marking
    CE
    module format
    Standard
    maximum altitude transport
    3000 m
    relative humidity
    95 % without condensation
    Environment
    environmental characteristic
    Standard environment
    directives
    2014/35/EU - low voltage directive
    2014/30/EU - electromagnetic compatibility
    2012/19/EU - WEEE directive
    product certifications
    Merchant Navy
    C-Tick
    GOST
    standards
    EN 61131-2
    EN 61000-6-4
    EN 61000-6-2
    EN 61010-2-201
    IP degree of protection
    IP20
    ambient air temperature for operation
    0…60 °C
    ambient air temperature for storage
    -40…85 °C
    operating altitude
    <= 2000 m
    Packing Units
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Weight
    270 g
    Package 1 Height
    5.5 cm
    Package 1 width
    11 cm
    Package 1 Length
    12.5 cm
    Unit Type of Package 2
    S02
    Number of Units in Package 2
    15
    Package 2 Weight
    4.35 kg
    Package 2 Height
    15 cm
    Package 2 width
    30 cm
    Package 2 Length
    40 cm
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages73
    • English32
    • Chinese8
    • French19
    • German8
    • Italian8
    • Spanish8
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 14.5 MB
    Date 12/18/19
    prp.document.label.format pdf
    Size 20 MB
    Date 5/15/18
    prp.document.label.format pdf
    Size 14.3 MB
    Date 2/21/20
    User guide
    Format
    Size
    Date
    Add to My Documents
    Firmware Compatibility Rules - Modicon M580, Modicon Momentum, Modicon MC80, and Modicon X80 I/O Modules (Version 03)
    Description
    This document addresses the firmware compatibility, exceptions, and recommendations for Modicon modules.
    prp.document.label.format pdf
    Size 293.1 KB
    Date 1/1/20
    Description
    This document addresses the firmware compatibility, exceptions, and recommendations for Modicon modules.
    Modicon M580 - RIO Modules, Installation and Configuration Guide (Version 10)
    Description
    This document describes the adapter modules that can be used in X80 RIO drops.This guide describes 3 adapter modules:- BMECRA31210- BMXCRA31210- BMXCRA31200
    prp.document.label.format pdf
    Size 1.7 MB
    Date 10/1/19
    Description
    This document describes the adapter modules that can be used in X80 RIO drops.This guide describes 3 adapter modules:- BMECRA31210- BMXCRA31210- BMXCRA31200
    Modicon M580 - System Planning Guide for Complex Topologies (Version 04)
    Description
    This document presents one of the PlantStruxure features, using Ethernet as the backbone aroundthe Modicon M580 offer to facilitate communications between an M580 local rack and remote subringsthrough dual-ring switches (DRSs).This guide provides detailed information about planning complex M580 architectures, includingthese:- implementation of DRSs to support sub-rings- topology rules and recommendations for choosing a complex network configuration- system performance and limitations- system diagnostics
    prp.document.label.format pdf
    Size 5.4 MB
    Date 10/1/19
    Description
    This document presents one of the PlantStruxure features, using Ethernet as the backbone aroundthe Modicon M580 offer to facilitate communications between an M580 local rack and remote subringsthrough dual-ring switches (DRSs).This guide provides detailed information about planning complex M580 architectures, includingthese:- implementation of DRSs to support sub-rings- topology rules and recommendations for choosing a complex network configuration- system performance and limitations- system diagnostics
    Modicon M580, Hardware Reference Manual (Version 10)
    Description
    This document provides detailed information about the M580 programmable automation controller (PAC), power supplies, and racks. These topics are also discussed:- Install a local rack in the M580 system.- Configure the M580 CPU.- The CPU performs Ethernet I/O scanning of both RIO and DIO logic without affecting network determinism.
    prp.document.label.format pdf
    Size 12.3 MB
    Date 10/1/19
    Description
    This document provides detailed information about the M580 programmable automation controller (PAC), power supplies, and racks. These topics are also discussed:- Install a local rack in the M580 system.- Configure the M580 CPU.- The CPU performs Ethernet I/O scanning of both RIO and DIO logic without affecting network determinism.
    Modicon M580 Standalone System Planning Guide for Frequently Used Architectures (Version 10)
    Description
    This document presents one of the PlantStruxure features, using Ethernet as the backbone around the Modicon M580 offer and connecting an M580 local rack and M580 RIO drops.This guide provides detailed information about planning frequently used M580 architectures, including the following:- Ethernet I/O networks (RIO and distributed equipment integrated on the same physical network)- topology rules and recommendations for choosing a network configuration- role of network option switch modules- system commissioning and maintenance- system performance and limitations- system diagnostics
    prp.document.label.format pdf
    Size 18.2 MB
    Date 10/1/19
    Description
    This document presents one of the PlantStruxure features, using Ethernet as the backbone around the Modicon M580 offer and connecting an M580 local rack and M580 RIO drops.This guide provides detailed information about planning frequently used M580 architectures, including the following:- Ethernet I/O networks (RIO and distributed equipment integrated on the same physical network)- topology rules and recommendations for choosing a network configuration- role of network option switch modules- system commissioning and maintenance- system performance and limitations- system diagnostics
    Quantum EIO - Remote I/O Modules, Installation and Configuration Guide (Version 12)
    Description
    This guide describes these modules and their roles in a Quantum EIO system:- 140 CRP 312 00: remote I/O head module on a Quantum local rack in a remote I/O main ring- 140 CRA 312 00: remote I/O adapter module in a Quantum remote I/O drop- BMX CRA 312 .0: remote I/O adapter module in a Modicon X80Modicon X80 remote I/O drop
    prp.document.label.format pdf
    Size 3.2 MB
    Date 10/1/19
    Description
    This guide describes these modules and their roles in a Quantum EIO system:- 140 CRP 312 00: remote I/O head module on a Quantum local rack in a remote I/O main ring- 140 CRA 312 00: remote I/O adapter module in a Quantum remote I/O drop- BMX CRA 312 .0: remote I/O adapter module in a Modicon X80Modicon X80 remote I/O drop
    Modicon X80 - Racks and Power Supplies, Hardware Reference Manual (Version 04)
    Description
    This document provides detailed information about the Modicon X80 racks and power supplies used for M340 station, M580 system, and X80 drops.
    prp.document.label.format pdf
    Size 3 MB
    Date 10/1/19
    Description
    This document provides detailed information about the Modicon X80 racks and power supplies used for M340 station, M580 system, and X80 drops.
    Modicon M580, Safety Manual (Version 05)
    Description
    This Safety Manual describes the modules of the M580 safety system with special regard as to how they meet the Safety requirements of the IEC 61508 standard. It provides detailed information on how to install, run, and maintain the system correctly in order to protect human beings as well as to prevent damage to environment, equipment, and production.
    prp.document.label.format pdf
    Size 12 MB
    Date 9/1/19
    Description
    This Safety Manual describes the modules of the M580 safety system with special regard as to how they meet the Safety requirements of the IEC 61508 standard. It provides detailed information on how to install, run, and maintain the system correctly in order to protect human beings as well as to prevent damage to environment, equipment, and production.
    Modicon M580, Safety System Planning Guide (Version 05)
    Description
    This Safety System Planning Guide describes the modules of the M580 Safety system with special regard to how they meet the Safety requirements of the IEC 61508. It provides detailed information on how to install, run, and maintain the system correctly in order to help protect human beings as well as to help prevent damage to environment, equipment, and production.
    prp.document.label.format pdf
    Size 7.9 MB
    Date 9/1/19
    Description
    This Safety System Planning Guide describes the modules of the M580 Safety system with special regard to how they meet the Safety requirements of the IEC 61508. It provides detailed information on how to install, run, and maintain the system correctly in order to help protect human beings as well as to help prevent damage to environment, equipment, and production.
    EcoStruxure™ Control Expert - Applicative Time Stamping, User Guide (Version 04)
    Description
    This document presents a PlantStruxure feature: at source applicative time stamping. This guide presents detailed information about applicative time stamping, including the following: - Applicative time stamping architecture - Design and configuration phases - Commissioning and operation phases
    prp.document.label.format pdf
    Size 3.5 MB
    Date 12/1/18
    Description
    This document presents a PlantStruxure feature: at source applicative time stamping. This guide presents detailed information about applicative time stamping, including the following: - Applicative time stamping architecture - Design and configuration phases - Commissioning and operation phases
    prp.document.label.format pdf
    Size 2.6 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 5.5 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 16.4 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 3.6 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 9.1 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 3.3 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 7.1 MB
    Date 9/1/19
    prp.document.label.format pdf
    Size 3.6 MB
    Date 7/1/18
    prp.document.label.format pdf
    Size 10.4 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 1.1 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 5.6 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 16.2 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 3.6 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 3.3 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 6.6 MB
    Date 9/1/19
    prp.document.label.format pdf
    Size 3.6 MB
    Date 7/1/18
    prp.document.label.format pdf
    Size 3.3 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 2.7 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 10.1 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 16.8 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 5.6 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 3.5 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 6.5 MB
    Date 9/1/19