Welcome to the Schneider Electric corporate Website

Select your location

Welcome the the Schneider Electric French website. It looks like you are located in the United States, would you like to change your location?

Traduisez en francais
View all   Modicon M340
Schneider Electric BMXP341000 Image

BMXP341000

Green premium brand logo
Schneider Electric BMXP341000 Image
BMXP341000
Green premium brand logo

processor module M340 - max 512 discrete + 128 analog I/O - Modbus

Show more characteristics
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range of product
    Modicon M340 automation platform
    product or component type
    Processor module
    number of racks
    2
    number of slots
    11
    discrete I/O processor capacity
    512 I/O single-rack configuration
    analogue I/O processor capacity
    66 I/O single-rack configuration
    128 I/O multi-rack configuration
    number of application specific channel
    20
    monitoring
    Diagnostic counters Modbus
    Event counters Modbus
    Complementary
    control channels
    Programmable loops
    integrated connection type
    Non isolated serial link RJ45 character mode, transmission mode: asynchronous in baseband, RS232C, transmission mode: 2 twisted shielded pairs at 0.3...19.2 kbit/s full duplex
    Non isolated serial link RJ45 character mode, transmission mode: asynchronous in baseband, RS485, transmission mode: 1 twisted shielded pair at 0.3...19.2 kbit/s half duplex
    Non isolated serial link RJ45, master/slave Modbus, RTU/ASCII, transmission mode: asynchronous in baseband, RS232C, transmission mode: 1 twisted shielded pair at 0.3...19.2 kbit/s half duplex
    Non isolated serial link RJ45, master/slave Modbus, RTU/ASCII, transmission mode: asynchronous in baseband, RS485, transmission mode: 1 twisted shielded pair at 0.3...19.2 kbit/s half duplex
    USB port at 12 Mbit/s
    communication module processor capacity
    2 Ethernet communication module
    2 AS-Interface module
    number of devices per segment
    0…32 (character mode)
    0…32 (Modbus)
    number of devices
    2 point-to-point character mode
    2 point-to-point Modbus
    bus length
    0…10 m serial link non isolated character mode segment
    0…10 m serial link non isolated Modbus segment
    0…1000 m serial link isolated character mode segment
    0…1000 m serial link isolated Modbus segment
    0…15 m character mode point-to-point
    0…15 m Modbus point-to-point
    maximum tap links length
    <15 m serial link non isolated character mode segment
    <15 m serial link non isolated Modbus segment
    <40 m serial link isolated character mode segment
    <40 m serial link isolated Modbus segment
    number of addresses
    0…248 for character mode
    0…248 for Modbus
    requests
    1 K data bytes per request character mode
    252 data bytes per RTU request Modbus
    504 data bytes per ASCII request Modbus
    control parameter
    One CRC on each frame (RTU) Modbus
    One LRC on each frame (ASCII) character mode
    One LRC on each frame (ASCII) Modbus
    memory description
    Internal RAM 2048 kB
    Internal RAM 128 kB data
    Internal RAM 1792 kB program constants and symbols
    Supplied memory card (BMXRMS008MP) backup of programs, constants, symbols and data
    maximum size of object areas
    128 kB unlocated internal data
    16250 %Mi located internal bits
    32464 %MWi internal words located internal data
    32760 %KWi constant words located internal data
    default size of object areas
    128 %KWi constant words located internal data
    256 %Mi located internal bits
    512 %MWi internal words located internal data
    application structure
    1 periodic fast task
    32 event tasks
    1 cyclic/periodic master task
    No auxiliary task
    execution time per instruction
    0.18 µs Boolean
    0.26 µs double-length words
    0.38 µs single-length words
    1.74 µs floating points
    number of instructions per ms
    4.2 Kinst/ms 65 % Boolean + 35 % fixed arithmetic
    5.4 Kinst/ms 100 % Boolean
    system overhead
    0.2 ms for fast task
    1.05 ms for master task
    current consumption
    72 mA at 24 V DC
    supply
    Internal power supply via rack
    marking
    CE
    status LED
    1 LED (green)processor running (RUN):
    1 LED (red)I/O module fault (I/O):
    1 LED (red)memory card fault (CARD ERR):
    1 LED (red)processor or system fault (ERR):
    1 LED (yellow)activity on Modbus (SER COM):
    net weight
    0.2 kg
    Environment
    ambient air temperature for operation
    0…60 °C
    relative humidity
    10…95 % without condensation
    IP degree of protection
    IP20
    protective treatment
    TC
    directives
    2014/35/EU - low voltage directive
    2014/30/EU - electromagnetic compatibility
    2012/19/EU - WEEE directive
    standards
    EN 61131-2
    EN 61000-6-4
    EN 61000-6-2
    EN 61010-2-201
    Packing Units
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Weight
    237 g
    Package 1 Height
    5.5 cm
    Package 1 width
    11 cm
    Package 1 Length
    11.5 cm
    Unit Type of Package 2
    S02
    Number of Units in Package 2
    15
    Package 2 Weight
    3.981 kg
    Package 2 Height
    15 cm
    Package 2 width
    30 cm
    Package 2 Length
    40 cm
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages76
    • English35
    • Chinese11
    • French22
    • German11
    • Italian11
    • Spanish11
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 8 MB
    Date 10/29/14
    prp.document.label.format pdf
    Size 8.7 MB
    Date 10/29/14
    User guide
    Format
    Size
    Date
    Add to My Documents
    Firmware Compatibility Rules - Modicon M580, Modicon Momentum, Modicon MC80, and Modicon X80 I/O Modules (Version 03)
    Description
    This document addresses the firmware compatibility, exceptions, and recommendations for Modicon modules.
    prp.document.label.format pdf
    Size 293.1 KB
    Date 1/1/20
    Description
    This document addresses the firmware compatibility, exceptions, and recommendations for Modicon modules.
    Modicon M580 - RIO Modules, Installation and Configuration Guide (Version 10)
    Description
    This document describes the adapter modules that can be used in X80 RIO drops.This guide describes 3 adapter modules:- BMECRA31210- BMXCRA31210- BMXCRA31200
    prp.document.label.format pdf
    Size 1.7 MB
    Date 10/1/19
    Description
    This document describes the adapter modules that can be used in X80 RIO drops.This guide describes 3 adapter modules:- BMECRA31210- BMXCRA31210- BMXCRA31200
    Modicon M580, Hardware Reference Manual (Version 10)
    Description
    This document provides detailed information about the M580 programmable automation controller (PAC), power supplies, and racks. These topics are also discussed:- Install a local rack in the M580 system.- Configure the M580 CPU.- The CPU performs Ethernet I/O scanning of both RIO and DIO logic without affecting network determinism.
    prp.document.label.format pdf
    Size 12.3 MB
    Date 10/1/19
    Description
    This document provides detailed information about the M580 programmable automation controller (PAC), power supplies, and racks. These topics are also discussed:- Install a local rack in the M580 system.- Configure the M580 CPU.- The CPU performs Ethernet I/O scanning of both RIO and DIO logic without affecting network determinism.
    Modicon M580 Standalone System Planning Guide for Frequently Used Architectures (Version 10)
    Description
    This document presents one of the PlantStruxure features, using Ethernet as the backbone around the Modicon M580 offer and connecting an M580 local rack and M580 RIO drops.This guide provides detailed information about planning frequently used M580 architectures, including the following:- Ethernet I/O networks (RIO and distributed equipment integrated on the same physical network)- topology rules and recommendations for choosing a network configuration- role of network option switch modules- system commissioning and maintenance- system performance and limitations- system diagnostics
    prp.document.label.format pdf
    Size 18.2 MB
    Date 10/1/19
    Description
    This document presents one of the PlantStruxure features, using Ethernet as the backbone around the Modicon M580 offer and connecting an M580 local rack and M580 RIO drops.This guide provides detailed information about planning frequently used M580 architectures, including the following:- Ethernet I/O networks (RIO and distributed equipment integrated on the same physical network)- topology rules and recommendations for choosing a network configuration- role of network option switch modules- system commissioning and maintenance- system performance and limitations- system diagnostics
    Modicon M340 - Processors, Setup Manual (Version 14)
    Description
    This manual describes the hardware installation of PLCs in the Modicon M340 range as well as the installation of their main accessories. This document is also valid for the Modicon M340H PLCs and their accessories.
    prp.document.label.format pdf
    Size 1.1 MB
    Date 10/1/19
    Description
    This manual describes the hardware installation of PLCs in the Modicon M340 range as well as the installation of their main accessories. This document is also valid for the Modicon M340H PLCs and their accessories.
    Modicon X80 - Racks and Power Supplies, Hardware Reference Manual (Version 04)
    Description
    This document provides detailed information about the Modicon X80 racks and power supplies used for M340 station, M580 system, and X80 drops.
    prp.document.label.format pdf
    Size 3 MB
    Date 10/1/19
    Description
    This document provides detailed information about the Modicon X80 racks and power supplies used for M340 station, M580 system, and X80 drops.
    Unity Loader, User Manual (Version 12)
    Description
    This document describes the Unity Loader stand-alone tool. Unity Loader can transfer Control Expert, Unity Pro applications bidirectionally between a PC and a Modicon M340, M580, Momentum, Premium or Quantum PLC.
    prp.document.label.format pdf
    Size 773.3 KB
    Date 12/1/18
    Description
    This document describes the Unity Loader stand-alone tool. Unity Loader can transfer Control Expert, Unity Pro applications bidirectionally between a PC and a Modicon M340, M580, Momentum, Premium or Quantum PLC.
    Modicon M340 - Serial Link, User Manual (Version 14)
    Description
    This manual describes the principle for hardware and software implementation of character mode and Modbus communication for Modicon M340 PLCs.
    prp.document.label.format pdf
    Size 2.1 MB
    Date 12/1/18
    Description
    This manual describes the principle for hardware and software implementation of character mode and Modbus communication for Modicon M340 PLCs.
    M340 - Communication Services and Architectures, Unity Pro S (Version 05)
    Description
    This manual presents the architectures and communication services associated with Schneider PLCs programmed using Unity Pro S.
    prp.document.label.format pdf
    Size 862.3 KB
    Date 7/1/11
    Description
    This manual presents the architectures and communication services associated with Schneider PLCs programmed using Unity Pro S.
    prp.document.label.format pdf
    Size 9.1 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 3.3 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 2.6 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 16.4 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 1 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 2.3 MB
    Date 12/1/18
    prp.document.label.format pdf
    Size 1,018.7 KB
    Date 12/1/18
    prp.document.label.format pdf
    Size 962.7 KB
    Date 7/1/11
    prp.document.label.format pdf
    Size 16.2 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 947.5 KB
    Date 10/1/19
    prp.document.label.format pdf
    Size 3.3 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 1.1 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 10.4 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 1.4 MB
    Date 12/1/18
    prp.document.label.format pdf
    Size 2.2 MB
    Date 12/1/18
    prp.document.label.format pdf
    Size 1 MB
    Date 7/1/11
    prp.document.label.format pdf
    Size 16.8 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 10.1 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 2.7 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 953.5 KB
    Date 10/1/19
    prp.document.label.format pdf
    Size 3.3 MB
    Date 10/1/19
    prp.document.label.format pdf
    Size 2.3 MB
    Date 12/1/18