View all
TeSys Control Relays

CA2KN223G7
CA2KN223G7
TeSys K control relay - 2 NO + 2 NC - <= 690 V - 120 V AC coil
Show more characteristics
has not been replaced. Please contact your customer care center for more information.
-
Characteristics
Main range TeSysproduct name TeSys CAKproduct or component type Control relaydevice short name CA2Kcontactor application Control circuitutilisation category DC-13AC-15pole contact composition 2 NO + 2 NC[Ue] rated operational voltage <= 690 V <= 400 Hzcontrol circuit type AC at 50/60 Hz[Uc] control circuit voltage 120 V AC 50/60 HzComplementary [Ith] conventional free air thermal current 10 A (at 50 °C)Irms rated making capacity 110 A conforming to IEC 60947associated fuse rating 10 A gG conforming to IEC 6094710 A gG conforming to VDE 0660[Ui] rated insulation voltage 690 V conforming to IEC 60947750 V conforming to VDE 0110 group C690 V conforming to BS 5424600 V conforming to CSA C22.2 No 14mounting support PlateRailconnections - terminals Spring terminals 1 cable(s) 0.75…1.5 mm²solidSpring terminals 1 cable(s) 0.75…1.5 mm²flexible without cable endcontrol circuit voltage limits Drop-out: 0.2...0.75 Uc (at <50 °C)Operational: 0.8...1.15 Uc (at <50 °C)operating time 10...20 ms coil de-energisation and NO opening10...20 ms coil energisation and NO closing15...25 ms coil de-energisation and NC closing5...15 ms coil energisation and NC openingmechanical durability 10 Mcyclesmaximum operating rate 10000 cyc/himmunity to microbreaks 2 msinrush power in VA 30 VA (at 20 °C)hold-in power consumption in VA 4.5 VA (at 20 °C)heat dissipation 1.3 Wminimum switching voltage 17 Vminimum switching current 5 mAnon overlap distance 0.5 mminsulation resistance > 10 MOhmheight 58 mmwidth 45 mmdepth 57 mmnet weight 0.18 kgEnvironment standards BS 5424IEC 60947NF C 63-140VDE 0660product certifications CSAULprotective treatment TC conforming to IEC 60068ambient air temperature for operation -25…50 °Cambient air temperature for storage -50…80 °Coperating altitude 2000 m withoutflame retardance V1 conforming to UL 94Requirement 2 conforming to NF F 16-101Requirement 2 conforming to NF F 16-102mechanical robustness Vibrations contactor open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6Shocks contactor open: 10 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor closed: 15 Gn for 11 ms conforming to IEC 60068-2-27Contractual warranty Warranty 18 months -
View more
Documents
Language- All Languages6
- English4
- French3
CatalogueFormatSizeAdd to My DocumentsTesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.Size pdfSize 111.5 MBDate 7/12/19DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.TeSys catalogue - 2019 - 2020 - chapter B7 Control relays- TeSys SK, K, D (Version 6.0)DescriptionRelays for control of contactor coils or other devices - 2 to 5 contacts - accessories - TeSys SK, K and D familiesSize pdfSize 3.1 MBDate 5/15/19DescriptionRelays for control of contactor coils or other devices - 2 to 5 contacts - accessories - TeSys SK, K and D familiesCatalogue TeSys 2019 - Composants pour protection et commande de moteurs (Version 7.1)DescriptionLe catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.Size pdfSize 108.2 MBDate 7/12/19DescriptionLe catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.Catalogue TeSys 2019 - Chapitre B7 - Contacteurs auxiliaires (Version 4.0)DescriptionPrésentation des contacteurs auxiliaires, relais, des gammes TeSys SK, SKE, K, DSize pdfSize 3.3 MBDate 6/11/19DescriptionPrésentation des contacteurs auxiliaires, relais, des gammes TeSys SK, SKE, K, DCADFormatSizeAdd to My DocumentsCAD for CA2KN223G7: TeSys K control relay - 2 NO + 2 NC - <= 690 V - 120 V AC coil (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.CAD for CA2KN223G7: TeSys K control relay - 2 NO + 2 NC - <= 690 V - 120 V AC coil (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.Product Environmental ProfileFormatSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.