Welcome to the Schneider Electric corporate Website

Select your location

View all   Enerlin'X Com'X
Schneider Electric EBX210 Image

EBX210

Schneider Electric EBX210 Image
EBX210

ComX 210 - data logger - UL

Show more characteristics
The maximum number of products that can be compared is 4

  • Main
    range
    PowerLogic
    product name
    ComX
    product or component type
    Energy server
    device short name
    ComX 210
    Complementary
    [Us] rated supply voltage
    Main supply: 24 V DC
    maximum power consumption in W
    26 W 24 V
    15 W via PoE
    communication network type
    RS485, Modbus serial on 1 RJ45
    RS485, Modbus serial on terminal block
    Ethernet, PoE 15W (Power over Ethernet) on 1 RJ45
    Ethernet, DHCP on 1 RJ45
    number of inputs
    6 digital
    2 analog
    discrete input current
    60 mA at 12 V DC
    sensor power supply
    24 V DC at 50 mA
    analogue input type
    4...20 mA
    Pt 100
    Pt 1000
    0...10 V
    communication gateway
    Ethernet TCP/IP to Modbus
    memory capacity
    128 MB RAM
    256 MB flash
    mounting mode
    Clip-on
    mounting support
    35 mm DIN rail
    product certifications
    CE
    CUL
    C-Tick
    UL
    standards
    EN 61010-1
    UL 508
    EN 60950
    UL 60950
    depth
    69 mm
    height
    109 mm
    width
    144 mm
    net weight
    450 g
    local signalling
    LED: for power supply
    LED: for status (GPRS)
    LED: for communication (Modbus)
    LED: for communication (Ethernet)
    LED: for communication (WiFi)
    LED: for I/O
    Environment
    relative humidity
    5…95 % at 55 °C without condensation
    IP degree of protection
    IP20 (terminal block)
    IP40 (front face)
    ambient air temperature for operation
    -25…70 °C
    ambient air temperature for storage
    -40…85 °C
    pollution degree
    3
    operating altitude
    2000 m
    Offer Sustainability
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
  • View more View less

    Documents

    Language
    • All Languages23
    • English14
    • Chinese4
    • Dutch3
    • French5
    • German4
    • Italian3
    • Japanese2
    • Portuguese4
    • Russian4
    • Spanish3
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    PowerLogic Catalog - 247 pages Web (NO PRINTED VERSION AVAILABLE) (Version 8.5)
    Description
    Note that no printed catalogs are available but all necessary source files, in 13 sections, are available for download from the Shopping Kiosk.
    prp.document.label.format pdf
    Size 12.3 MB
    Date 1/25/20
    Description
    Note that no printed catalogs are available but all necessary source files, in 13 sections, are available for download from the Shopping Kiosk.
    prp.document.label.format pdf
    Size 15.9 MB
    Date 12/18/19
    User guide
    Format
    Size
    Date
    Add to My Documents
    Com’X 210/510 Hardening Guide (Version 1.0)
    Description
    This guide provides recommendations to better secure your Com’X device.Please use this guide in conjunction with the user manual for the step by step procedure details required for the configuration of specific features and settings.NOTE: This guide is applicable for Com'X firmware version 6.5 and above.
    prp.document.label.format pdf
    Size 1 MB
    Date 12/4/19
    Description
    This guide provides recommendations to better secure your Com’X device.Please use this guide in conjunction with the user manual for the step by step procedure details required for the configuration of specific features and settings.NOTE: This guide is applicable for Com'X firmware version 6.5 and above.
    Com’X 210/510 Security Certificate Installation Guide (Version 1.0)
    Description
    It is recommended to procure and install your own Public/Private SSL Certificate to harden your Com’X device. This guide details a multi-step process. The first part of the process involves creating a Com’X compliant certificate file from your SSL certificate & private key. The second part of the process instructs on how to install the certificate on a Com’X.NOTE: This guide is applicable for Com'X firmware version 6.5 and above.
    prp.document.label.format pdf
    Size 587.2 KB
    Date 12/4/19
    Description
    It is recommended to procure and install your own Public/Private SSL Certificate to harden your Com’X device. This guide details a multi-step process. The first part of the process involves creating a Com’X compliant certificate file from your SSL certificate & private key. The second part of the process instructs on how to install the certificate on a Com’X.NOTE: This guide is applicable for Com'X firmware version 6.5 and above.
    Com’X 210 Energy Server User manual (Version 13)
    Description
    Com’X 210 Energy Server User manual
    prp.document.label.format pdf
    Size 3.4 MB
    Date 12/1/19
    Description
    Com’X 210 Energy Server User manual
    Com'X 200/210/510 Commissioning Quick Start Guide (Version 01)
    Description
    This guide provides an overview of the commissioning process for a new Com'X 510. These guidelines can help reduce commissioning time by eliminating unnecessary reboots and adding device configuration at the optimal time.
    prp.document.label.format pdf
    Size 421.9 KB
    Date 1/1/17
    Description
    This guide provides an overview of the commissioning process for a new Com'X 510. These guidelines can help reduce commissioning time by eliminating unnecessary reboots and adding device configuration at the optimal time.
    Com'X 210 电能服务器 用户指南 (Version 12)
    Description
    Com'X 210 电能服务器 用户指南
    prp.document.label.format pdf
    Size 3.5 MB
    Date 12/1/19
    Description
    Com'X 210 电能服务器 用户指南
    Serveur d’énergie Com’X 210 Manuel de l’utilisateur (Version 12)
    Description
    Serveur d’énergie Com’X 210 Manuel de l’utilisateur
    prp.document.label.format pdf
    Size 3.5 MB
    Date 12/1/19
    Description
    Serveur d’énergie Com’X 210 Manuel de l’utilisateur
    Com’X 210-Energieserver Benutzerhandbuch (Version 12)
    Description
    Com’X 210-Energieserver Benutzerhandbuch
    prp.document.label.format pdf
    Size 3.5 MB
    Date 12/1/19
    Description
    Com’X 210-Energieserver Benutzerhandbuch
    Server di energia Com'X 210 Manuale utente (Version 12)
    Description
    Server di energia Com'X 210 Manuale utente
    prp.document.label.format pdf
    Size 3.5 MB
    Date 12/1/19
    Description
    Server di energia Com'X 210 Manuale utente
    prp.document.label.format pdf
    Size 3.4 MB
    Date 4/30/19
    Энергетический сервер Com'X 210 Руководство пользователя (Version 12)
    Description
    Энергетический сервер Com'X 210 Руководство пользователя
    prp.document.label.format pdf
    Size 3.6 MB
    Date 12/1/19
    Description
    Энергетический сервер Com'X 210 Руководство пользователя
    prp.document.label.format pdf
    Size 3.2 MB
    Date 12/18/19
    CAD
    Format
    Size
    Date
    Add to My Documents
    CAD file (on TraceParts) for EBX210: ComX 210 - data logger - UL (Version 2.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    CAD file (on TraceParts) for EBX210: ComX 210 - data logger - UL (Version 2.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 4.8 MB
    Date 2/1/17
    EBXA-USB-WIFI Additional Information (Version 00)
    Description
    EBXA-USB-WIFI Additional Information, 253537634-00
    prp.document.label.format pdf
    Size 1.8 MB
    Date 7/1/15
    Description
    EBXA-USB-WIFI Additional Information, 253537634-00
    prp.document.label.format pdf
    Size 22.2 MB
    Date 2/1/17
    prp.document.label.format pdf
    Size 21.9 MB
    Date 2/1/17
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    EBX210 : ComX 210 - data logger - UL
    Description
    ComX 210 - data logger - UL
    prp.document.label.format pdf
    Size 195.3 KB
    Date 2/20/20
    Description
    ComX 210 - data logger - UL
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    ECDCom'x&accessories-V1 (Version 1.0)
    Description
    EU Declaration of Conformity for Com'X and accessories
    prp.document.label.format pdf
    Size 646.2 KB
    Date 5/6/16
    Description
    EU Declaration of Conformity for Com'X and accessories
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    EBX210 : ComX 210 - data logger - UL
    Description
    ComX 210 - data logger - UL
    prp.document.label.format pdf
    Size 195.3 KB
    Date 2/20/20
    Description
    ComX 210 - data logger - UL
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    EBX210 : ComX 210 - data logger - UL
    Description
    ComX 210 - data logger - UL
    prp.document.label.format pdf
    Size 195.3 KB
    Date 2/20/20
    Description
    ComX 210 - data logger - UL
    Technical leaflet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 466.7 KB
    Date 4/2/18
  • View more View less

    Software and Firmware

    Language
    • English2
    Firmware - Released
    Format
    Size
    Date
    Add to My Documents
    Com'X 210 v6.5.4 (Version 6.5.4)
    Description
    If your Com’X 210 device is currently running a firmware version earlier than v2.1, you must first upgrade to v2.1 before upgrading to later versions.
    prp.document.label.format zip
    Size 47.8 MB
    Date 12/15/19
    Description
    If your Com’X 210 device is currently running a firmware version earlier than v2.1, you must first upgrade to v2.1 before upgrading to later versions.
    ComX210v2-1-18_Firmware_EBX210 (Version 2.1.18)
    Description
    Com’X firmware upgrade to address bug fixes.Updates:Com’X 200/210Known Issues:1. After upgrading to V2.1.18 from a previous version, the Com’X occasionally fails to communicate toconfigured Zigbee devices on its first startup. To correct this, cycle the power to the Com’X orpress “Restart” on the Maintenance > System Settings page. This is not a reoccurring issue.2. After upgrading to V2.1.18 from a previous version, measurements selected for publication arecleared. To continue to publish, the measurement selections must be reselected.Corrections:1. Corrected issue where after an upgrade to V2.1.17, the Local IDs defaulted to 1, causing loss ofcommunications to devices.2. Corrected issue where after an upgrade to V2.1.17, changing Local IDs in the Settings > ModbusGateway > Device IDs page caused the device to be removed or communications lost.Com’X 510Corrections:1. Corrected the issue of excessive time to load the Measurement Table for the CM4000 and CM3000variants, which also reduced the gateway bandwidth.2. Corrected issue where the data series in the 4 Weeks over 4 Weeks energy dashboard reportsinaccurate Date/Time values when the time zone is configured with a positive offset.3. Updated the on-board User Manual to the correct 2.1 version.
    prp.document.label.format zip
    Size 40 MB
    Date 1/29/16
    Description
    Com’X firmware upgrade to address bug fixes.Updates:Com’X 200/210Known Issues:1. After upgrading to V2.1.18 from a previous version, the Com’X occasionally fails to communicate toconfigured Zigbee devices on its first startup. To correct this, cycle the power to the Com’X orpress “Restart” on the Maintenance > System Settings page. This is not a reoccurring issue.2. After upgrading to V2.1.18 from a previous version, measurements selected for publication arecleared. To continue to publish, the measurement selections must be reselected.Corrections:1. Corrected issue where after an upgrade to V2.1.17, the Local IDs defaulted to 1, causing loss ofcommunications to devices.2. Corrected issue where after an upgrade to V2.1.17, changing Local IDs in the Settings > ModbusGateway > Device IDs page caused the device to be removed or communications lost.Com’X 510Corrections:1. Corrected the issue of excessive time to load the Measurement Table for the CM4000 and CM3000variants, which also reduced the gateway bandwidth.2. Corrected issue where the data series in the 4 Weeks over 4 Weeks energy dashboard reportsinaccurate Date/Time values when the time zone is configured with a positive offset.3. Updated the on-board User Manual to the correct 2.1 version.
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.