Welcome to the Schneider Electric corporate Website

Select your location

Welcome the the Schneider Electric French website. It looks like you are located in the United States, would you like to change your location?

Traduisez en francais
View all   SM6-24
Schneider Electric F-SM6R-QM-A2 Image
Discontinued

F-SM6R-QM-A2

Schneider Electric F-SM6R-QM-A2 Image
Discontinued
F-SM6R-QM-A2

SM6-24 QM500 LBS Mot630A,CI2,motorised220Vac,T. Fuse,Fuse HolderDIN cubicle

Show more characteristics
F-SM6R-QM-A2 has not been replaced. Please contact your customer care center for more information.
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range of product
    SM6
    technology type
    Air insulated switchgear
    device short name
    QM 500
    product or component type
    Fuse-switch
    internal arc protection
    12.5 kA 1 s
    Rated voltage (Ur)
    24 kV
    Rated normal current (Ir)
    630 A
    Complementary
    cable connection
    1 x 95 mm² per phase (bottom)
    bus rated current
    630 A
    type of operator
    CI2 motor mechanism
    control circuit voltage (Uc)
    220 V AC opening coil
    220 V AC motor
    fuse type
    FUSARC 6.3…125 A
    number of contacts
    2
    contacts type and composition
    1 NO + 1 NC
    counting device type
    Operating counter optional
    width
    500 mm
    depth
    950 mm
    net weight
    130 kg
    Environment
    standards
    IEC 62271-200
    ambient air temperature for operation
    -5…40 °C
    IP degree of protection
    IP3x
    vibration resistance
    0.5 gn horizontal class 2
    0.4 gn vertical class 2
    operating altitude
    <= 1000 m
  • View more View less

    Documents

    Language
    • All Languages7
    • English7
    • French1
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 13.2 MB
    Date 5/15/20
    Description
    2015 edition
    User guide
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 15.7 MB
    Date 3/12/20
    Installation and Commissioning Guide (Version 01)
    Description
    Installation and Commissioning Guide for all functions and accessories for SM6-24kV range
    prp.document.label.format pdf
    Size 15.7 MB
    Date 9/26/19
    Description
    Installation and Commissioning Guide for all functions and accessories for SM6-24kV range
    CAD
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format dxf
    Size 551.1 KB
    Date 5/9/17
    prp.document.label.format stp
    Size 758.2 KB
    Date 5/9/17
    Certificate
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 254.7 KB
    Date 9/11/19
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 158 KB
    Date 5/22/19
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.