Welcome to the Schneider Electric corporate Website

Select your location

View all   Galaxy 300
Schneider Electric G3HT20K3IB1S Image

G3HT20K3IB1S

Schneider Electric G3HT20K3IB1S Image
G3HT20K3IB1S

MGE Galaxy 300 20kVA 400V 3:1 with 10min Battery, Start-up 5x8

Show more characteristics
The maximum number of products that can be compared is 4

  • Overview
    Description
    Effective three phase power protection against downtime and data loss for mission critical applications. Ruggedized version including dust filter and conformance coated boards for harsh environments.
    Model Name
    MGE Galaxy 300 20kVA 400V 3:1 with 10min Battery, Start-up 5x8
    Includes
    CD with software , Installation guide , Network Management Card , Start-Up Service , User Manual
    Standard Lead Time
    Usually Ships within 2 Weeks
    Product Distribution
    Afghanistan , Albania , Algeria , Andorra , Angola , Argentina , Armenia , Australia , Austria , Azerbaijan , Bahrain , Belarus , Belgium , Benin , Bhutan , Bolivia , Bosnia And Herzegovina , Botswana , Brunei Darussalam , Bulgaria , Burkina Faso , Burundi , Cambodia , Cameroon , Central African Republic , Chad , Chile , China , Congo , CONGO, THE DEMOCRATIC REPUBLIC OF THE , Cook Islands , Cote D'Ivoire , Croatia , Cyprus , Czech Republic , Denmark , Djibouti , East Timor , Egypt , Equatorial Guinea , Eritrea , Estonia , Ethiopia , Fiji , Finland , France , Gabon , Gambia , Georgia , Germany , Ghana , Gibraltar , Greece , Guadeloupe , Guinea , French Guiana , Hong Kong , Hungary , Iceland , Indonesia , Iran (Islamic Republic Of) , Iraq , Ireland , Israel , Italy , Jamaica , Jordan , Kazakhstan , Kenya , Kuwait , Latvia , Lebanon , Lesotho , Liberia , Liechtenstein , Lithuania , Luxembourg , Macedonia , Madagascar , Malawi , Malaysia , Mali , Malta , Martinique , Mauritania , Mauritius , Mayotte , Moldova, Republic Of , Mongolia , Morocco , Mozambique , Myanmar , Namibia , Nepal , Netherlands , New Zealand , Niger , Nigeria , Norway , Oman , Pakistan , Papua New Guinea , Paraguay , Peru , Philippines , Poland , Portugal , Reunion , Romania , Russian Federation , Rwanda , Saudi Arabia , Senegal , Sierra Leone , Singapore , Slovakia (Slovak Republic) , Slovenia , Somalia , South Africa , Spain , Sudan , Suriname , Sweden , Taiwan , Tajikistan , TANZANIA, UNITED REPUBLIC OF , Thailand , Togo , Tunisia , Turkey , Turkmenistan , Turks And Caicos Islands , Uganda , Ukraine , United Arab Emirates , Uruguay , Uzbekistan , Viet Nam , Western Sahara , Yemen , Zambia , Zimbabwe
    Output
    Output Power Capacity
    16.0 KW / 20.0 kVA
    Max Configurable Power (Watts)
    16.0 KW / 20.0 kVA
    Nominal Output Voltage
    230V
    Output Voltage Note
    Configurable for 220 : 230 or 240 nominal output voltage
    Output Voltage Distortion
    Less than 5%
    Output Frequency (sync to mains)
    50/60 Hz +/- 5%
    Other Output Voltages
    220, 240V
    Crest Factor
    2.5 : 1
    Double Conversion Online
    Waveform Type
    Sine wave
    Output Connections
    (1) Hard Wire 3-wire (H N + G) (Battery Backup)
    Output Voltage Tolerance
    +/- 2% static and 100% load step
    Output Voltage THD
    < 3% linear load and <5% non-linear load
    Overload Operation
    60 seconds @ 120% and 30 seconds @ 145%
    Required Output Current Protection
    250 A
    Bypass
    Built-in Maintenance Bypass
    Input
    Nominal Input Voltage
    400 3PH
    Input Frequency
    45 - 65 Hz
    Input Connections
    Hard Wire 5-wire (3PH + N + G)
    Input voltage range for main operations
    340 - 477 V
    Input voltage adjustable range for mains operation
    323 - 437 (380V)V , 340 - 460 (400V)V , 357 - 477 (415V)V
    Other Input Voltages
    380 , 415
    Maximum Input Current
    30 A
    Input Breaker Capacity
    63 A
    Input Total Harmonic Distortion
    Less than 5% for full load
    Type of Input Protection Required
    gL fuse
    Batteries & Runtime
    Battery Type
    Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
    Nominal Battery Voltage
    +/-192 V (split battery referenced to neutral)
    End of Discharge Battery Voltage
    +/-154 V
    Communications & Management
    Pre-Installed SmartSlot™ Cards
    AP9630
    Control panel
    Multi-function LCD status and control console
    Emergency Power Off (EPO)
    Yes
    Physical
    Maximum Height
    1300.0 mm
    Maximum Width
    500.0 mm
    Maximum Depth
    950.0 mm
    Net Weight
    360.0 kg
    Shipping Weight
    386.0 kg
    Shipping Height
    1440.0 mm
    Shipping Width
    800.0 mm
    Shipping Depth
    965.0 mm
    Environmental
    Operating Environment
    0 - 35 °C
    Operating Relative Humidity
    0 - 95 %
    Operating Elevation
    0-3000 meters
    Storage Temperature
    -10 - 60 °C
    Storage Relative Humidity
    0 - 95 %
    Storage Elevation
    0-9000 meters
    Audible noise at 1 meter from surface of unit
    53.600 dB
    Online Thermal Dissipation
    1212.000 BTU/hr
    Protection Class
    IP 20
    Conformance
    Approvals
    CE , EN/IEC 62040-1-1 , EN/IEC 62040-2 , EN/IEC 62040-3 , IEC 61000-4-5 , IEC 62040-2 , TUV , VFI-SS-111
    Standard warranty
    1 year on-site repair or replace with factory authorized Start-Up
    Sustainable Offer Status
    RoHS
    Compliant
    Battery Directive
    Compliant
  • View more View less

    Documents

    Language
    • All Languages51
    • English22
    • Chinese3
    • Dutch4
    • French5
    • German3
    • Italian5
    • Portuguese1
    • Russian4
    • Spanish4
    User guide
    Format
    Size
    Date
    Add to My Documents
    Galaxy 300 & Galaxy 300i 10-40 kVA Operation 380/400/415 V (Version 2)
    Description
    Providing the user with information on operation, maintenance and troubleshooting of the Galaxy 300 and 300i system
    prp.document.label.format pdf
    Size 5.9 MB
    Date 7/18/16
    Description
    Providing the user with information on operation, maintenance and troubleshooting of the Galaxy 300 and 300i system
    Galaxy 300/300i 10-40 kVA Receiving&Unpacking 380/400/415 V (Version 2)
    Description
    Providing information on storage conditions and how to unpack the galaxy 300 and 300i cabinets and remove them from the pallet
    prp.document.label.format pdf
    Size 5.1 MB
    Date 7/18/16
    Description
    Providing information on storage conditions and how to unpack the galaxy 300 and 300i cabinets and remove them from the pallet
    Galaxy 300 10-40 kVA 3:1 and 3:3 Installation Manual (Version 1)
    Description
    Providing the certified electrician with information on how to install and connect the Galaxy 300 UPS
    prp.document.label.format pdf
    Size 8.2 MB
    Date 1/29/16
    Description
    Providing the certified electrician with information on how to install and connect the Galaxy 300 UPS
    MGE Galaxy 3500, MGE Galaxy 300 and Smart-UPS VT Earthing Principles (Version 0)
    Description
    Contains information about earthing principles for MGE Galaxy 3500, Smart-UPS VT and MGE Galaxy 300
    prp.document.label.format pdf
    Size 2.2 MB
    Date 9/26/14
    Description
    Contains information about earthing principles for MGE Galaxy 3500, Smart-UPS VT and MGE Galaxy 300
    Schneider Electric Important Safety Instructions (Version 0)
    Description
    Schneider Electric Important Safety Instructions in English, Chinese Simplified, French, German, European Spanish, Italian, Russian, Portuguese Brazilian, Dutch, Japanese and Korean
    prp.document.label.format pdf
    Size 1.1 MB
    Date 6/6/14
    Description
    Schneider Electric Important Safety Instructions in English, Chinese Simplified, French, German, European Spanish, Italian, Russian, Portuguese Brazilian, Dutch, Japanese and Korean
    prp.document.label.format pdf
    Size 6 MB
    Date 7/18/16
    prp.document.label.format pdf
    Size 8.2 MB
    Date 1/29/16
    prp.document.label.format pdf
    Size 5.9 MB
    Date 7/18/16
    prp.document.label.format pdf
    Size 8.2 MB
    Date 1/29/16
    prp.document.label.format pdf
    Size 1.9 MB
    Date 7/18/16
    prp.document.label.format pdf
    Size 8.3 MB
    Date 1/29/16
    prp.document.label.format pdf
    Size 1.9 MB
    Date 7/18/16
    prp.document.label.format pdf
    Size 8.2 MB
    Date 1/29/16
    prp.document.label.format pdf
    Size 5.9 MB
    Date 7/18/16
    prp.document.label.format pdf
    Size 8.3 MB
    Date 1/29/16
    prp.document.label.format pdf
    Size 6 MB
    Date 7/18/16
    prp.document.label.format pdf
    Size 8.3 MB
    Date 1/29/16
    prp.document.label.format pdf
    Size 6 MB
    Date 7/18/16
    prp.document.label.format pdf
    Size 8.3 MB
    Date 1/29/16
    CAD
    Format
    Size
    Date
    Add to My Documents
    G3HT20K3I30 - MGE Galaxy 300, 20-30kVA, 400V, 3ph in 1ph Out (Version 3)
    Files in document
    pdf
    774.7 KB
    Description
    MGE Galaxy 300, Internal Battery, 3:1 Version, Mechanicals
    prp.document.label.format zip
    Size 3.4 MB
    Date 12/1/15
    Files in document
    pdf
    774.7 KB
    Description
    MGE Galaxy 300, Internal Battery, 3:1 Version, Mechanicals
    G3HT10K3I30C1M2-SD - Galaxy300 10-30kVA 3-1 One Module Capacity System One Line (Version 1)
    Files in document
    pdf
    259.7 KB
    Description
    MGE Galaxy 300, Internal Battery, System One Line
    prp.document.label.format zip
    Size 485.7 KB
    Date 5/3/11
    Files in document
    pdf
    259.7 KB
    Description
    MGE Galaxy 300, Internal Battery, System One Line
    G3HT10K3I30R2M1-SD - Galaxy300 10-30kVA 3-1 Two Module N+1 System One Line (Version 0)
    Files in document
    Description
    MGE Galaxy 300, Internal Battery, System One Line
    prp.document.label.format zip
    Size 513.1 KB
    Date 5/3/11
    Files in document
    Description
    MGE Galaxy 300, Internal Battery, System One Line
    G3HT10K3I30C1M1-SD - Galaxy300 10-30kVA 3-1 One Module Capacity System One Line (Version 0)
    Files in document
    pdf
    255.1 KB
    zip
    224.8 KB
    Description
    MGE Galaxy 300, Internal Battery, System One Line
    prp.document.label.format zip
    Size 479.9 KB
    Date 5/3/11
    Files in document
    pdf
    255.1 KB
    zip
    224.8 KB
    Description
    MGE Galaxy 300, Internal Battery, System One Line
    G3HT10K3I30R2M2-SD - Galaxy300 10-30kVA 3-1 Two Module N+1 System One Line (Version 1)
    Files in document
    pdf
    284 KB
    zip
    243.1 KB
    Description
    MGE Galaxy 300, Internal Battery, System One Line
    prp.document.label.format zip
    Size 527.1 KB
    Date 5/3/11
    Files in document
    pdf
    284 KB
    zip
    243.1 KB
    Description
    MGE Galaxy 300, Internal Battery, System One Line
    G3HT10K40-WD - Galaxy300 10-40kVA System Wiring Diagram (Version 0)
    Files in document
    pdf
    129.1 KB
    zip
    88.8 KB
    Description
    MGE Galaxy 300, Internal Battery, System Wiring Diagram
    prp.document.label.format zip
    Size 217.9 KB
    Date 6/17/10
    Files in document
    pdf
    129.1 KB
    zip
    88.8 KB
    Description
    MGE Galaxy 300, Internal Battery, System Wiring Diagram
    Brochure
    Format
    Size
    Date
    Add to My Documents
    Galaxy 300 Brochure (Version 0)
    Files in document
    pdf
    509.1 KB
    Description
    Galaxy 300 - 3 Phase power protection brochure
    prp.document.label.format zip
    Size 2.6 MB
    Date 11/12/15
    Files in document
    pdf
    509.1 KB
    Description
    Galaxy 300 - 3 Phase power protection brochure
    Galaxy 300 Brochure (Version 0)
    Description
    Galaxy 300 - La fiabilité en toute confiance
    prp.document.label.format pdf
    Size 784.2 KB
    Date 11/12/15
    Description
    Galaxy 300 - La fiabilité en toute confiance
    Galaxy 300: la protezione trifase da 10 a 80 kVA (Version 0)
    Files in document
    zip
    66.4 MB
    pdf
    827.2 KB
    Description
    Galaxy 300 offre una soluzione efficace e affidabile per proteggere piccole sale server, edifici commerciali e applicazioni industriali. La topologia on-line a doppia conversione garantisce una perfetta qualità dell’alimentazione, con zero tempo di trasferimento. Disponibile con batterie integrate o con batterie in armadio esterno per lunghe autonomie, l’UPS include sia un bypass statico che un bypass manuale e una possibilità di funzionamento in parallelo semplificata per maggiori livelli di disponibilità. La capacità di monitoraggio in locale e in remoto è ottenuta tramite una scheda di comunicazione integrata con un’interfaccia Web/SNMP facile da usare e un display intuitivo in 18 lingue. Sono disponibili le configurazioni trifase:trifase e trifase:monofase per una comoda distribuzione dellalimentazione.
    prp.document.label.format zip
    Size 67.2 MB
    Date 11/12/15
    Files in document
    zip
    66.4 MB
    pdf
    827.2 KB
    Description
    Galaxy 300 offre una soluzione efficace e affidabile per proteggere piccole sale server, edifici commerciali e applicazioni industriali. La topologia on-line a doppia conversione garantisce una perfetta qualità dell’alimentazione, con zero tempo di trasferimento. Disponibile con batterie integrate o con batterie in armadio esterno per lunghe autonomie, l’UPS include sia un bypass statico che un bypass manuale e una possibilità di funzionamento in parallelo semplificata per maggiori livelli di disponibilità. La capacità di monitoraggio in locale e in remoto è ottenuta tramite una scheda di comunicazione integrata con un’interfaccia Web/SNMP facile da usare e un display intuitivo in 18 lingue. Sono disponibili le configurazioni trifase:trifase e trifase:monofase per una comoda distribuzione dellalimentazione.
    Specification guide
    Format
    Size
    Date
    Add to My Documents
    Technical Specifications for Galaxy 300 & Galaxy 300i (Version 2)
    Description
    Providing information on technical data, facility planning, drawings, and options
    prp.document.label.format pdf
    Size 8.2 MB
    Date 7/31/16
    Description
    Providing information on technical data, facility planning, drawings, and options
    MGE Galaxy 300 - Battery Runtime charts (Version 0)
    Files in document
    pdf
    862.5 KB
    Description
    Battery runtime charts for standard non -modular battery configurations
    prp.document.label.format zip
    Size 3.5 MB
    Date 10/9/12
    Files in document
    pdf
    862.5 KB
    Description
    Battery runtime charts for standard non -modular battery configurations
    prp.document.label.format pdf
    Size 8.3 MB
    Date 7/31/16
    prp.document.label.format pdf
    Size 8.2 MB
    Date 7/31/16
    prp.document.label.format pdf
    Size 5.3 MB
    Date 7/31/16
    prp.document.label.format pdf
    Size 8.2 MB
    Date 7/31/16
    prp.document.label.format pdf
    Size 8.3 MB
    Date 7/31/16
    Certificate
    Format
    Size
    Date
    Add to My Documents
    Galaxy 300 Cmim Declaration of Conformity (Version 0)
    Description
    Cmim Declaration of Conformity
    prp.document.label.format pdf
    Size 123.6 KB
    Date 7/12/19