View all
TeSys GC, GY, GF

GC1610M5
-
Characteristics
Main range TeSysproduct name TeSys GCproduct or component type Modular contactordevice short name GC16contactor application Motor controlLightingHeatingComplementary utilisation category AC-7BAC-7Apoles description 1Ppower pole contact composition 1 NO[Ue] rated operational voltage <= 250 V AC[Ie] rated operational current 16 A AC-7A5 A AC-7Boperating position 30°/verticalcontrol circuit type AC at 50 Hz[Uc] control circuit voltage 220...240 V AC 50 Hz[Uimp] rated impulse withstand voltage 4 kV[Ith] conventional free air thermal current 16 A (at 50 °C) for power circuitIrms rated making capacity 40 A at 400 V AC for power circuit conforming to IEC 61095rated breaking capacity 40 A at 400 V for power circuit conforming to IEC 61095[Icw] rated short-time withstand current 128 A 40 °C - 10 s for power circuit40 A 40 °C - 30 s for power circuitassociated fuse rating 16 A gL at <= 440 V for power circuitaverage impedance 2.5 mOhm - Ith 16 A 50 Hz for power circuit[Ui] rated insulation voltage 500 V conforming to IEC 61095500 V conforming to VDE 0110electrical durability AC-7A: 100000 cyclesAC-7B: 100000 cyclespower dissipation per pole 0.65 Wcontrol type Remote controlmounting mode Clip-onmounting support DIN railstandards IEC 60947-5IEC 61095connections - terminals Control circuit: screw clamp terminals 1 cable(s) 2.5 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 2.5 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 2.5 mm²flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 1.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1.5 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1.5 mm²solid without cable endPower circuit: screw clamp terminals 1 cable(s) 6 mm²flexible without cable endPower circuit: screw clamp terminals 2 cable(s) 4 mm²flexible without cable endPower circuit: screw clamp terminals 1 cable(s) 6 mm²flexible with cable endPower circuit: screw clamp terminals 2 cable(s) 1.5 mm²flexible with cable endPower circuit: screw clamp terminals 1 cable(s) 6 mm²solid without cable endPower circuit: screw clamp terminals 2 cable(s) 4 mm²solid without cable endtightening torque Control circuit: 0.8 N.m - on screw clamp terminalsPower circuit: 0.8 N.m - on screw clamp terminalsoperating time 10...25 ms opening10...30 ms closingmechanical durability 1000000 cyclesmaximum operating rate 300 cyc/h 50 °Ccontrol circuit voltage limits Drop-out: 0.2...0.75 Uc at 50 Hz (at <50 °C)Operational: 0.85...1.1 Uc at 50 Hz (at <50 °C)inrush power in VA 15 VA 50 Hz (at 20 °C)hold-in power consumption in VA 3.8 VA 50 Hz (at 20 °C)heat dissipation 1.3 W at 50/60 HzEnvironment IP degree of protection IP40 conforming to VDE 0106 (in enclosure)IP20 conforming to VDE 0106protective treatment TCambient air temperature for operation -5…50 °Cambient air temperature for storage -40…70 °Coperating altitude <= 3000 mmechanical robustness Shocks contactor open: 10 Gn for 11 msShocks contactor closed: 15 Gn for 11 msVibrations contactor open: 2 Gn, 5...300 HzVibrations contactor closed: 3 Gn, 5...300 Hztotal number of 18 mm modules 1height 81 mmwidth 17.5 mmdepth 62.5 mmnet weight 0.11 kgquantity per set Set of 12colour WhiteOffer Sustainability Sustainable offer status Green Premium productREACh Regulation EU RoHS Directive Compliant
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation China RoHS declaration
Product out of China RoHS scope. Substance declaration for your informationEnvironmental Disclosure Circularity Profile No need of specific recycling operationsWEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages12
- English10
- French5
CatalogueFormatSizeAdd to My DocumentsTesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.Size pdfSize 111.5 MBDate 7/12/19DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.TeSys catalogue - 2019 - 2020 - chapter B8 contactors TeSys SK,K, D, SKGC, GC, GY,GF (Version 7.0)DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesSize pdfSize 12.2 MBDate 5/15/19DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesControl Panel Technical Guide - How to quickly design optimized contactor assemblies (Version 1.1)DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .Size pdfSize 15 MBDate 3/6/18DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .Catalogue TeSys 2019 - Composants pour protection et commande de moteurs (Version 7.1)DescriptionLe catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.Size pdfSize 108.2 MBDate 7/12/19DescriptionLe catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.Catalogue TeSys 2019 - Chapitre B8 - Contacteurs (Version 4.0)DescriptionPrésentation des gammes de contacteurs TeSys K, D. Gamme de mini contacteurs TeSys SK. Gamme de contacteurs modulaires Tesys GC, contateurs jour/nuit modulaires teSys GY, mini contacteurs modulaires TeSys SKGC, télérupteurs modulaires TeSys GF.Size pdfSize 12.3 MBDate 6/11/19DescriptionPrésentation des gammes de contacteurs TeSys K, D. Gamme de mini contacteurs TeSys SK. Gamme de contacteurs modulaires Tesys GC, contateurs jour/nuit modulaires teSys GY, mini contacteurs modulaires TeSys SKGC, télérupteurs modulaires TeSys GF.CADFormatSizeAdd to My DocumentsCAD file (on TraceParts) for GC1610M5: TeSys GC - modular contactor - 16 A - 1 NO - coil 220...240 V AC (Version 3.0)DescriptionYou will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.CAD file (on TraceParts) for GC1610M5: TeSys GC - modular contactor - 16 A - 1 NO - coil 220...240 V AC (Version 3.0)DescriptionYou will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.Modular contactor TeSys GC 16/25A 1NO (Version 1.0)Files in documentSize zipSize 462.7 KBDate 3/18/14Files in documentChina RoHS declarationFormatSizeAdd to My DocumentsTeSys GC - modular contactor - 16 A - 1 NO - coil 220...240 V ACDescriptionTeSys GC - modular contactor - 16 A - 1 NO - coil 220...240 V ACSize pdfSize 195.3 KBDate 12/10/19DescriptionTeSys GC - modular contactor - 16 A - 1 NO - coil 220...240 V ACDeclaration of conformityFormatSizeAdd to My DocumentsEU RoHS DeclarationFormatSizeAdd to My DocumentsTeSys GC - modular contactor - 16 A - 1 NO - coil 220...240 V ACDescriptionTeSys GC - modular contactor - 16 A - 1 NO - coil 220...240 V ACSize pdfSize 195.3 KBDate 12/10/19DescriptionTeSys GC - modular contactor - 16 A - 1 NO - coil 220...240 V ACProduct Environmental ProfileFormatSizeAdd to My DocumentsREACh DeclarationFormatSizeAdd to My DocumentsTeSys GC - modular contactor - 16 A - 1 NO - coil 220...240 V ACDescriptionTeSys GC - modular contactor - 16 A - 1 NO - coil 220...240 V ACSize pdfSize 195.3 KBDate 12/10/19DescriptionTeSys GC - modular contactor - 16 A - 1 NO - coil 220...240 V AC -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.