View all
TeSys GV3

GV3P256
GV3P256
Motor circuit breaker, TeSys GV3, 3P, 17-25 A, thermal magnetic, lugs terminals
Show more characteristics-
Characteristics
Main range TeSysproduct name TeSys GV3device short name GV3Pdevice application Motortrip unit technology Thermal-magneticComplementary poles description 3Pnetwork type ACutilisation category AC-3 conforming to IEC 60947-4-1Category A conforming to IEC 60947-2network frequency 50/60 Hz conforming to IEC 60947-4-1fixing mode 35 mm symmetrical DIN rail: clippedPanel: screwed (with 3 x M4 screws)operating position Any positionmotor power kW 18.5 kW at 690 V AC 50/60 Hz11 kW at 400/415 V AC 50/60 Hz15 kW at 500 V AC 50/60 Hzbreaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-26 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-212 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-250 % at 500 V AC 50/60 Hz conforming to IEC 60947-250 % at 690 V AC 50/60 Hz conforming to IEC 60947-2control type Rotary knob[In] rated current 25 Athermal protection adjustment range 17…25 Amagnetic tripping current 350 A[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2[Ith] conventional free air thermal current 25 A conforming to IEC 60947-4-1[Uimp] rated impulse withstand voltage IEC 60947-2 6 kVpower dissipation per pole 8 Wmechanical durability 50000 cycleselectrical durability 50000 cycles for AC-3 at 440 V Inmaximum operating rate 25 cyc/hrated duty Continuous conforming to IEC 60947-4-1connection pitch 17.5 mm without spreadersconnections - terminals Lugs-ring terminals external diameter: 6 mmBars 6 x 13.5 mmtightening torque 6 N.m on bars M6 screw type 6 N.m on lugs-ring terminals M6 screw typesuitability for isolation Yes conforming to IEC 60947-1phase failure sensitivity Yes conforming to IEC 60947-4-1height 132 mmwidth 55 mmdepth 136 mmnet weight 0.96 kgEnvironment standards EN/IEC 60947-2EN/IEC 60947-4-1CSA C22.2 No 60947-4-1UL 60947-4-1product certifications IECEE CB SchemeULCSACCCEACATEXBVLROS (Lloyds register of shipping)DNV-GLABSprotective treatment THIP degree of protection IP20 conforming to IEC 60529IK degree of protection IK09ambient air temperature for operation -20…60 °Cambient air temperature for storage -40…80 °Cfire resistance 960 °C conforming to IEC 60695-2-1operating altitude 3000 mOffer Sustainability Sustainable offer status Green Premium productREACh Regulation EU RoHS Directive Compliant
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation China RoHS declaration
Product out of China RoHS scope. Substance declaration for your informationEnvironmental Disclosure Circularity Profile No need of specific recycling operations
End of Life InformationWEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages10
- English11
- Chinese3
- French6
- German3
- Italian3
- Portuguese3
- Russian3
- Spanish3
User guideFormatSizeAdd to My DocumentsCADFormatSizeAdd to My DocumentsGV3P MOTOR CB THERM/MAG LUGS (Version 1.0)Files in documentSize zipSize 1.3 MBDate 12/18/17Files in documentInstruction sheetFormatSizeAdd to My DocumentsGV3 P..6/L..6 - Circuit breaker with lugs (Version 07)DescriptionGV3 P..6/L..6 - Circuit breaker with lugs - Instruction sheetSize pdfSize 2.2 MBDate 1/1/18DescriptionGV3 P..6/L..6 - Circuit breaker with lugs - Instruction sheetChina RoHS declarationFormatSizeAdd to My DocumentsMotor circuit breaker, TeSys GV3, 3P, 17-25 A, thermal magnetic, lugs terminalsDescriptionMotor circuit breaker, TeSys GV3, 3P, 17-25 A, thermal magnetic, lugs terminalsSize pdfSize 195.3 KBDate 12/8/19DescriptionMotor circuit breaker, TeSys GV3, 3P, 17-25 A, thermal magnetic, lugs terminalsDeclaration of conformityFormatSizeAdd to My DocumentsEnd of Life InformationFormatSizeAdd to My DocumentsEU RoHS DeclarationFormatSizeAdd to My DocumentsMotor circuit breaker, TeSys GV3, 3P, 17-25 A, thermal magnetic, lugs terminalsDescriptionMotor circuit breaker, TeSys GV3, 3P, 17-25 A, thermal magnetic, lugs terminalsSize pdfSize 195.3 KBDate 12/8/19DescriptionMotor circuit breaker, TeSys GV3, 3P, 17-25 A, thermal magnetic, lugs terminalsProduct Environmental ProfileFormatSizeAdd to My DocumentsTeSys GV3 motor circuit breakers (Version 3.0)DescriptionNoneSize pdfSize 272 KBDate 12/21/15DescriptionNoneREACh DeclarationFormatSizeAdd to My DocumentsMotor circuit breaker, TeSys GV3, 3P, 17-25 A, thermal magnetic, lugs terminalsDescriptionMotor circuit breaker, TeSys GV3, 3P, 17-25 A, thermal magnetic, lugs terminalsSize pdfSize 195.3 KBDate 12/8/19DescriptionMotor circuit breaker, TeSys GV3, 3P, 17-25 A, thermal magnetic, lugs terminals -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Performance Curves
Thermal-Magnetic Tripping CurvesAverage Operating Times at 20 °C Related to Multiples of the Setting Current
1a3 poles from cold state (Ir minimum): GV3P1b3 poles from cold state (Ir maximum): GV3P2a3 poles from hot state (Ir minimum): GV3P2b3 poles from hot state (Ir maximum): GV3PCurrent Limitation on Short-Circuit (3-Phase 400/415 V)Dynamic Stress
I peak = f (prospective Isc) at 1.05 Ue = 435 V
1Maximum peak current270-80 A (GV3P80), 62-73 A (GV3P73)348-65 A (GV3P65)437-50 A (GV3P50)530-40 A (GV3P40)623-32 A (GV3P32)717-25 A (GV3P25)812-18 A (GV3P18)99-13 A (GV3P13)Maximum Thermal Limit on Short-CircuitThermal Limit in kA2s in the Magnetic Operating Zone
Sum of I2dt = f (prospective Isc) at 1.05 Ue = 435 V
170-80 (GV3P80) - 62-73 (GV3P73)248-65 A (GV3P65)337-50 A (GV3P50)430-40 A (GV3P40)523-32 A (GV3P32)617-25 A (GV3P25)712-18 A (GV3P18)89-13 A (GV3P13) -
Dimensions Drawings
GVl3L, GV3PDimensions
(1)Blocks GVAN●●, GVAD●● and GVAM11.(2)Blocks GV3AU●● and GV3AS●●.X1 = Electrical clearance (ISC max) 40 mm for Ue ≤ 500 V, 50 mm for Ue ≤ 690 V
NOTE: Leave a space of 9 mm between 2 circuit breakers: either an empty space or side-mounting add-on contact blocks. Side by side mounting is possible up to 40 °C.
Mounting on Rail AM1 DE200 or AM1 ED201
Panel Mounting, using M4 Screws
Mounting on Pre-Slotted Plate AM1 PA
-
Connections and Schema
GV3P••