  • Main
    range of product
    Harmony SCU
    product or component type
    Controller
    device presentation
    Basic element
    Complementary
    supply
    External source
    [Us] rated supply voltage
    24 V (20.4…28.8 V)DC
    immunity to microbreaks
    10 ms
    inrush current
    30 A
    power consumption in W
    15 W
    local signalling
    No indicator
    number of pages
    Limited by internal memory capacity
    software designation
    SoMachine
    operating system
    Harmony
    processor name
    CPU RISC
    processor frequency
    333 MHz
    memory description
    Flash NAND, 128 MB
    Internal data storage FRAM, 128 kB
    Application run DRAM, 128 MB
    integrated connection type
    1 serial link - RJ45 - RS232/RS485 (rate: <= 115.2 kbits/s)
    1 Ethernet TCP/IP - RJ45
    1 USB 2.0 type mini B
    1 USB 2.0 type A
    CANopen master bus - SUB-D 9
    realtime clock
    Built-in
    downloadable protocols
    Modbus
    CANopen
    Modbus TCP/IP
    fixing mode
    By 1 nut - diameter: Ø 22 mm, mounting on: 1...6 mm thick panel
    enclosure material
    PC/PBT
    shock resistance
    147 m/s² for 11 ms (on DIN rail) conforming to IEC 60068-2-27
    294 m/s² for 6 ms (on panel mounting) conforming to IEC 60068-2-27
    vibration resistance
    +/- 3.5 mm (f = 5…9 Hz) conforming to IEC 60068-2-6
    1 gn (f = 9…150 Hz) conforming to IEC 60068-2-6
    electromagnetic compatibility
    Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2
    Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2
    Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz...3 GHz) conforming to IEC 61000-4-3
    Electrical fast transient/burst immunity test - test level: 2 kV (power lines) conforming to IEC 61000-4-4
    Electrical fast transient/burst immunity test - test level: 1 kV (between analogue I/O and operating voltage) conforming to IEC 61000-4-4
    Electrical fast transient/burst immunity test - test level: 2 kV (relay wires) conforming to IEC 61000-4-4
    Electrical fast transient/burst immunity test - test level: 1 kV (Ethernet line) conforming to IEC 61000-4-4
    Electrical fast transient/burst immunity test - test level: 1 kV (COM line) conforming to IEC 61000-4-4
    Electrical fast transient/burst immunity test - test level: 1 kV (CAN line) conforming to IEC 61000-4-4
    Surge immunity test - test level: 2 kV (power supply (common mode)) conforming to IEC 61000-4-5
    Surge immunity test - test level: 1 kV (power supply (differential mode)) conforming to IEC 61000-4-5
    Surge immunity test - test level: 1 kV common mode (digital I/O) conforming to IEC 61000-4-5
    Surge immunity test - test level: 0.5 kV differential mode (digital I/O) conforming to IEC 61000-4-5
    Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6
    Conducted emission - test level: 150 kHz...30 MHz conforming to EN 55011
    Radiated emission - test level: 30 MHz...1 GHz conforming to EN 55011
    discrete input number
    2 for fast input (normal mode) conforming to IEC 61131-2 Type 1
    6 for digital input conforming to IEC 61131-2 Type 1
    discrete input voltage
    24 V DC, discrete input logic: sink or source (positive/negative)
    number of common point
    1 for fast input (HSC mode)
    1 for digital input
    discrete input current
    7.83 mA for fast input
    5 mA for digital
    input impedance
    2.81 kOhm
    4.7 kOhm
    sensor power supply
    15…28.8 V DC >= 15 V, current (state 1): >= 5 mA <= 5 V, current (state 0): <= 1.5 mA
    15…28.8 V DC >= 15 V, current (state 1): >= 2.5 mA <= 5 V, current (state 0): <= 1 mA
    configurable filtering time
    0 ms no filter (none)
    0.004...0.04 ms bounce filter (latch/event and cumulative filter by step Nx0.5ms (64>=N>=2))
    3...12 ms integrator (none/run/stop)
    maximum input frequency
    100 kHz for fast input (encoder mode) - control type A/B
    100 kHz for fast input - control type single phase
    100 kHz for fast input - control type pulse/direction
    maximum cable distance between devices
    Shielded cable: <10 m for fast input
    Shielded cable: <100 m for digital input
    Unshielded cable: <50 m for digital input
    connection pitch
    3.5 mm
    overvoltage protection
    With overvoltage protection
    isolation between channels and internal logic
    500 V DC
    isolation between channels
    None
    discrete output number
    2 fast output (normal mode), output logic: source
    6 digital output, output logic: source
    discrete output voltage
    24 V DC (voltage limit: 19.2...28.8 V) with transistor discrete output(s)
    24 V DC (voltage limit: 5...30 V) with relay discrete output(s)
    220 V AC (voltage limit: 100...250 V) with relay discrete output(s)
    input/output number
    2 for fast input, terminal(s): FI0...FI1
    2 for fast output, terminal(s): FQ0...FQ1
    6 for digital input, terminal(s): DI0...DI5
    6 for digital output, terminal(s): DQ0...DQ5
    discrete output current
    2 A 4 A), response time 5 ms with opening contact for digital output
    2 A 4 A), response time 2 ms with closing contact for digital output
    300 mA, response time 2 ms for fast output (normal mode)
    50 mA, response time 2 ms for fast output (PWM or PTO mode)
    insulation resistance
    > 10 MOhm between the I/O and internal logic
    > 10 MOhm between power supply and earth
    maximum output frequency
    100 kHz for fast output (PTO mode)
    1 kHz for fast output (PWM mode)
    absolute accuracy error
    +/- 0.1 % of full scale cyclic ratio 1...99% for fast output (PWM or PTO mode)
    1 % of full scale cyclic ratio 1...99% for fast output (PWM or PTO mode)
    +/- 5 % of full scale cyclic ratio 10...90% for fast output (PWM or PTO mode)
    +/- 10 % of full scale cyclic ratio 20...80% for fast output (PWM or PTO mode)
    +/- 15 % of full scale cyclic ratio 30...70% for fast output (PWM or PTO mode)
    analogue input number
    2 for analog input
    2 for RTDs
    analogue input range
    0...20 mA/4...20 mA - resolution: 12 bits, input impedance: 250 Ohm (tolerance: +/- 1 %)
    -10...+10 V or 0...10 V - resolution: 12 bits + sign, input impedance: >= 1 MOhm
    analogue input type
    RTD at - 200...600 °C - resolution: 16 bits temperature probe: Pt 100/Pt 1000
    RTD at - 50...200 °C - resolution: 16 bits temperature probe: Ni 100/Ni 1000
    RTD at - 200...760 °C - resolution: 16 bits (thermocouple J)
    RTD at - 240...1370 °C - resolution: 16 bits (thermocouple K)
    RTD at 0...1600 °C - resolution: 16 bits (thermocouple R)
    RTD at 200...1800 °C - resolution: 16 bits (thermocouple B)
    RTD at 0...1600 °C - resolution: 16 bits (thermocouple S)
    RTD at - 200...400 °C - resolution: 16 bits (thermocouple T)
    RTD at - 200...900 °C - resolution: 16 bits (thermocouple E)
    RTD at - 200...1300 °C - resolution: 16 bits (thermocouple N)
    analogue output number
    2 resistive load for 12 bits + sign
    analogue output range
    0...20 mA/4...20 mA (> 300 Ohm) for open-circuit
    -10...10 V/0...10 V (> 2 kOhm) for short-circuit
    height
    50.65 mm
    width
    128 mm
    depth
    102 mm
    net weight
    0.398 kg
    Environment
    standards
    UL 508
    FCC Class A
    EN 61131-2
    WEEE directive 2002/96/EC
    CSA C22.2 No 213 Class I Division 2
    ANSI/ISA 12-12-01
    RoHS compliant
    RoHS China SJ/T 11363-2006
    IEC 61000-6-2
    product certifications
    CULus 508
    CUL 1604 Class 1 Division 2
    C-Tick
    CULus CSA 22-2 No 142
    GOST
    KCC
    marking
    CE
    ambient air temperature for operation
    0…50 °C
    ambient air temperature for storage
    -20…60 °C
    relative humidity
    5…85 % without condensation
    operating altitude
    <= 2000 m
    storage altitude
    0…10000 m
    maximum pressure
    800...1114 hPa
    IP degree of protection
    IP20 (rear panel) conforming to IEC 60529
    IP65 (front panel) conforming to IEC 60529
    NEMA degree of protection
    NEMA 4X front panel
    pollution degree
    2 conforming to IEC 60664
    environmental characteristic
    Corrosive gas free
    Packing Units
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Weight
    866 g
    Package 1 Height
    18.5 cm
    Package 1 width
    27 cm
    Package 1 Length
    9.5 cm
    Unit Type of Package 2
    S03
    Number of Units in Package 2
    6
    Package 2 Weight
    5.3 kg
    Package 2 Height
    30 cm
    Package 2 width
    30 cm
    Package 2 Length
    40 cm
    Unit Type of Package 3
    PAL
    Number of Units in Package 3
    48
    Package 3 Weight
    43.08 kg
    Package 3 Height
    70 cm
    Package 3 width
    60 cm
    Package 3 Length
    80 cm
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
  • View more View less

    Documents

    Language
    • All Languages25
    • English17
    • Chinese7
    • French7
    • German6
    • Italian6
    • Portuguese6
    • Spanish6
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    Catalog Harmony SCU HMI controllers for simple machines English 04/20 (Version 5.0)
    Description
    Discover catalog for Harmony SCU HMI controllers for simple machines
    prp.document.label.format pdf
    Size 2.9 MB
    Date 4/21/20
    Description
    Discover catalog for Harmony SCU HMI controllers for simple machines
    prp.document.label.format pdf
    Size 3.3 MB
    Date 5/28/20
    User guide
    Format
    Size
    Date
    Add to My Documents
    Harmony SCU HMI Controller, Hardware Guide (Version 07)
    Description
    The purpose of this document is to:- Show you how to install and operate your HMI controller.- Show you how to connect the HMI controller to a programming device equipped with SoMachine software.- Help you understand how to interface the HMI controller and other devices.- Help you become familiar with the HMI controller features.
    prp.document.label.format pdf
    Size 5.5 MB
    Date 11/1/19
    Description
    The purpose of this document is to:- Show you how to install and operate your HMI controller.- Show you how to connect the HMI controller to a programming device equipped with SoMachine software.- Help you understand how to interface the HMI controller and other devices.- Help you become familiar with the HMI controller features.
    Harmony SCU - HMI Controller, Quick Reference Guide (Version 04)
    Description
    This document contains information on installation, wiring principles, communication ports, data transfers, and driver installation for Magelis SCU HMI controllers.
    prp.document.label.format pdf
    Size 8.5 MB
    Date 11/1/19
    Description
    This document contains information on installation, wiring principles, communication ports, data transfers, and driver installation for Magelis SCU HMI controllers.
    Magelis SCU - HMI Controller, Quick Reference Guide (Version 00)
    Description
    This guide contains information on installation, wiring principles, grounding, and communication ports for Magelis SCU HMI controllers.
    prp.document.label.format pdf
    Size 7.8 MB
    Date 3/1/13
    Description
    This guide contains information on installation, wiring principles, grounding, and communication ports for Magelis SCU HMI controllers.
    prp.document.label.format pdf
    Size 5.5 MB
    Date 11/1/19
    prp.document.label.format pdf
    Size 3.4 MB
    Date 10/1/14
    prp.document.label.format pdf
    Size 5.8 MB
    Date 11/1/19
    prp.document.label.format pdf
    Size 5.8 MB
    Date 11/1/19
    prp.document.label.format pdf
    Size 5.3 MB
    Date 11/1/19
    prp.document.label.format pdf
    Size 5.7 MB
    Date 10/1/14
    prp.document.label.format pdf
    Size 5.5 MB
    Date 11/1/19
    Certificate
    Format
    Size
    Date
    Add to My Documents
    HazLoc_UL_NRAG.E486185 _ALL_JUL2018 (Version 1.0)
    Description
    Hazardous location Class I Division 2 by UL for US
    prp.document.label.format pdf
    Size 150.6 KB
    Date 8/7/18
    Description
    Hazardous location Class I Division 2 by UL for US
    HazLoc_cUL_NRAG7.E486185 _ALL_JUL2018 (Version 1.0)
    Description
    Hazardous location Class I Division 2 by UL for Canada
    prp.document.label.format pdf
    Size 153.9 KB
    Date 8/7/18
    Description
    Hazardous location Class I Division 2 by UL for Canada
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    Magelis HMISTU and HMISCU Terminals ATEX/IECEx, Instruction Guide (Version 01)
    Description
    This present document applies when the Magelis HMISTU and HMISCU terminals are used in hazardous areas and contains instructions for installation, operation, maintenance or evolution of your system.
    prp.document.label.format pdf
    Size 157.1 KB
    Date 5/1/16
    Description
    This present document applies when the Magelis HMISTU and HMISCU terminals are used in hazardous areas and contains instructions for installation, operation, maintenance or evolution of your system.
    HMIZSURDP.. Remote Controller Module Connection Cable, Instruction Sheet (Version 01)
    Description
    This document contains installation instructions and diagrams for the HMIZSURDP remote controller module connection cable.
    prp.document.label.format pdf
    Size 1.1 MB
    Date 9/1/14
    Description
    This document contains installation instructions and diagrams for the HMIZSURDP remote controller module connection cable.
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    HMISBC : HMISBC_ROHS_CHINA_DECLARATION
    Description
    HMISBC_ROHS_CHINA_DECLARATION
    prp.document.label.format pdf
    Size 195.3 KB
    Date 8/6/20
    Description
    HMISBC_ROHS_CHINA_DECLARATION
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    DCE_HMISCU_STU_APR2019 (Version 00)
    Description
    EU Declaration of Conformity
    prp.document.label.format pdf
    Size 2.3 MB
    Date 4/5/19
    Description
    EU Declaration of Conformity
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 126.7 KB
    Date 6/1/14
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    HMISBC : HMISBC_ROHS_DECLARATION
    Description
    HMISBC_ROHS_DECLARATION
    prp.document.label.format pdf
    Size 195.3 KB
    Date 8/6/20
    Description
    HMISBC_ROHS_DECLARATION
    Marine certificate
    Format
    Size
    Date
    Add to My Documents
    LR_C1210041E2_GTO_STO_SCU_STU_XBTGT (Version 1.0)
    Description
    Type Approval Certificate by Lloyd's Register
    prp.document.label.format pdf
    Size 327.3 KB
    Date 4/24/17
    Description
    Type Approval Certificate by Lloyd's Register
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 6.7 MB
    Date 5/1/14
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.