View all
Harmony K

K2H014UCH
-
Characteristics
Main range of product Harmony Kproduct or component type Complete cam switchcomponent name K2[Ith] conventional free air thermal current 20 Aproduct mounting Front mountingfixing mode Ø 22 mm holecam switch head type With front plate 45 x 45 mmtype of operator Black handle, length = 35 mmrotary handle padlocking Withoutpresentation of legend With metallic legend, 1 - 2 black markingcam switch function Changeover switchreturn Withoutoff position Without Off positionpoles description 4Pswitching positions Left: 330°Right: 30°IP degree of protection IP65 conforming to IEC 529IP65 conforming to NF C 20-010Complementary switching angle 30 °[Ui] rated insulation voltage 690 V (pollution degree 3) conforming to IEC 60947-1[Ithe] conventional enclosed thermal current 16 Aelectrical durability 200000 cycles AC-23200000 cycles AC-3600000 cycles AC-15600000 cycles AC-21maximum operating rate 2.5 cyc/mn AC-212.5 cyc/mn AC-232.5 cyc/mn AC-38.333 cyc/mn AC-15short-circuit current 10000 Ashort-circuit protection 20 A cartridge fuse, type gG[Uimp] rated impulse withstand voltage 4 kV in isolating function6 kV conforming to IEC 947-1contact operation Slow-breakpositive opening Withelectrical connection Captive screw clamp terminals flexible, clamping capacity: 2 x 1.5 mm²Captive screw clamp terminals solid, clamping capacity: 1 x 2.5 mm²mechanical durability 1000000 cyclesCAD overall width 45 mmCAD overall height 50 mmCAD overall depth 79 mmnet weight 0.215 kgEnvironment standards EN 60947-3 for power circuitEN 60947-5-1 for control circuitIEC 60947-3 for power circuitIEC 60947-5-1 for control circuitCENELEC EN 50013product certifications CSA 240 V 3 hp 3 phases 2 pole(s)UL 240 V 0.33 hp 1 phase 2 pole(s)CSA 240 V 1 hp 1 phaseUL 240 V 1 hp 3 phasesprotective treatment TCambient air temperature for operation -25…55 °Cambient air temperature for storage -40…70 °Cshock resistance 30 gn conforming to IEC 68-2-27vibration resistance 5 gn conforming to IEC 68-2-6 (f = 10…150 Hz)electrical shock protection class Class II conforming to IEC 536Class II conforming to NF C 20-030Offer Sustainability Sustainable offer status Green Premium productREACh Regulation REACh free of SVHC YesEU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS DeclarationToxic heavy metal free YesMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure Circularity Profile No need of specific recycling operationsWEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages8
- English7
- French4
- German3
- Italian3
- Kazakh3
- Russian3
- Spanish3
CatalogueFormatSizeAdd to My DocumentsCADFormatSizeAdd to My DocumentsCam switches, operating heads (Version 1.0)Files in documentSize zipSize 78.7 KBDate 11/23/07Files in documentCam switches, complete switches, 12 and 20 A, front mounting, by dia 22 mm hole, 45 x 45 mm front plate, 35 mm handle (Version 1.0)Files in documentSize zipSize 119.6 KBDate 11/23/07Files in documentInstruction sheetFormatSizeAdd to My DocumentsEU RoHS DeclarationFormatSizeAdd to My Documentscam changeover switch - 4-pole - 90° - 20 A - for Ø 22 mmDescriptioncam changeover switch - 4-pole - 90° - 20 A - for Ø 22 mmSize pdfSize 195.3 KBDate 12/7/19Descriptioncam changeover switch - 4-pole - 90° - 20 A - for Ø 22 mmREACh DeclarationFormatSizeAdd to My Documentscam changeover switch - 4-pole - 90° - 20 A - for Ø 22 mmDescriptioncam changeover switch - 4-pole - 90° - 20 A - for Ø 22 mmSize pdfSize 195.3 KBDate 12/7/19Descriptioncam changeover switch - 4-pole - 90° - 20 A - for Ø 22 mmChina RoHS declarationFormatSizeAdd to My Documentscam changeover switch - 4-pole - 90° - 20 A - for Ø 22 mmDescriptioncam changeover switch - 4-pole - 90° - 20 A - for Ø 22 mmSize pdfSize 195.3 KBDate 12/7/19Descriptioncam changeover switch - 4-pole - 90° - 20 A - for Ø 22 mm -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
Operating Head and Body with Plastic BaseFront Mounting by Ø 22 mm/0.87 in. Holea1100.5 mm/3.96 in.esupport panel thickness 1 mm to 6 mm./0.039 in. to 0.24 in. -
Technical Description
Link Positions (Factory Mounted)Diagram for 1 to 4-pole SwitchesSelect the number of poles according to the product characteristics.
MarkingAngular Position of SwitchSwitching ProgramDiagram for 1 to 4-pole SwitchesSelect the number of poles according to the product characteristics.
(1)1-pole(2)2-pole(3)3-pole(4)4-poleConvention Used for Switching Program RepresentationContact closed
Contact closed in 2 positions and maintained between the 2 positions
Sealed assembly for auto-maintain control
Overlapping contacts
Spring return position: for a switching angle of 90°, spring return is over 30° after the last position (for a maximum of 3 simultaneous contacts).