  • Main
    product or component type
    Power add-on block
    device short name
    LA1SK
    utilisation category for power pole
    AC-1
    AC-3
    power pole contact composition
    1P
    pole contact composition
    1 NO
    [Ue] rated operational voltage
    Signalling circuit: 690 V AC <= 400 Hz
    Power circuit: 690 V AC 50/60 Hz
    [Ie] rated operational current
    6 A at <= 440 V AC AC-3 for power circuit
    12 A (at <55 °C) AC AC-1 for power circuit
    auxiliary contact composition
    1 NO
    [Ith] conventional free air thermal current
    12 A (at 55 °C) for power circuit
    10 A (at 55 °C) for signalling circuit
    Irms rated making capacity
    66 A at 690 V AC conforming to IEC 60947
    66 A at 690 V AC conforming to NF C 63-110
    [Icw] rated short-time withstand current
    50 A 55 °C for power circuit
    associated fuse rating
    10 A gI for signalling circuit conforming to VDE 0660
    [Ui] rated insulation voltage
    690 V conforming to IEC 60947
    690 V conforming to VDE 0110 group C
    690 V conforming to BS 5424
    690 V conforming to UL 508
    690 V conforming to CSA C22.2 No 14
    standards
    IEC 60947
    VDE 0660
    NF C 63-110
    BS 5424
    product certifications
    UL
    CSA
    connections - terminals
    Connector 1 cable(s) 0.35…6 mm²flexible with cable end
    Connector 1 cable(s) 0.5…6 mm²flexible without cable end
    Connector 1 cable(s) 1.5…6 mm²solid
    Connector 2 cable(s) 0.35…1.5 mm²flexible with cable end
    Connector 2 cable(s) 0.35…2.5 mm²flexible without cable end
    Connector 2 cable(s) 1.5…4 mm²solid
    tightening torque
    0.8 N.m - on connector - with screwdriver pozidriv No 1
    Complementary
    signalling circuit frequency
    <= 400 Hz
    net weight
    0.022 kg
    Environment
    IP degree of protection
    IP2x conforming to VDE 0106
    protective treatment
    TC conforming to IEC 60068
    TC conforming to DIN 50015
    ambient air temperature for operation
    -20…50 °C
    ambient air temperature for storage
    -50…70 °C
    operating altitude
    2000 m without derating
    Packing Units
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Weight
    27 g
    Package 1 Height
    3.7 cm
    Package 1 width
    4.3 cm
    Package 1 Length
    5.5 cm
    Unit Type of Package 2
    S01
    Number of Units in Package 2
    60
    Package 2 Weight
    1.845 kg
    Package 2 Height
    15 cm
    Package 2 width
    15 cm
    Package 2 Length
    40 cm
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh free of SVHC
    Yes
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information
    Environmental Disclosure
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages8
    • English7
    • French4
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    TeSys - Catalogue 2020 - Innovative and connected solutions for motor starters (Version 10.0)
    Description
    Ready-to-use motor starters and all components for building specific motor starters ( circuit breakers, contactors, overload relays , accessories ...). This edition includes a presentation of the new TeSys island system. The catalogue can also be downloaded chapter per chapter.
    prp.document.label.format pdf
    Size 118.2 MB
    Date 7/22/20
    Description
    Ready-to-use motor starters and all components for building specific motor starters ( circuit breakers, contactors, overload relays , accessories ...). This edition includes a presentation of the new TeSys island system. The catalogue can also be downloaded chapter per chapter.
    TeSys catalogue - 2020 - chapter B8 contactors TeSys SK,K, D, SKGC, GC, GY,GF (Version 8.0)
    Description
    Contactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessories
    prp.document.label.format pdf
    Size 16.1 MB
    Date 7/22/20
    Description
    Contactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessories
    prp.document.label.format pdf
    Size 108.2 MB
    Date 7/12/19
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 1.6 MB
    Date 10/1/12
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    LA1SK10 : LA1SK10_ROHS_CHINA_DECLARATION
    Description
    LA1SK10_ROHS_CHINA_DECLARATION
    prp.document.label.format pdf
    Size 195.3 KB
    Date 9/30/20
    Description
    LA1SK10_ROHS_CHINA_DECLARATION
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    LA1SK10 : TeSys SK - Power add on block - 1 NO Power - 1 NO Signalling
    Description
    TeSys SK - Power add on block - 1 NO Power - 1 NO Signalling
    prp.document.label.format pdf
    Size 195.3 KB
    Date 9/30/20
    Description
    TeSys SK - Power add on block - 1 NO Power - 1 NO Signalling
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.