View all
TeSys D

LC1D0965GD
LC1D0965GD
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 125 V DC coil
Show more characteristics
has not been replaced. Please contact your customer care center for more information.
-
Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Contactordevice short name LC1Dcontactor application Motor controlResistive loadutilisation category AC-1AC-3poles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 HzPower circuit: <= 300 V DC[Ie] rated operational current 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit25 A (at <60 °C) at <= 440 V AC AC-1 for power circuitmotor power kW 2.2 kW at 220...230 V AC 50/60 Hz4 kW at 380...400 V AC 50/60 Hz4 kW at 415...440 V AC 50/60 Hz5.5 kW at 500 V AC 50/60 Hz5.5 kW at 660...690 V AC 50/60 Hzmotor power HP (UL / CSA) 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors2 hp at 200/208 V AC 50/60 Hz for 3 phases motors2 hp at 230/240 V AC 50/60 Hz for 3 phases motors5 hp at 460/480 V AC 50/60 Hz for 3 phases motors7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors0.33 hp at 115 V AC 50/60 Hz for 1 phase motorscontrol circuit type DC standard[Uc] control circuit voltage 125 V DCauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947overvoltage category III[Ith] conventional free air thermal current 25 A (at 60 °C) for power circuit10 A (at 60 °C) for signalling circuitIrms rated making capacity 250 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947[Icw] rated short-time withstand current 105 A 40 °C - 10 s for power circuit210 A 40 °C - 1 s for power circuit30 A 40 °C - 10 min for power circuit61 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuitassociated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-125 A gG at <= 690 V coordination type 1 for power circuit20 A gG at <= 690 V coordination type 2 for power circuitaverage impedance 2.5 mOhm - Ith 25 A 50 Hz for power circuit[Ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1Power circuit: 600 V CSA certifiedPower circuit: 600 V UL certifiedSignalling circuit: 690 V conforming to IEC 60947-1Signalling circuit: 600 V CSA certifiedSignalling circuit: 600 V UL certifiedelectrical durability 0.6 Mcycles 25 A AC-1 at Ue <= 440 V2 Mcycles 9 A AC-3 at Ue <= 440 Vpower dissipation per pole 1.56 W AC-10.2 W AC-3safety cover Withoutmounting support PlateRailstandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications ULLROS (Lloyds register of shipping)RINADNVCCCCSABVGLGOSTconnections - terminals Control circuit: lugs-ring terminals (external diameter: 8 mm) Power circuit: lugs-ring terminals (external diameter: 8 mm)tightening torque Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5Power circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver flat Ø 8 mm M3.5Power circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5operating time 53.55...72.45 ms closing16...24 ms openingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 30 Mcyclesmaximum operating rate 3600 cyc/h 60 °CComplementary coil technology Built-in bidirectional peak limiting diode suppressorcontrol circuit voltage limits Drop-out: 0.1...0.25 Uc DC (at 60 °C)Operational: 0.7...1.25 Uc DC (at 60 °C)time constant 28 msinrush power in W 5.4 W (at 20 °C)hold-in power consumption in W 5.4 W at 20 °Cauxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA for signalling circuitminimum switching voltage 17 V for signalling circuitnon-overlap time 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm for signalling circuitEnvironment IP degree of protection IP20 front face conforming to IEC 60529protective treatment TH conforming to IEC 60068-2-30pollution degree 3ambient air temperature for operation -5…60 °Cambient air temperature for storage -60…80 °Cpermissible ambient air temperature around the device -40…70 °C at Ucoperating altitude 3000 m withoutfire resistance 850 °C conforming to IEC 60695-2-1flame retardance V1 conforming to UL 94mechanical robustness Vibrations contactor open: 2 Gn, 5...300 HzVibrations contactor closed: 4 Gn, 5...300 HzShocks contactor open: 10 Gn for 11 msShocks contactor closed: 15 Gn for 11 msheight 77 mmwidth 45 mmdepth 93 mmnet weight 0.48 kgContractual warranty Warranty 18 months -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.