View all
TeSys D

LC1D40A6FE7
LC1D40A6FE7
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 115 V AC 50/60 Hz coil
Show more characteristics-
Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Contactordevice short name LC1Dcontactor application Motor controlResistive loadutilisation category AC-1AC-3AC-4poles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 HzPower circuit: <= 300 V DC[Ie] rated operational current 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit40 A (at <60 °C) at <= 440 V AC AC-3 for power circuitmotor power kW 18.5 kW at 380...400 V AC 50/60 Hz (AC-3)11 kW at 220...230 V AC 50/60 Hz (AC-3)22 kW at 415...440 V AC 50/60 Hz (AC-3)22 kW at 500 V AC 50/60 Hz (AC-3)30 kW at 660...690 V AC 50/60 Hz (AC-3)9 kW at 400 V AC 50/60 Hz (AC-4)motor power HP (UL / CSA) 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors10 hp at 230/240 V AC 50/60 Hz for 3 phases motors30 hp at 575/600 V AC 50/60 Hz for 3 phases motors10 hp at 200/208 V AC 50/60 Hz for 3 phases motors3 hp at 115 V AC 50/60 Hz for 1 phase motors30 hp at 460/480 V AC 50/60 Hz for 3 phases motorscontrol circuit type AC at 50/60 Hz[Uc] control circuit voltage 115 V AC 50/60 Hzauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947overvoltage category III[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit60 A (at 60 °C) for power circuitIrms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1800 A at 440 V for power circuit conforming to IEC 60947rated breaking capacity 800 A at 440 V for power circuit conforming to IEC 60947[Icw] rated short-time withstand current 320 A 40 °C - 10 s for power circuit720 A 40 °C - 1 s for power circuit72 A 40 °C - 10 min for power circuit165 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuitassociated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-180 A gG at <= 690 V coordination type 1 for power circuit80 A gG at <= 690 V coordination type 2 for power circuitaverage impedance 1.5 mOhm - Ith 60 A 50 Hz for power circuit[Ui] rated insulation voltage Power circuit: 600 V CSA certifiedPower circuit: 600 V UL certifiedSignalling circuit: 690 V conforming to IEC 60947-1Signalling circuit: 600 V CSA certifiedSignalling circuit: 600 V UL certifiedPower circuit: 690 V conforming to IEC 60947-4-1electrical durability 1.4 Mcycles 60 A AC-1 at Ue <= 440 V1.5 Mcycles 40 A AC-3 at Ue <= 440 Vpower dissipation per pole 2.4 W AC-35.4 W AC-1safety cover Withmounting support RailPlatestandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications CCCGOSTCSAULconnections - terminals Control circuit: lugs-ring terminals (external diameter: 8 mm) Power circuit: lugs-ring terminals (external diameter: 16.5 mm)tightening torque Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5Power circuit: 6 N.m - on lugs-ring terminals hexagonal screw head 10 mm M6operating time 4...19 ms opening12...26 ms closingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 6 Mcyclesmaximum operating rate 3600 cyc/h 60 °CComplementary coil technology Without built-in suppressor modulecontrol circuit voltage limits Drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 60 °C)Operational: 0.8...1.1 Uc AC 50 Hz (at 60 °C)Operational: 0.85...1.1 Uc AC 60 Hz (at 60 °C)inrush power in VA 140 VA 60 Hz cos phi 0.75 (at 20 °C)160 VA 50 Hz cos phi 0.75 (at 20 °C)hold-in power consumption in VA 13 VA 60 Hz cos phi 0.3 (at 20 °C)15 VA 50 Hz cos phi 0.3 (at 20 °C)heat dissipation 4…5 W at 50/60 Hzauxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA for signalling circuitminimum switching voltage 17 V for signalling circuitnon-overlap time 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm for signalling circuitEnvironment IP degree of protection IP20 front face conforming to IEC 60529protective treatment TH conforming to IEC 60068-2-30pollution degree 3ambient air temperature for operation -5…60 °Cambient air temperature for storage -60…80 °Cpermissible ambient air temperature around the device -40…70 °C at Ucoperating altitude 3000 m withoutfire resistance 850 °C conforming to IEC 60695-2-1flame retardance V1 conforming to UL 94mechanical robustness Vibrations contactor open: 2 Gn, 5...300 HzVibrations contactor closed: 4 Gn, 5...300 HzShocks contactor closed: 15 Gn for 11 msShocks contactor open: 10 Gn for 11 msheight 122 mmwidth 55 mmdepth 120 mmnet weight 0.85 kgOffer Sustainability Sustainable offer status Green Premium productREACh Regulation EU RoHS Directive Compliant
EU RoHS DeclarationToxic heavy metal free YesMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages10
- English11
- Chinese5
- French6
- German5
- Italian5
- Portuguese5
- Russian5
- Spanish5
CADFormatSizeAdd to My DocumentsCAD for LC1D40A6FE7: TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 115 V AC 50/60 Hz coil (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.CAD for LC1D40A6FE7: TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 115 V AC 50/60 Hz coil (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.3P EVLK CONT 40A 18,5KW (Version 1.0)Files in documentSize zipSize 1.3 MBDate 9/24/18Files in documentCertificateFormatSizeAdd to My DocumentsInstruction sheetFormatSizeAdd to My DocumentsLC1D..A6 3-pole contactor with ring-type connection 40 to 80 A AC-3 (Version 11)DescriptionLC1D..A6 3-pole contactor with ring-type connection 40 to 80 A AC-3 - Instruction sheetSize pdfSize 5.6 MBDate 3/1/18DescriptionLC1D..A6 3-pole contactor with ring-type connection 40 to 80 A AC-3 - Instruction sheetChina RoHS declarationFormatSizeAdd to My DocumentsLC1D40A6FE7 : TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 115 V AC 50/60 Hz coilDescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 115 V AC 50/60 Hz coilSize pdfSize 195.3 KBDate 12/16/19DescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 115 V AC 50/60 Hz coilDeclaration of conformityFormatSizeAdd to My DocumentsEnd of Life InformationFormatSizeAdd to My DocumentsEU RoHS DeclarationFormatSizeAdd to My DocumentsLC1D40A6FE7 : TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 115 V AC 50/60 Hz coilDescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 115 V AC 50/60 Hz coilSize pdfSize 195.3 KBDate 12/16/19DescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 115 V AC 50/60 Hz coilProduct Environmental ProfileFormatSizeAdd to My DocumentsREACh DeclarationFormatSizeAdd to My DocumentsLC1D40A6FE7 : TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 115 V AC 50/60 Hz coilDescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 115 V AC 50/60 Hz coilSize pdfSize 195.3 KBDate 12/16/19DescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 115 V AC 50/60 Hz coil -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.