View all
TeSys D

LC1D80FE7
LC1D80FE7
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A - 115 V AC 50/60 Hz coil
Show more characteristics-
Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Contactordevice short name LC1Dcontactor application Resistive loadMotor controlutilisation category AC-1AC-3AC-4poles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage Power circuit: <= 300 V DC 25...400 HzPower circuit: <= 690 V AC[Ie] rated operational current 125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit80 A (at <60 °C) at <= 440 V AC AC-3 for power circuitmotor power kW 22 kW at 220...230 V AC 50/60 Hz (AC-3)37 kW at 380...400 V AC 50/60 Hz (AC-3)45 kW at 415...440 V AC 50/60 Hz (AC-3)55 kW at 500 V AC 50/60 Hz (AC-3)45 kW at 660...690 V AC 50/60 Hz (AC-3)45 kW at 1000 V AC 50/60 Hz (AC-3)15 kW at 400 V AC 50/60 Hz (AC-4)motor power HP (UL / CSA) 20 hp at 200/208 V AC 50/60 Hz for 3 phases motors7.5 hp at 115 V AC 50/60 Hz for 1 phase motors15 hp at 230/240 V AC 50/60 Hz for 1 phase motors25 hp at 230/240 V AC 50/60 Hz for 3 phases motors60 hp at 460/480 V AC 50/60 Hz for 3 phases motors60 hp at 575/600 V AC 50/60 Hz for 3 phases motorscontrol circuit type AC at 50/60 Hz[Uc] control circuit voltage 115 V AC 50/60 Hzauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947overvoltage category III[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit125 A (at 60 °C) for power circuitIrms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-11100 A at 440 V for power circuit conforming to IEC 60947rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947[Icw] rated short-time withstand current 640 A 40 °C - 10 s for power circuit990 A 40 °C - 1 s for power circuit135 A 40 °C - 10 min for power circuit320 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuitassociated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1200 A gG at <= 690 V coordination type 1 for power circuit160 A gG at <= 690 V coordination type 2 for power circuitaverage impedance 0.8 mOhm - Ith 125 A 50 Hz for power circuit[Ui] rated insulation voltage Power circuit: 600 V CSA certifiedPower circuit: 600 V UL certifiedPower circuit: 1000 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-1Signalling circuit: 600 V CSA certifiedSignalling circuit: 600 V UL certifiedelectrical durability 0.8 Mcycles 125 A AC-1 at Ue <= 440 V1.5 Mcycles 80 A AC-3 at Ue <= 440 Vpower dissipation per pole 5.1 W AC-312.5 W AC-1safety cover Withmounting support RailPlatestandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications DNVGOSTULLROS (Lloyds register of shipping)RINACCCBVGLCSAconnections - terminals Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable endPower circuit: connector 1 cable(s) 4…50 mm²flexible without cable endPower circuit: connector 2 cable(s) 4…25 mm²flexible without cable endPower circuit: connector 1 cable(s) 4…50 mm²flexible with cable endPower circuit: connector 2 cable(s) 4…16 mm²flexible with cable endPower circuit: connector 1 cable(s) 4…50 mm²solid without cable endPower circuit: connector 2 cable(s) 4…25 mm²solid without cable endtightening torque Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2Power circuit: 9 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mmPower circuit: 9 N.m - on connector hexagonal screw head 4 mmoperating time 20...35 ms closing6...20 ms openingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 4 Mcyclesmaximum operating rate 3600 cyc/h 60 °CComplementary coil technology Without built-in suppressor modulecontrol circuit voltage limits Operational: 0.85...1.1 Uc AC 60 Hz (at 55 °C)Drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 55 °C)Operational: 0.8...1.1 Uc AC 50 Hz (at 55 °C)inrush power in VA 245 VA 60 Hz cos phi 0.75 (at 20 °C)245 VA 50 Hz cos phi 0.75 (at 20 °C)hold-in power consumption in VA 26 VA 60 Hz cos phi 0.3 (at 20 °C)26 VA 50 Hz cos phi 0.3 (at 20 °C)heat dissipation 6…10 W at 50/60 Hzauxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA for signalling circuitminimum switching voltage 17 V for signalling circuitnon-overlap time 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm for signalling circuitEnvironment IP degree of protection IP20 front face conforming to IEC 60529protective treatment TH conforming to IEC 60068-2-30pollution degree 3ambient air temperature for operation -5…60 °Cambient air temperature for storage -60…80 °Cpermissible ambient air temperature around the device -40…70 °C at Ucoperating altitude 3000 m withoutfire resistance 850 °C conforming to IEC 60695-2-1flame retardance V1 conforming to UL 94mechanical robustness Vibrations contactor open: 2 Gn, 5...300 HzShocks contactor open: 8 Gn for 11 msVibrations contactor closed: 3 Gn, 5...300 HzShocks contactor closed: 10 Gn for 11 msheight 127 mmwidth 85 mmdepth 130 mmnet weight 1.59 kgOffer Sustainability Sustainable offer status Green Premium productREACh Regulation EU RoHS Directive Compliant
EU RoHS DeclarationToxic heavy metal free YesMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure Circularity Profile No need of specific recycling operationsWEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages18
- English16
- Chinese7
- Finnish6
- French9
- German6
- Italian6
- Portuguese6
- Russian6
- Spanish6
CatalogueFormatSizeAdd to My DocumentsTesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.Size pdfSize 111.5 MBDate 7/12/19DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.TeSys catalogue - 2019 - 2020 - chapter A2 - open, pre-cabled motor starters (Version 6.1)DescriptionFuses- contactors assemblies and circuit breaker-contactors assemblies. Pre-cabled.Size pdfSize 4.1 MBDate 5/15/19DescriptionFuses- contactors assemblies and circuit breaker-contactors assemblies. Pre-cabled.TeSys catalogue - 2019 - 2020 - chapter B8 contactors TeSys SK,K, D, SKGC, GC, GY,GF (Version 7.0)DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesSize pdfSize 12.2 MBDate 5/15/19DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesControl Panel Technical Guide - How to quickly design optimized contactor assemblies (Version 1.1)DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .Size pdfSize 15 MBDate 3/6/18DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .Catalogue TeSys 2019 - Composants pour protection et commande de moteurs (Version 7.1)DescriptionLe catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.Size pdfSize 108.2 MBDate 7/12/19DescriptionLe catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.Catalogue TeSys - 2019 - Chapitre A2 - Démarreurs-moteurs nus pré-cablés (Version 4.0)DescriptionEnsembles de démarrage moteur montés sur platine et câblés ou simplement assemblés. Ils comprennent un disjoncteur moteur + contacteur ou fusibles + contacteur. Commande 1, 2 sens de rotation ou démarrage étoile-triangle.Size pdfSize 5.7 MBDate 6/11/19DescriptionEnsembles de démarrage moteur montés sur platine et câblés ou simplement assemblés. Ils comprennent un disjoncteur moteur + contacteur ou fusibles + contacteur. Commande 1, 2 sens de rotation ou démarrage étoile-triangle.Catalogue TeSys 2019 - Chapitre B8 - Contacteurs (Version 4.0)DescriptionPrésentation des gammes de contacteurs TeSys K, D. Gamme de mini contacteurs TeSys SK. Gamme de contacteurs modulaires Tesys GC, contateurs jour/nuit modulaires teSys GY, mini contacteurs modulaires TeSys SKGC, télérupteurs modulaires TeSys GF.Size pdfSize 12.3 MBDate 6/11/19DescriptionPrésentation des gammes de contacteurs TeSys K, D. Gamme de mini contacteurs TeSys SK. Gamme de contacteurs modulaires Tesys GC, contateurs jour/nuit modulaires teSys GY, mini contacteurs modulaires TeSys SKGC, télérupteurs modulaires TeSys GF.CADFormatSizeAdd to My DocumentsCAD for LC1D80FE7: TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A - 115 V AC 50/60 Hz coil (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.CAD for LC1D80FE7: TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A - 115 V AC 50/60 Hz coil (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.CertificateFormatSizeAdd to My DocumentsInstruction sheetFormatSizeAdd to My DocumentsLC1/LC2 D40...D95 - 80 to 95 A contactors and reversing contactors (Version 12)DescriptionW90444935011411 W904449350114 W90444935 0444935 W90444Size pdfSize 1.7 MBDate 2/18/19DescriptionW90444935011411 W904449350114 W90444935 0444935 W90444Declaration of conformityFormatSizeAdd to My DocumentsEU RoHS DeclarationFormatSizeAdd to My DocumentsTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A - 115 V AC 50/60 Hz coilDescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A - 115 V AC 50/60 Hz coilSize pdfSize 195.3 KBDate 12/9/19DescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A - 115 V AC 50/60 Hz coilProduct Environmental ProfileFormatSizeAdd to My DocumentsREACh DeclarationFormatSizeAdd to My DocumentsTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A - 115 V AC 50/60 Hz coilDescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A - 115 V AC 50/60 Hz coilSize pdfSize 195.3 KBDate 12/9/19DescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A - 115 V AC 50/60 Hz coilChina RoHS declarationFormatSizeAdd to My DocumentsTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A - 115 V AC 50/60 Hz coilDescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A - 115 V AC 50/60 Hz coilSize pdfSize 195.3 KBDate 12/9/19DescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A - 115 V AC 50/60 Hz coil -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.