Welcome to the Schneider Electric corporate Website

Select your location

View all   TeSys F
Schneider Electric LC1F800 Image

LC1F800

Green premium brand logo
Schneider Electric LC1F800 Image
LC1F800
Green premium brand logo

TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 800 A with coil LX1/ LX9 - 110…400V AC 40/400Hz, LX4 - 110...400V DC, LXE - 100...250V AC 50/60Hz

Show more characteristics
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range
    TeSys
    product name
    TeSys F
    product or component type
    Contactor
    device short name
    LC1F
    contactor application
    Motor control
    Resistive load
    utilisation category
    AC-3
    AC-1
    AC-4
    poles description
    3P
    power pole contact composition
    3 NO
    [Ue] rated operational voltage
    <= 1000 V AC 50/60 Hz
    <= 460 V DC
    [Ie] rated operational current
    1000 A (at <40 °C) at <= 440 V AC AC-1
    800 A (at <55 °C) at <= 440 V AC AC-3
    motor power kW
    450 kW at 1000 V AC 50/60 Hz (AC-3)
    450 kW at 500 V AC 50/60 Hz (AC-3)
    475 kW at 660...690 V AC 50/60 Hz (AC-3)
    110 kW at 400 V AC 50/60 Hz (AC-4)
    450 kW at 380...400 V AC 50/60 Hz (AC-3)
    450 kW at 415 V AC 50/60 Hz (AC-3)
    450 kW at 440 V AC 50/60 Hz (AC-3)
    250 kW at 220...240 V AC 50/60 Hz (AC-3)
    Complementary
    [Uc] control circuit voltage
    110...400 V AC 40...400 Hz with LX1/LX9 coil
    110...400 V DC with LX4 coil
    100...250 V AC 50/60 Hz with LXE coil
    100...380 V DC with LXE coil
    [Uimp] rated impulse withstand voltage
    8 kV
    overvoltage category
    III
    [Ith] conventional free air thermal current
    1000 A (at 40 °C)
    Irms rated making capacity
    8000 A AC conforming to IEC 60947-4-1
    rated breaking capacity
    6400 A conforming to IEC 60947-4-1
    [Icw] rated short-time withstand current
    3000 A 40 °C - 3 min
    6250 A 40 °C - 10 s
    5600 A 40 °C - 30 s
    4600 A 40 °C - 1 min
    2200 A 40 °C - 10 min
    associated fuse rating
    1000 A gG at <= 440 V
    800 A aM at <= 440 V
    average impedance
    0.12 mOhm - Ith 1000 A 50 Hz
    [Ui] rated insulation voltage
    1000 V conforming to IEC 60947-4-1
    1500 V conforming to VDE 0110 group C
    power dissipation per pole
    120 W AC-1
    77 W AC-3
    control circuit voltage limits
    Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil
    Drop-out: 0.3...0.5 Uc AC 40...400 Hz with LX1/LX9 coil
    Operational: 0.85...1.1 Uc DC with LX4 coil
    Drop-out: 0.3...0.5 Uc DC with LX4 coil
    Operational: 85...275 V AC 50/60 Hz with LXE coil
    Drop-out: 0...60 V AC 50/60 Hz with LXE coil
    Operational: 85...418 V DC with LXE coil
    Drop-out: 0...45 V DC with LXE coil
    heat dissipation
    25 W
    2.2…5.5 W
    operating time
    60...80 ms closing for with LX1/LX9 coil
    160...180 ms opening for with LX1/LX9 coil
    60...80 ms closing for with LX4 coil
    40...50 ms opening for with LX4 coil
    40...80 ms closing for with LXE coil
    6...54 ms opening for with LXE coil
    mounting support
    Plate
    standards
    IEC 60947-1
    JIS C8201-4-1
    EN 60947-1
    IEC 60947-4-1
    EN 60947-4-1
    product certifications
    CB
    CSA
    LROS (Lloyds register of shipping)
    ABS
    CCC
    UL
    connections - terminals
    Power circuit: bar 2 cable(s) - busbar cross section: 60 x 5 mm
    Power circuit: bolted connection
    Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
    Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end
    Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
    Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end
    Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²
    Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²
    tightening torque
    Power circuit: 58 N.m
    Control circuit: 1.2 N.m
    mechanical durability
    5 Mcycles
    inrush power in VA
    1700 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
    1900 VA (at 20 °C)with LX4 coil
    460…730 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
    500…680 VA cos phi 0.5 (at 20 °C)with LXE coil
    hold-in power consumption in VA
    12 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
    12 VA (at 20 °C)with LX4 coil
    7…10 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
    4.0…5.5 VA cos phi 0.5 (at 20 °C)with LXE coil
    maximum operating rate
    600 cyc/h 55 °C
    compatibility code
    LC1F
    Environment
    IP degree of protection
    IP20 front face with shrouds conforming to IEC 60529
    IP20 front face with shrouds conforming to VDE 0106
    protective treatment
    TH
    ambient air temperature for operation
    -5…55 °C
    ambient air temperature for storage
    -60…80 °C
    permissible ambient air temperature around the device
    -5…55 °C
    mechanical robustness
    Vibrations contactor open: 2 Gn, 5...300 Hz
    Vibrations contactor closed: 4 Gn, 5...300 Hz
    Shocks contactor open: 6 Gn for 1/2 sine wave (11 ms)
    Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)
    height
    304 mm
    width
    309 mm
    depth
    255 mm
    net weight
    18.75 kg
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages19
    • English18
    • Chinese7
    • French10
    • German7
    • Italian7
    • Portuguese7
    • Russian7
    • Spanish7
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    Tesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)
    Description
    Ready-to-use motor starters and all components for building specific motor starters ( circuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.
    prp.document.label.format pdf
    Size 111.5 MB
    Date 7/12/19
    Description
    Ready-to-use motor starters and all components for building specific motor starters ( circuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.
    prp.document.label.format pdf
    Size 108.2 MB
    Date 7/12/19
    CAD
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format zip
    Size 685.2 KB
    Date 12/18/18
    Files in document
    prp.document.label.format zip
    Size 424.7 KB
    Date 8/4/06
    prp.document.label.format zip
    Size 154.7 KB
    Date 8/3/06
    Brochure
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format zip
    Size 825.6 MB
    Date 11/26/15
    Certificate
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 478.3 KB
    Date 7/17/15
    prp.document.label.format pdf
    Size 1.1 MB
    Date 4/17/17
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 4.5 MB
    Date 4/1/19
    prp.document.label.format pdf
    Size 6 MB
    Date 1/2/19
    prp.document.label.format pdf
    Size 6.5 MB
    Date 2/2/15
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    LC1F800 : TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 800 A with coil LX1/ LX9 - 110…400V AC 40/400Hz, LX4 - 110...400V DC, LXE - 100...250V AC 50/60Hz
    Description
    TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 800 A with coil LX1/ LX9 - 110…400V AC 40/400Hz, LX4 - 110...400V DC, LXE - 100...250V AC 50/60Hz
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/31/20
    Description
    TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 800 A with coil LX1/ LX9 - 110…400V AC 40/400Hz, LX4 - 110...400V DC, LXE - 100...250V AC 50/60Hz
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 301.8 KB
    Date 7/4/19
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 391.6 KB
    Date 12/18/18
    TeSys LC1 F330-1250 - EoLi (Version 1.0)
    Description
    TeSys LC1 F330-1250 - EoLi
    prp.document.label.format pdf
    Size 200.1 KB
    Date 7/1/15
    Description
    TeSys LC1 F330-1250 - EoLi
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    LC1F800 : TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 800 A with coil LX1/ LX9 - 110…400V AC 40/400Hz, LX4 - 110...400V DC, LXE - 100...250V AC 50/60Hz
    Description
    TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 800 A with coil LX1/ LX9 - 110…400V AC 40/400Hz, LX4 - 110...400V DC, LXE - 100...250V AC 50/60Hz
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/31/20
    Description
    TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 800 A with coil LX1/ LX9 - 110…400V AC 40/400Hz, LX4 - 110...400V DC, LXE - 100...250V AC 50/60Hz
    Presentation
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pptx
    Size 5.4 MB
    Date 11/25/15
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    TeSys LC1F330-1250 - PEP (Version 1.0)
    Description
    TeSys LC1F330-1250 - PEP
    prp.document.label.format pdf
    Size 202.6 KB
    Date 7/1/15
    Description
    TeSys LC1F330-1250 - PEP
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    LC1F800 : TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 800 A with coil LX1/ LX9 - 110…400V AC 40/400Hz, LX4 - 110...400V DC, LXE - 100...250V AC 50/60Hz
    Description
    TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 800 A with coil LX1/ LX9 - 110…400V AC 40/400Hz, LX4 - 110...400V DC, LXE - 100...250V AC 50/60Hz
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/31/20
    Description
    TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 800 A with coil LX1/ LX9 - 110…400V AC 40/400Hz, LX4 - 110...400V DC, LXE - 100...250V AC 50/60Hz
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.