View all
TeSys K

LC1K06015FE7
LC1K06015FE7
TeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 115 V AC coil
Show more characteristics
has not been replaced. Please contact your customer care center for more information.
-
Characteristics
Main range TeSysproduct or component type Contactorproduct name TeSys Kdevice short name LC1Kdevice application Controlcontactor application Motor controlComplementary utilisation category AC-3AC-4poles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage Power circuit: 690 V AC 50/60 HzSignalling circuit: <= 690 V AC 50/60 Hz[Ie] rated operational current 6 A at <= 440 V AC AC-3 for power circuitcontrol circuit type AC at 50/60 Hz[Uc] control circuit voltage 115 V AC 50/60 Hzmotor power kW 1.5 kW at 220...230 V AC 50/60 Hz2.2 kW at 380...415 V AC 50/60 Hz3 kW at 440 V AC 50/60 Hz3 kW at 480 V AC 50/60 Hz3 kW at 500...600 V AC 50/60 Hz3 kW at 660...690 V AC 50/60 Hzauxiliary contact composition 1 NC[Uimp] rated impulse withstand voltage 8 kVovervoltage category III[Ith] conventional free air thermal current 20 A (at 50 °C) for power circuit10 A (at 50 °C) for signalling circuitIrms rated making capacity 110 A AC for power circuit conforming to NF C 63-110110 A AC for power circuit conforming to IEC 60947110 A AC for signalling circuit conforming to IEC 60947rated breaking capacity 110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 60947110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947[Icw] rated short-time withstand current 90 A 50 °C - 1 s for power circuit85 A 50 °C - 5 s for power circuit80 A 50 °C - 10 s for power circuit60 A 50 °C - 30 s for power circuit45 A 50 °C - 1 min for power circuit40 A 50 °C - 3 min for power circuit20 A 50 °C - >= 15 min for power circuit80 A - 1 s for signalling circuit90 A - 500 ms for signalling circuit110 A - 100 ms for signalling circuitassociated fuse rating 25 A gG at <= 440 V for power circuit25 A aM for power circuit10 A gG for signalling circuit conforming to IEC 6094710 A gG for signalling circuit conforming to VDE 0660average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit[Ui] rated insulation voltage Power circuit: 600 V conforming to UL 508Power circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-5-1Signalling circuit: 600 V conforming to UL 508Power circuit: 600 V conforming to CSA C22.2 No 14Signalling circuit: 600 V conforming to CSA C22.2 No 14insulation resistance > 10 MOhm for signalling circuitinrush power in VA 30 VA (at 20 °C)hold-in power consumption in VA 4.5 VA (at 20 °C)heat dissipation 1.3 Wcontrol circuit voltage limits Operational: 0.8...1.15 Uc (at <50 °C)Drop-out: 0.2...0.75 Uc (at <50 °C)connections - terminals Solder pins - busbar cross section: 1.5 x 0.9 mmmaximum operating rate 3600 cyc/hauxiliary contacts type type instantaneous 1 NCsignalling circuit frequency <= 400 Hzminimum switching current 5 mA for signalling circuitminimum switching voltage 17 V for signalling circuitmounting support Printed circuit boardsoperating time 10...20 ms coil de-energisation and NO opening10...20 ms coil energisation and NO closingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1non overlap distance 0.5 mmmechanical durability 10 Mcycleselectrical durability 1.3 Mcycles 6 A AC-3 at Ue <= 440 Vmechanical robustness Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6height 58 mmwidth 45 mmdepth 57 mmnet weight 0.18 kgEnvironment standards BS 5424IEC 60947NF C 63-110VDE 0660product certifications ULCSAIP degree of protection IP2x conforming to VDE 0106protective treatment TC conforming to IEC 60068TC conforming to DIN 50016ambient air temperature for storage -50…80 °Coperating altitude 2000 m withoutflame retardance V1 conforming to UL 94Requirement 2 conforming to NF F 16-101Requirement 2 conforming to NF F 16-102Contractual warranty Warranty 18 months -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.