View all
TeSys D

LC2D50AY7
LC2D50AY7
TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A - 690 V AC coil
Show more characteristics-
Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Reversing contactordevice short name LC2Dcontactor application Motor controlResistive loadutilisation category AC-3AC-1device presentation Preassembled with reversing power busbarpoles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 HzPower circuit: <= 300 V DC[Ie] rated operational current 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit80 A (at <60 °C) at <= 440 V AC AC-1 for power circuitmotor power kW 15 kW at 220...230 V AC 50 Hz22 kW at 380...400 V AC 50 Hz30 kW at 500 V AC 50 Hz33 kW at 660...690 V AC 50 Hz25 kW at 415 V AC 50 Hz30 kW at 440 V AC 50 Hzmotor power HP (UL / CSA) 3 hp at 115 V AC 60 Hz for 1 phase motors7.5 hp at 230/240 V AC 60 Hz for 1 phase motors15 hp at 200/208 V AC 60 Hz for 3 phases motors15 hp at 230/240 V AC 60 Hz for 3 phases motors40 hp at 460/480 V AC 60 Hz for 3 phases motors40 hp at 575/600 V AC 60 Hz for 3 phases motorscontrol circuit type AC at 50/60 Hz[Uc] control circuit voltage 690 V AC 50/60 Hzauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947overvoltage category III[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit80 A (at 60 °C) for power circuitIrms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1900 A at 440 V for power circuit conforming to IEC 60947rated breaking capacity 900 A at 440 V for power circuit conforming to IEC 60947[Icw] rated short-time withstand current 400 A 40 °C - 10 s for power circuit810 A 40 °C - 1 s for power circuit84 A 40 °C - 10 min for power circuit208 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuitassociated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1100 A gG at <= 690 V coordination type 1 for power circuit100 A gG at <= 690 V coordination type 2 for power circuitaverage impedance 1.5 mOhm - Ith 80 A 50 Hz for power circuit[Ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1Power circuit: 600 V CSA certifiedPower circuit: 600 V UL certifiedSignalling circuit: 690 V conforming to IEC 60947-1Signalling circuit: 600 V CSA certifiedSignalling circuit: 600 V UL certifiedelectrical durability 1.45 Mcycles 50 A AC-3 at Ue <= 440 V1.1 Mcycles 80 A AC-1 at Ue <= 440 Vpower dissipation per pole 3.7 W AC-39.6 W AC-1safety cover Withinterlocking type Mechanicalmounting support RailPlatestandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications GOSTULCSACCCconnections - terminals Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable endPower circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²flexible without cable endPower circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²flexible without cable endPower circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²flexible with cable endPower circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²flexible with cable endPower circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²solid without cable endPower circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²solid without cable endtightening torque Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25…35 mm² hexagonal screw head 4 mmPower circuit: 5 N.m - on EverLink BTR screw connectors - cable 1…25 mm² hexagonal screw head 4 mmoperating time 4...19 ms opening12...26 ms closingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 6 Mcyclesmaximum operating rate 3600 cyc/h 60 °CComplementary coil technology Without built-in suppressor modulecontrol circuit voltage limits Drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 60 °C)Operational: 0.8...1.1 Uc AC 50 Hz (at 60 °C)Operational: 0.85...1.1 Uc AC 60 Hz (at 60 °C)inrush power in VA 140 VA 60 Hz cos phi 0.75 (at 20 °C)160 VA 50 Hz cos phi 0.75 (at 20 °C)hold-in power consumption in VA 13 VA 60 Hz cos phi 0.3 (at 20 °C)15 VA 50 Hz cos phi 0.3 (at 20 °C)heat dissipation 4…5 W at 50/60 Hzauxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA for signalling circuitminimum switching voltage 17 V for signalling circuitnon-overlap time 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm for signalling circuitEnvironment IP degree of protection IP20 front face conforming to IEC 60529protective treatment TH conforming to IEC 60068-2-30pollution degree 3ambient air temperature for operation -5…60 °Cambient air temperature for storage -60…80 °Cpermissible ambient air temperature around the device -40…70 °C at Ucoperating altitude 3000 m withoutfire resistance 850 °C conforming to IEC 60695-2-1flame retardance V1 conforming to UL 94mechanical robustness Vibrations contactor open: 2 Gn, 5...300 HzVibrations contactor closed: 4 Gn, 5...300 HzShocks contactor open: 10 Gn for 11 msShocks contactor closed: 15 Gn for 11 msheight 122 mmwidth 119 mmdepth 120 mmnet weight 1.88 kgOffer Sustainability EU RoHS Directive Compliant
EU RoHS DeclarationToxic heavy metal free YesMercury free YesRoHS exemption information China RoHS Regulation Circularity Profile No need of specific recycling operationsContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages4
- English5
- Chinese3
- French3
- German3
- Italian3
- Portuguese3
- Russian3
- Spanish3
CADFormatSizeAdd to My Documents3P EVLK REVERS CONT 40A (Version 1.0)Files in documentSize zipSize 1.2 MBDate 12/18/17Files in documentInstruction sheetFormatSizeAdd to My DocumentsLC1D..A, LC1D..A3, LC2D..A, LC2D..A3 Everlink 3-pole contactors and reversing contactors 40 to 80 A AC-3 (Version 14)DescriptionLC1D..A, LC1D..A3, LC2D..A, LC2D..A3 Everlink 3-pole contactors and reversing contactors 40 to 80 A AC-3 - Instruction SheetSize pdfSize 7.4 MBDate 9/1/17DescriptionLC1D..A, LC1D..A3, LC2D..A, LC2D..A3 Everlink 3-pole contactors and reversing contactors 40 to 80 A AC-3 - Instruction SheetChina RoHS declarationFormatSizeAdd to My DocumentsLC2D50AY7 : TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A - 690 V AC coilDescriptionTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A - 690 V AC coilSize pdfSize 195.3 KBDate 12/15/19DescriptionTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A - 690 V AC coilEU RoHS DeclarationFormatSizeAdd to My DocumentsLC2D50AY7 : TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A - 690 V AC coilDescriptionTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A - 690 V AC coilSize pdfSize 195.3 KBDate 12/15/19DescriptionTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A - 690 V AC coil -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.