Welcome to the Schneider Electric corporate Website

Select your location

View all TeSys LF
Schneider Electric LF3MP00D Image
Discontinued

LF3MP00D

Schneider Electric LF3MP00D Image
Discontinued
LF3MP00D

TeSys LF - enclosed DOL starter - 0.16...0.25 A

Show more characteristics
  has not been replaced. Please contact your customer care center for more information.
The maximum number of products that can be compared is 4

  • Main
    range
    TeSys
    product name
    TeSys LF
    product or component type
    Enclosed DOL starter
    device application
    AS interface
    device composition
    Circuit-breaker ordered separately
    Contactor
    AS interface module
    utilisation category
    AC-3
    network type
    AC
    [Uc] control circuit voltage
    24 V AC 50/60 Hz
    thermal protection adjustment range
    0.16…0.25 A
    control type
    Rotary handle for protection control - OFF - Trip - ON
    Complementary
    network frequency
    50/60 Hz
    [Ue] rated operational voltage
    Power circuit: 415 V AC 50/60 Hz
    Output control relay: 250 V AC 50/60 Hz
    Output control relay: 30 V DC
    [Uimp] rated impulse withstand voltage
    6 kV for power circuit conforming to IEC 60947-1
    2.5 kV for 24 V conforming to IEC 60947-1
    2.5 kV for sensor conforming to IEC 60947-1
    2.5 kV for AS-Interface conforming to IEC 60947-1
    insulation resistance
    > 1000 mOhm for output and communication
    insulation
    1500 V between output and ground
    1500 V between output and internal logic
    between input and communication
    [Ui] rated insulation voltage
    415 V AC 50/60 Hz conforming to IEC 60947
    [Ithe] conventional enclosed thermal current
    5 A for output control relay at 40 °C
    protection type
    Inductive overvoltage
    Phase failure
    breaking capacity
    100 kA at 230/240 V conforming to IEC 60947-2
    100 kA at 400/415 V conforming to IEC 60947-2
    mechanical durability
    0.1 Mcycles for circuit breaker
    30 Mcycles for contactor
    electrical durability
    Circuit breaker: 0.1 Mcycles
    Contactor: 0.8 Mcycles - AC-3 - 8.5 A
    Relay: 0.1 Mcycles - 24 V, operating rate <6 cyc/mn - AC-12 - 5 A
    Relay: 1 Mcycles - 24 V, operating rate <15 cyc/mn - AC-12 - 1 A
    Relay: 0.5 Mcycles - 24 V, operating rate <15 cyc/mn - AC-14 - 1 A
    Relay: 1 Mcycles - 24 V, operating rate <15 cyc/mn - AC-14 - 0.5 A
    Relay: 5 Mcycles - 24 V, operating rate <30 cyc/mn - AC-14 - 0.25 A
    Relay: 0.1 Mcycles - 24 V, operating rate <6 cyc/mn - DC-12 - 5 A
    Relay: 0.2 Mcycles - 24 V, operating rate <6 cyc/mn - DC-12 - 2 A
    Relay: 0.5 Mcycles - 24 V, operating rate <15 cyc/mn - DC-3 - 1 A
    Relay: 1 Mcycles - 24 V, operating rate <30 cyc/mn - DC-3 - 0.25 A
    current consumption
    20 mA for communication bus during operation
    60 mA for communication bus sensor
    0 mA at 24 V for supply circuit de-energisation
    30 mA at 24 V for supply circuit maintained mode
    110 mA at 24 V for supply circuit inrush
    local signalling
    Product status: 3 LEDs
    Input/output status: LED
    number of inputs
    2 M12
    nominal input value
    19...30 V 50 mA - DC
    input description
    Status D0: forward stop - bit value 0
    Status D1: reverse stop - bit value 0
    Status D2: disable relay - bit value 0
    Status D3: unused - bit value 0
    Status D0: forward start - bit value 1
    Status D1: reverse start - bit value 1
    Status D2: enable relay - bit value 1
    Status D3: unused - bit value 1
    input type
    Resistive
    sensor compatibility
    2 or 3-wire PNP
    output description
    Command D0: not ready - bit value 0
    Command D1: stopped - bit value 0
    Command D2: sensor 1 missing - bit value 0
    Command D3: sensor 2 missing - bit value 0
    Command D0: ready - bit value 1
    Command D1: started - bit value 1
    Command D2: sensor 1 present - bit value 1
    Command D3: sensor 2 present - bit value 1
    response time
    <= 10 ms closing for output control relay
    <= 15 ms opening for output control relay
    contacts type and composition
    1 C/O
    AS-interface profile
    7DFF - standard
    cable gland type
    Supply circuit: Pg 16 - 10…15 mm
    Power circuit: Pg 16 - 10…15 mm
    Output control relay: Pg 13 - 10…15 mm
    Output control relay: Pg 16 - 10…15 mm
    connections - terminals
    Supply circuit: screw clamp terminals, 1 x 1.5...2 x 6 mm²rigid
    Supply circuit: screw clamp terminals, 1 x 1.5...2 x 6 mm²flexible without cable end
    Supply circuit: screw clamp terminals, 1 x 1.5...2 x 4 mm²flexible with cable end
    Power circuit: screw clamp terminals, 1 x 1.5...2 x 4 mm²rigid
    Power circuit: screw clamp terminals, 1 x 1.5...2 x 4 mm²flexible without cable end
    Power circuit: screw clamp terminals, 1 x 1.5...1 x 2.5 mm²flexible with cable end
    Output control relay: screw terminals, 1 x 0.5...1 x 1.5 mm²rigid
    Output control relay: screw terminals, 1 x 0.5...1 x 1.5 mm²flexible without cable end
    Output control relay: screw terminals, 1 x 0.5...1 x 1.5 mm²flexible with cable end
    tightening torque
    Supply circuit: 1.7 N.m - with screwdriver flat Ø 5.5 mm
    Power circuit: 0.8 N.m - with screwdriver flat Ø 5.5 mm
    Output control relay: 0.7 N.m - with screwdriver flat Ø 3.5 mm
    width
    219 mm
    height
    245 mm
    depth
    179 mm
    net weight
    1.02 kg
    Environment
    electromagnetic compatibility
    Electrostatic discharge - test level: 8 kV level 3 (in air) conforming to EN/IEC 61000-4-2
    Electrostatic discharge - test level: 4 kV level 2 (in indirect mode) conforming to EN/IEC 61000-4-2
    Surge immunity test - test level: 4 kV level 4 (power, line to ground) conforming to IEC 61000-4-5
    Surge immunity test - test level: 2 kV level 4 (power, line to line) conforming to EN/IEC 61000-4-5
    Surge immunity test - test level: 2 kV level 2 (control circuit, line to ground) conforming to IEC 61000-4-5
    Surge immunity test - test level: 500 V level 2 (control circuit, line to line) conforming to EN/IEC 61000-4-5
    Electrical fast transient/burst immunity test - test level: 2 kV level 3 conforming to EN/IEC 61000-4-4
    Conducted RF disturbances - test level: 10 V/m conforming to IEC 61000-4-6
    Conducted RF disturbances - test level: 10 V/m conforming to ENV 50141
    Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m conforming to IEC 61000-4-3
    Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m conforming to ENV 50204
    Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m conforming to ENV 50140
    Disturbing field emission class B conforming to ENV 55011
    Disturbing field emission class B conforming to CISPR 11
    mechanical robustness
    Shocks contactor open - 10 Gn conforming to IEC 60068-2-27
    Shocks contactor closed - 15 gn conforming to IEC 60068-2-27
    Vibrations contactor open - 2 Gn conforming to IEC 60068-2-6
    Vibrations contactor closed - 4 gn conforming to IEC 60068-2-6
    IP degree of protection
    IP54 conforming to IEC 60529
    protective treatment
    TC
    fire resistance
    960 °C conforming to IEC 60695-2-1
    operating altitude
    2000 m
    standards
    IEC 60947-1
    IEC 60439-1
    EN 60439-1
    EN 60947-1
    EN 60204-1
    IEC 60204-1
    material
    Steel - white: RAL 9001
    ambient air temperature for operation
    -5…40 °C conforming to IEC 61439-1
    ambient air temperature for storage
    -40…80 °C conforming to IEC 61439-1
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages2
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    GV2AP.. Fixing kit for door interlock mechanism for GV2 P/L (Version 07)
    Description
    GV2-AP.. Fixing kit for door interlock mechanism for GV2 P/L
    Size pdf
    Size 501.8 KB
    Date 4/1/16
    Description
    GV2-AP.. Fixing kit for door interlock mechanism for GV2 P/L
    LF3-LF4 Enclosed starter for AS-Interface - Instruction sheet (Version 02)
    Description
    LF3-LF4 Enclosed starter for AS-Interface - Instruction sheet
    Size pdf
    Size 5.1 MB
    Date 8/3/15
    Description
    LF3-LF4 Enclosed starter for AS-Interface - Instruction sheet
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /