TeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 24 V DC coil
Show more characteristics-
Characteristics
Main range of product TeSys Krange TeSysproduct or component type Contactordevice short name LP1Kcontactor application Motor controlutilisation category AC-3AC-4poles description 3Ppole contact composition 3 NO[Ie] rated operational current 6 A at <= 440 V AC AC-3 for power circuitauxiliary contact composition 1 NCComplementary auxiliary contacts type type instantaneous 1 NCcontrol circuit voltage limits Operational: 0.8...1.15 Uc (at <50 °C)Drop-out: 0.1...0.75 Uc (at <50 °C)[Ui] rated insulation voltage Power circuit: 600 V conforming to UL 508Power circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-5-1Signalling circuit: 600 V conforming to UL 508Power circuit: 600 V conforming to CSA C22.2 No 14Signalling circuit: 600 V conforming to CSA C22.2 No 14[Uimp] rated impulse withstand voltage 8 kVovervoltage category IIImounting support RailPlateflame retardance V1 conforming to UL 94Requirement 2 conforming to NF F 16-101Requirement 2 conforming to NF F 16-102[Ue] rated operational voltage Power circuit: 690 V AC 50/60 HzSignalling circuit: <= 690 V AC 50/60 Hz[Ith] conventional free air thermal current 20 A (at 50 °C) for power circuit10 A (at 50 °C) for signalling circuitIrms rated making capacity 110 A AC for power circuit conforming to NF C 63-110110 A AC for power circuit conforming to IEC 60947110 A AC for signalling circuit conforming to IEC 60947rated breaking capacity 110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 60947110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947associated fuse rating 25 A gG at <= 440 V for power circuit25 A aM for power circuit10 A gG for signalling circuit conforming to IEC 6094710 A gG for signalling circuit conforming to VDE 0660average impedance 3 mOhm - Ith 20 A 50 Hz for power circuitinrush power in W 3 W (at 20 °C)hold-in power consumption in W 3 W at 20 °Coperating time 30...40 ms coil energisation and NO closing10 ms coil de-energisation and NO openingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 10 Mcyclesmaximum operating rate 3600 cyc/hminimum switching current 5 mA for signalling circuitminimum switching voltage 17 V for signalling circuitinsulation resistance > 10 MOhm for signalling circuitdepth 57 mmnet weight 0.225 kgEnvironment product certifications ULCSAambient air temperature for storage -50…80 °Coperating altitude 2000 m withoutOffer Sustainability Sustainable offer status Green Premium productREACh Regulation EU RoHS Directive Compliant
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation China RoHS declaration
Product out of China RoHS scope. Substance declaration for your informationEnvironmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages11
- English11
- French5
CADFormatSizeAdd to My DocumentsCAD for LP1K06013BD: TeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 24 V DC coil (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.CAD for LP1K06013BD: TeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 24 V DC coil (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.CONTACTOR SPRING (Version 1.0)Files in documentSize zipSize 1.4 MBDate 12/18/17Files in documentCertificateFormatSizeAdd to My DocumentsChina RoHS declarationFormatSizeAdd to My DocumentsTeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 24 V DC coilDescriptionTeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 24 V DC coilSize pdfSize 195.3 KBDate 12/13/19DescriptionTeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 24 V DC coilDeclaration of conformityFormatSizeAdd to My DocumentsEnd of Life InformationFormatSizeAdd to My DocumentsEU RoHS DeclarationFormatSizeAdd to My DocumentsTeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 24 V DC coilDescriptionTeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 24 V DC coilSize pdfSize 195.3 KBDate 12/13/19DescriptionTeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 24 V DC coilProduct Environmental ProfileFormatSizeAdd to My DocumentsREACh DeclarationFormatSizeAdd to My DocumentsTeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 24 V DC coilDescriptionTeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 24 V DC coilSize pdfSize 195.3 KBDate 12/13/19DescriptionTeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 24 V DC coil -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.