Welcome to the Schneider Electric corporate Website

Select your location

View all   TeSys LRD
Schneider Electric LRD3133 Image

LRD3133

Schneider Electric LRD3133 Image
LRD3133

TeSys LRD thermal overload relays - 9...13 A - class 10A

Show more characteristics
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range
    TeSys
    product name
    TeSys LRD
    product or component type
    Differential thermal overload relay
    device short name
    LRD
    relay application
    Motor protection
    product compatibility
    LC1D65A
    LC1D40A
    LC1D50A
    network type
    DC
    AC
    thermal protection adjustment range
    9…13 A
    [Ui] rated insulation voltage
    Power circuit: 600 V conforming to CSA
    Power circuit: 600 V conforming to UL
    Power circuit: 690 V conforming to IEC 60947-4-1
    Complementary
    network frequency
    0...400 Hz
    mounting support
    Plate, with specific accessories
    Rail, with specific accessories
    Under contactor
    tripping threshold
    1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
    [Ith] conventional free air thermal current
    5 A for signalling circuit
    permissible current
    0.95 A at 380 V AC-15 for signalling circuit
    0.06 A at 440 V DC-13 for signalling circuit
    [Ue] rated operational voltage
    690 V AC 0...400 Hz
    [Uimp] rated impulse withstand voltage
    6 kV
    phase failure sensitivity
    Tripping current 130 % of Ir on two phase, the last one at 0
    control type
    Red push-button: stop
    Blue push-button: reset
    temperature compensation
    -20…60 °C
    connections - terminals
    Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm² flexible without cable end
    Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm² flexible with cable end
    Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm² solid without cable end
    Control circuit: spring terminals 1 cable(s) 1…2.5 mm² solid without cable end
    Control circuit: spring terminals 1 cable(s) 1…2.5 mm² flexible without cable end
    tightening torque
    Power circuit: 5 N.m - on EverLink BTR screw connectors
    height
    70 mm
    width
    55 mm
    depth
    123 mm
    net weight
    0.375 kg
    Environment
    protective treatment
    TH conforming to IEC 60068
    IP degree of protection
    IP20 conforming to IEC 60529
    ambient air temperature for operation
    -20…60 °C without derating conforming to IEC 60947-4-1
    ambient air temperature for storage
    -60…70 °C
    flame retardance
    V1 conforming to UL 94
    mechanical robustness
    Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7
    Vibrations: 4 gn conforming to IEC 60068-2-6
    dielectric strength
    6 kV at 50 Hz conforming to IEC 60255-5
    standards
    ATEX D 94/9/CE
    EN 60947-5-1
    UL 508
    IEC 60947-4-1
    IEC 60947-5-1
    EN 60947-4-1
    CSA C22.2 No 14
    product certifications
    RINA
    GOST
    UL
    CSA
    BV
    CCC
    ATEX INERIS
    DNV
    LROS (Lloyds register of shipping)
    GL
    Offer Sustainability
    REACh free of SVHC
    Yes
    EU RoHS Directive
    Toxic heavy metal free
    Yes
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages11
    • English11
    • Chinese4
    • French6
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    Tesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)
    Description
    Ready-to-use motor starters and all components for building specific motor starters ( circuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.
    prp.document.label.format pdf
    Size 111.5 MB
    Date 7/12/19
    Description
    Ready-to-use motor starters and all components for building specific motor starters ( circuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.
    User guide
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 1.3 MB
    Date 4/2/18
    CAD
    Format
    Size
    Date
    Add to My Documents
    TeSys LRD thermal overload relays (Version 1.0)
    Files in document
    stp
    304.2 KB
    pdf
    231.5 KB
    prp.document.label.format zip
    Size 535.7 KB
    Date 2/15/18
    Files in document
    stp
    304.2 KB
    pdf
    231.5 KB
    Certificate
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 421 KB
    Date 4/10/18
    prp.document.label.format pdf
    Size 1.7 MB
    Date 7/17/17
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    LRD3.., LRD3..3, LRD3..L, LRD3..L3, LR3D3.., LR3D3..3 - Everlink 3-pole thermal overload relays 18.5 to 37 kW (Version 04)
    Description
    LRD3.., LRD3..3, LRD3..L, LRD3..L3, LR3D3.., LR3D3..3 - Everlink 3-pole thermal overload relays 18.5 to 37 kW - Instruction sheet
    prp.document.label.format pdf
    Size 3.3 MB
    Date 1/1/18
    Description
    LRD3.., LRD3..3, LRD3..L, LRD3..L3, LR3D3.., LR3D3..3 - Everlink 3-pole thermal overload relays 18.5 to 37 kW - Instruction sheet
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    LRD3133 : TeSys LRD thermal overload relays - 9...13 A - class 10A
    Description
    TeSys LRD thermal overload relays - 9...13 A - class 10A
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/27/20
    Description
    TeSys LRD thermal overload relays - 9...13 A - class 10A
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 311.5 KB
    Date 7/1/19
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    LRD3133 : TeSys LRD thermal overload relays - 9...13 A - class 10A
    Description
    TeSys LRD thermal overload relays - 9...13 A - class 10A
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/27/20
    Description
    TeSys LRD thermal overload relays - 9...13 A - class 10A
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    LRD3133 : TeSys LRD thermal overload relays - 9...13 A - class 10A
    Description
    TeSys LRD thermal overload relays - 9...13 A - class 10A
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/27/20
    Description
    TeSys LRD thermal overload relays - 9...13 A - class 10A
  • Technical FAQs

    No results found.