TeSys LRD thermal overload relays - 55...70 A - class 10A

Show more characteristics
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range
    TeSys
    product name
    TeSys LRD
    product or component type
    Differential thermal overload relay
    device short name
    LRD
    relay application
    Motor protection
    product compatibility
    LC1D95
    LC1D80
    network type
    DC
    AC
    thermal protection adjustment range
    55…70 A
    [Ui] rated insulation voltage
    Power circuit: 1000 V conforming to IEC 60947-4-1
    Power circuit: 600 V conforming to CSA
    Power circuit: 600 V conforming to UL
    Complementary
    network frequency
    0...400 Hz
    mounting support
    Plate, with specific accessories
    Rail, with specific accessories
    Under contactor
    tripping threshold
    1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
    [Ith] conventional free air thermal current
    5 A for signalling circuit
    permissible current
    0.72 A at 500 V AC-15 for signalling circuit
    0.06 A at 440 V DC-13 for signalling circuit
    [Ue] rated operational voltage
    690 V AC 0...400 Hz
    [Uimp] rated impulse withstand voltage
    6 kV
    phase failure sensitivity
    Tripping current 130 % of Ir on two phase, the last one at 0
    control type
    Red push-button: stop
    Blue push-button: reset
    temperature compensation
    -20…60 °C
    connection pitch
    17.5 mm
    connections - terminals
    Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end
    Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end
    Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid without cable end
    Power circuit: lugs-ring terminals
    tightening torque
    Control circuit: 1.7 N.m - on screw clamp terminals
    Power circuit: 11.3 N.m - on lugs-ring terminals M10
    height
    123 mm
    width
    75 mm
    depth
    121 mm
    net weight
    0.51 kg
    Environment
    protective treatment
    TH conforming to IEC 60068
    IP degree of protection
    IP20 conforming to IEC 60529
    ambient air temperature for operation
    -20…60 °C without derating conforming to IEC 60947-4-1
    ambient air temperature for storage
    -60…70 °C
    flame retardance
    V1 conforming to UL 94
    mechanical robustness
    Vibrations: 6 Gn conforming to IEC 60068-2-6
    Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7
    dielectric strength
    6 kV at 50 Hz conforming to IEC 60255-5
    standards
    IEC 60947-4-1
    CSA C22.2 No 14
    ATEX D 94/9/CE
    UL 508
    IEC 60947-5-1
    EN 60947-5-1
    EN 60947-4-1
    product certifications
    RINA
    CCC
    ATEX INERIS
    UL
    LROS (Lloyds register of shipping)
    GL
    BV
    CSA
    DNV
    GOST
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh free of SVHC
    Yes
    EU RoHS Directive
    Toxic heavy metal free
    Yes
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
     Pro-active China RoHS declaration (out of China RoHS legal scope)
    Environmental Disclosure
    Circularity Profile
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages12
    • English12
    • Chinese5
    • French6
    User guide
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 849.8 KB
    Date 1/2/14
    CAD
    Format
    Size
    Date
    Add to My Documents
    Certificate
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 1.3 MB
    Date 5/22/18
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 605.9 KB
    Date 6/1/16
    prp.document.label.format pdf
    Size 1.7 MB
    Date 12/3/12
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    LRD3361A66 : TeSys LRD thermal overload relays - 55...70 A - class 10A
    Description
    TeSys LRD thermal overload relays - 55...70 A - class 10A
    prp.document.label.format pdf
    Size 195.3 KB
    Date 6/6/20
    Description
    TeSys LRD thermal overload relays - 55...70 A - class 10A
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 313.6 KB
    Date 7/1/19
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 824.4 KB
    Date 11/27/15
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    LRD3361A66 : TeSys LRD thermal overload relays - 55...70 A - class 10A
    Description
    TeSys LRD thermal overload relays - 55...70 A - class 10A
    prp.document.label.format pdf
    Size 195.3 KB
    Date 6/6/20
    Description
    TeSys LRD thermal overload relays - 55...70 A - class 10A
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 187.5 KB
    Date 11/30/15
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    LRD3361A66 : TeSys LRD thermal overload relays - 55...70 A - class 10A
    Description
    TeSys LRD thermal overload relays - 55...70 A - class 10A
    prp.document.label.format pdf
    Size 195.3 KB
    Date 6/6/20
    Description
    TeSys LRD thermal overload relays - 55...70 A - class 10A
  • Technical FAQs