Welcome to the Schneider Electric corporate Website

Select your location

View all   MasterPact MTZ
Schneider Electric LV847288 Image

LV847288

Green premium brand logo
Schneider Electric LV847288 Image
LV847288
Green premium brand logo

Micrologic 6.0 X control unit, for Masterpact MTZ circuit breakers, fixed, LSIG protections

Show more characteristics
The maximum number of products that can be compared is 4

  • Main
    range
    Masterpact
    device short name
    Micrologic 6.0 X
    product or component type
    Control unit
    device application
    Equipment protection, monitoring and control
    range compatibility
    Masterpact MTZ1 circuit breaker
    Masterpact MTZ2 circuit breaker
    Masterpact MTZ3 circuit breaker
    Poles
    3P
    4P
    Protected poles
    3P 3d
    4P 3d
    4P 4d
    4P 3d + OSN
    4P 3d + N/2
    circuit breaker application
    Distribution IEC standard
    network type
    AC
    trip unit technology
    Electronic
    trip unit protection functions
    LSIG
    protection type
    Overload protection (long time) conforming to ANSI 49
    Instantaneous short-circuit protection conforming to ANSI 50
    Short time short-circuit protection conforming to ANSI 51
    Earth fault conforming to ANSI 51N
    trip unit rating
    1000 A
    5000 A
    2500 A
    3200 A
    630 A
    1250 A
    400 A
    4000 A
    800 A
    6300 A
    1600 A
    2000 A
    Complementary
    network frequency
    50/60 Hz
    mounting mode
    Fixed
    [Ir] long time pick-up adjustment range
    0.4...1 x In adjustable in step of 1 A
    [tr] long-time delay adjustment range
    12.5…600 s at 1.5 x Ir
    0.5…24 s at 6 x Ir
    0.7…16.6 s at 7.2 x Ir
    long time delay adjustment type
    Adjustable in step of 0.5 s
    [Isd] short-time pick-up adjustment range
    1.5...10 x Ir adjustable in step of 0.5 x Ir with embedded HMI
    1.5...10 x Ir adjustable in step of 0.1 x Ir with Ecoreach software or Masterpact MTZ mobile app
    [tsd] short-time delay adjustment range
    0.1…0.4 s I²t=on
    0…0.4 s I²t=off
    short-time delay adjustment type
    Adjustable
    [Ii] instantaneous pick-up adjustment range
    2...15 x In adjustable in step of 0.5 x In with embedded HMI
    2...15 x In adjustable in step of 0.1 x In with Ecoreach software or Masterpact MTZ mobile app
    Ii enable on/off
    [li mode] instantaneous delay adjustment range
    0 ms in fast
    20 ms in standard
    instantaneous pick-up adjustment type Ii
    Adjustable
    [Ig] ground-fault pick-up adjustment range
    conforming to IEC with In > 400 A 0.2...1 x In adjustable in step of 10 A
    conforming to IEC with In <= 400 A 0.3...1 x In adjustable in step of 10 A
    Ig enable on/off
    [tg] ground-fault time delay adjustment range
    0.1…0.4 s I²t=on
    0…0.4 s I²t=off
    ground-fault time delay adjustment type
    Adjustable
    zone selective interlocking ZSI
    With
    ground-fault pick-up adjustment type
    Adjustable
    type of measurement
    Power meter
    thermal memory
    Yes
    energy management
    Measurement ,active, reactive and apparent energy (standard)
    Measurement ,electrical network (standard)
    Measurement ,energy (standard)
    metering type
    Current I1, I2, I3, In, Ig: maximum standard)
    Average voltage Vavg standard)
    Active power P, P1, P2, P3 standard)
    Reactive power Q, Q1, Q2, Q3 standard)
    Apparent power S, S1, S2, S3 standard)
    Power factor standard)
    Frequency standard)
    Total current harmonic distortion THD (I): inst, avg, avg min, avg max fundamental voltage standard)
    Total current harmonic distortion THD (I): inst, avg, avg min, avg max RMS voltage standard)
    Voltage V21, V32, V13, V1, V2, V3: instantaneous standard)
    Voltage V21, V32, V13, V1, V2, V3: minimum standard)
    Voltage V21, V32, V13, V1, V2, V3: maximum standard)
    Total voltage harmonic distortion THD (V): inst, avg, avg min, avg max fundamental voltage standard)
    Total voltage harmonic distortion THD (V): inst, avg, avg min, avg max RMS voltage standard)
    Demand current I1, I2, I3, In, Iavg standard)
    Demand power P, Q, S standard)
    network and machine diagnosis type
    System (HMI) health state overview: circuit breaker health state standard)
    Contacts state: circuit breaker health state standard)
    Micrologic service life: circuit breaker health state standard)
    Tripping cause indication: circuit breaker tripping cause standard)
    Identification card: diagnostic data standard)
    Configured alarms synthesis: diagnostic data standard)
    Monitored function: diagnostic data standard)
    Operation: diagnostic data standard)
    Micrologic test: test standard)
    Protection test: test standard)
    Selectivity test: test standard)
    Trip context information: crisis management standard)
    Operation: advanced diagnostic standard)
    Breaker service life: circuit breaker health state standard)
    measurement voltage
    145.6…828 V AC 50/60 Hz per phase
    frequency measurement range
    45…250 Hz
    measurement accuracy
    Power factor: +/- 1 %
    Active energy Ep IN/OUT/tot: +/- 1 % - 10...10 GWh
    Reactive energy Ep IN/OUT/tot: +/- 2 % - 10...10 GVARh
    Apparent energy Es IN/OUT/tot: +/- 1 % - 10...10 GVAh
    Unbalance current: +/- 0.5 %
    Frequency: +/- 0.005 Hz
    Voltage V21, V32, V13, VLLavg: +/- 0.5 % 208...690 x 1.2 V
    Voltage V21, V32, V13, VLNavg: +/- 0.5 % 120...400 x 1.2 V
    Apparent power S, S1, S2, S3, Sdemand: +/- 1 %
    Active power P, P1, P2, P3, Pdemand: +/- 1 %
    Reactive power Q, Q1, Q2, Q3, Qdemand: +/- 2 %
    Current I1, I2, I3, Iavg, Idemand for MTZ1: +/- 0.5 % 40...1600 x 1.2 A
    Current I1, I2, I3, Iavg, Idemand for MTZ2: +/- 0.5 % 40...4000 x 1.2 A
    Current I1, I2, I3, Iavg, Idemand for MTZ3: +/- 0.5 % 80...6300 x 1.2 A
    accuracy class
    Class 5: total current harmonic distortion THD (I)
    Class 0.5: unbalance voltage
    Class 1: active and reactive energy by pulse counting (+/- W.h, +/- VAR.h)
    Class 2: total voltage harmonic distortion THD (V)
    display type
    LCD display - 128 x 96 pixels
    communication port protocol
    Bluetooth 4.0 LE peer to peer 30 kbit/s
    NFC peer to peer conforming to ISO 15963
    USB peer to peer 115 kbauds
    data recording
    Maintenance logs
    Data logs
    Min/max of instantaneous values
    Alarm logs
    Event logs
    Time stamping
    electromagnetic compatibility
    Electrostatic discharge immunity test conforming to IEC 61000-4-2
    Susceptibility to electromagnetic fields conforming to IEC 61000-4-3
    Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
    1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5
    Conducted RF disturbances conforming to IEC 61000-4-6
    Conducted and radiated emissions A conforming to CISPR 22
    Environment
    standards
    IEC 60092-202
    EN/IEC 60255-1
    EN/IEC 60947-2
    EN/IEC 60947-1
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information
    Environmental Disclosure
    Circularity Profile
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages32
    • English15
    • Chinese9
    • French10
    • German3
    • Italian3
    • Portuguese3
    • Russian3
    • Spanish7
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    Catalog MasterPact MTZ 2020 - Air circuit breakers and switch-disconnectors (Version 4.1)
    Description
    Catalog MasterPact MTZ 2020 - Air circuit breakers and switch-disconnectors
    prp.document.label.format pdf
    Size 90.7 MB
    Date 2/13/20
    Description
    Catalog MasterPact MTZ 2020 - Air circuit breakers and switch-disconnectors
    MasterPact MTZ - Catalogue numbers and spare parts 2020 - aIR circuit breakers and switch-disconnectors (Version 2.0)
    Description
    MasterPact MTZ - Catalogue numbers and spare parts 2020 - aIR circuit breakers and switch-disconnectors
    prp.document.label.format pdf
    Size 10.8 MB
    Date 12/6/19
    Description
    MasterPact MTZ - Catalogue numbers and spare parts 2020 - aIR circuit breakers and switch-disconnectors
    Catalogue Masterpact MTZ 2019 - Disjoncteurs et interrupteurs-sectionneurs forte intensité (Version 2.1)
    Description
    Catalogue Masterpact MTZ 2019 - Disjoncteurs et interrupteurs-sectionneurs forte intensité
    prp.document.label.format pdf
    Size 90.1 MB
    Date 6/12/19
    Description
    Catalogue Masterpact MTZ 2019 - Disjoncteurs et interrupteurs-sectionneurs forte intensité
    Masterpact MTZ - Références et pièces détachées - Disjoncteurs et interrupteurs sectionneurs forte intensité (Version 1.1)
    Description
    Masterpact MTZ - Références et pièces détachées - Disjoncteurs et interrupteurs sectionneurs forte intensité
    prp.document.label.format pdf
    Size 10.9 MB
    Date 2/20/18
    Description
    Masterpact MTZ - Références et pièces détachées - Disjoncteurs et interrupteurs sectionneurs forte intensité
    User guide
    Format
    Size
    Date
    Add to My Documents
    MasterPact MTZ - Cybersecurity Guide (Version 02)
    Description
    This guide provides information on cybersecurity aspects for MasterPact™ MTZ circuit breakers withMicroLogic™ X control units to help system designers and operators promote a secure operatingenvironment for the product.
    prp.document.label.format pdf
    Size 663.8 KB
    Date 12/1/19
    Description
    This guide provides information on cybersecurity aspects for MasterPact™ MTZ circuit breakers withMicroLogic™ X control units to help system designers and operators promote a secure operatingenvironment for the product.
    MasterPact MTZ MicroLogic X Control Unit - User Guide (Version 05)
    Description
    The aim of this guide is to provide users, installers, and maintenance personnel with the technicalinformation needed to operate MicroLogic X control units in MasterPact MTZ circuit breakers.
    prp.document.label.format pdf
    Size 6.3 MB
    Date 12/1/19
    Description
    The aim of this guide is to provide users, installers, and maintenance personnel with the technicalinformation needed to operate MicroLogic X control units in MasterPact MTZ circuit breakers.
    Masterpact MTZ -Modbus Communication Guide (Version 05)
    Description
    Masterpact MTZ -Modbus Communication Guide
    prp.document.label.format pdf
    Size 2.9 MB
    Date 5/28/19
    Description
    Masterpact MTZ -Modbus Communication Guide
    Masterpact MTZ - Basic and Standard Maintenance Procedures for IEC Devices (Version 03)
    Description
    This document provides trained and qualified maintenance personnel with the technical information needed to perform Basic and Standard end-user preventive maintenance on Masterpact MTZ IEC circuit breakers and switch-disconnectors.
    prp.document.label.format pdf
    Size 20.4 MB
    Date 3/1/19
    Description
    This document provides trained and qualified maintenance personnel with the technical information needed to perform Basic and Standard end-user preventive maintenance on Masterpact MTZ IEC circuit breakers and switch-disconnectors.
    Masterpact MTZ IEC Circuit Breakers and Switch-Disconnectors - Maintenance Guide (Version 03)
    Description
    This guide contains information on the preventive maintenance Policy recommended to ensure that masterpact MTZ devices retain the operating and technical characteristics specified during their service life.
    prp.document.label.format pdf
    Size 3.8 MB
    Date 3/1/19
    Description
    This guide contains information on the preventive maintenance Policy recommended to ensure that masterpact MTZ devices retain the operating and technical characteristics specified during their service life.
    MasterPact MTZ2/MTZ3 - 800-6300 A IEC 断路器和开关切断器 - 用户指南 (Version 03)
    Description
    本指南旨在提供必要的技术信息,以使用户、安装人员和维护人员能够按照 IEC 标准对MasterPact MTZ2/MTZ3 断路器和 开关切断器 进行操作。
    prp.document.label.format pdf
    Size 11.8 MB
    Date 12/1/19
    Description
    本指南旨在提供必要的技术信息,以使用户、安装人员和维护人员能够按照 IEC 标准对MasterPact MTZ2/MTZ3 断路器和 开关切断器 进行操作。
    Masterpact MTZ Micrologic X - 控制单元 - 用户指南 (Version 05)
    Description
    本指南旨在为用户、安装人员以及维护人员提供在 Masterpact MTZ 断路器上运行 Micrologic X 控制单元所需的技术信息。
    prp.document.label.format pdf
    Size 6.6 MB
    Date 12/1/19
    Description
    本指南旨在为用户、安装人员以及维护人员提供在 Masterpact MTZ 断路器上运行 Micrologic X 控制单元所需的技术信息。
    MasterPact MTZ - 网络安全指南 (Version 02)
    Description
    本指南中的信息涉及带 MicroLogic™ X 控制单元的 MasterPact™ MTZ 断路器的网络安全,旨在帮助系统设计人员和操作人员为产品打造一个安全的运行环境。
    prp.document.label.format pdf
    Size 1 MB
    Date 12/1/19
    Description
    本指南中的信息涉及带 MicroLogic™ X 控制单元的 MasterPact™ MTZ 断路器的网络安全,旨在帮助系统设计人员和操作人员为产品打造一个安全的运行环境。
    Masterpact MTZ Modbus 通信指南 (Version 05)
    Description
    Masterpact MTZ Modbus 通信指南
    prp.document.label.format pdf
    Size 3.1 MB
    Date 6/1/19
    Description
    Masterpact MTZ Modbus 通信指南
    Masterpact MTZ - IEC 断路器和开关切断器 - 维护指南 (Version 03)
    Description
    本指南中的信息涉及:- 要执行的预防性维护计划,以及各项计划所需的技能水平。- 根据环境和工作条件以及用户应用的严重程度确定的维护频率。
    prp.document.label.format pdf
    Size 4 MB
    Date 3/1/19
    Description
    本指南中的信息涉及:- 要执行的预防性维护计划,以及各项计划所需的技能水平。- 根据环境和工作条件以及用户应用的严重程度确定的维护频率。
    Masterpact MTZ - IEC 设备用户基本和标准维护程序 (Version 03)
    Description
    本文档旨在为接受过相应培训且具备相应资质的人员提供对以下设备执行用户基本和标准预防性维护时所需的技术信息:- Masterpact MTZ1 IEC 断路器和开关切断器- Masterpact MTZ2/MTZ3 IEC 断路器和开关切断器
    prp.document.label.format pdf
    Size 21 MB
    Date 3/1/19
    Description
    本文档旨在为接受过相应培训且具备相应资质的人员提供对以下设备执行用户基本和标准预防性维护时所需的技术信息:- Masterpact MTZ1 IEC 断路器和开关切断器- Masterpact MTZ2/MTZ3 IEC 断路器和开关切断器
    MasterPact MTZ - Guide de cybersécurité (Version 02)
    Description
    Ce guide fournit des informations sur la cybersécurité des disjoncteurs MasterPact™ MTZ avec unités decontrôle MicroLogic™ X, pour aider les concepteurs et les utilisateurs de système à mettre en place unenvironnement sécurisé d'exploitation du produit.
    prp.document.label.format pdf
    Size 1.3 MB
    Date 12/1/19
    Description
    Ce guide fournit des informations sur la cybersécurité des disjoncteurs MasterPact™ MTZ avec unités decontrôle MicroLogic™ X, pour aider les concepteurs et les utilisateurs de système à mettre en place unenvironnement sécurisé d'exploitation du produit.
    MasterPact MTZ MicroLogic X - Unité de contrôle - Guide d'exploitation (Version 05)
    Description
    L'objet de ce guide est de fournir aux utilisateurs, aux installateurs et au personnel de maintenance lesinformations techniques nécessaires à l’exploitation des unités de contrôle Micrologic X sur lesdisjoncteurs Masterpact MTZ.
    prp.document.label.format pdf
    Size 7.2 MB
    Date 12/1/19
    Description
    L'objet de ce guide est de fournir aux utilisateurs, aux installateurs et au personnel de maintenance lesinformations techniques nécessaires à l’exploitation des unités de contrôle Micrologic X sur lesdisjoncteurs Masterpact MTZ.
    Masterpact MTZ Guide de communication Modbus (Version 05)
    Description
    Masterpact MTZ Guide de communication Modbus
    prp.document.label.format pdf
    Size 3.1 MB
    Date 6/1/19
    Description
    Masterpact MTZ Guide de communication Modbus
    Masterpact MTZ - Disjoncteurs et interrupteurs-sectionneurs CEI - Guide de maintenance (Version 03)
    Description
    Ce guide fournit des informations sur les programmes de maintenance préventive recommandés afin de préserver les caractéristiques de fonctionnement et de sécurité indiquées dans les catalogues tout au long de la durée de vie dun disjoncteur Masterpact MTZ.
    prp.document.label.format pdf
    Size 4.1 MB
    Date 3/1/19
    Description
    Ce guide fournit des informations sur les programmes de maintenance préventive recommandés afin de préserver les caractéristiques de fonctionnement et de sécurité indiquées dans les catalogues tout au long de la durée de vie dun disjoncteur Masterpact MTZ.
    Masterpact MTZ - Procédures de maintenance de base et standard utilisateur pour appareils IEC (Version 03)
    Description
    Lobjectif de ce document est de fournir au personnel formé et qualifié les informations techniques nécessaires pour assurer la maintenance préventive (de base ou standard) utilisateur sur les disjoncteurs et interrupteurs-sectionneurs Masterpact MTZ IEC.
    prp.document.label.format pdf
    Size 20.9 MB
    Date 3/1/19
    Description
    Lobjectif de ce document est de fournir au personnel formé et qualifié les informations techniques nécessaires pour assurer la maintenance préventive (de base ou standard) utilisateur sur les disjoncteurs et interrupteurs-sectionneurs Masterpact MTZ IEC.
    MasterPact MTZ - Guía de ciberseguridad (Version 02)
    Description
    Esta guía proporciona información sobre aspectos de ciberseguridad para interruptores automáticosMasterPact™ MTZ con unidades de control MicroLogic™ X para ayudar a los diseñadores y operadoresde sistemas a promover un entorno de funcionamiento seguro para el producto.
    prp.document.label.format pdf
    Size 1.3 MB
    Date 12/1/19
    Description
    Esta guía proporciona información sobre aspectos de ciberseguridad para interruptores automáticosMasterPact™ MTZ con unidades de control MicroLogic™ X para ayudar a los diseñadores y operadoresde sistemas a promover un entorno de funcionamiento seguro para el producto.
    MasterPact MTZ MicroLogic X - Unidad de control - Guía del usuario (Version 05)
    Description
    El objetivo de esta guía es proporcionar a los usuarios, los instaladores y el personal de mantenimiento lainformación técnica necesaria para utilizar las unidades de control MicroLogic™ X de los interruptoresautomáticos MasterPact™ MTZ.
    prp.document.label.format pdf
    Size 6.5 MB
    Date 12/1/19
    Description
    El objetivo de esta guía es proporcionar a los usuarios, los instaladores y el personal de mantenimiento lainformación técnica necesaria para utilizar las unidades de control MicroLogic™ X de los interruptoresautomáticos MasterPact™ MTZ.
    Masterpact MTZ Guía de comunicación Modbus (Version 05)
    Description
    Masterpact MTZ Guía de comunicación Modbus
    prp.document.label.format pdf
    Size 3.1 MB
    Date 6/1/19
    Description
    Masterpact MTZ Guía de comunicación Modbus
    Masterpact MTZ - Procedimientos de mantenimiento básico y estándar del usuario para aparatos IEC (Version 03)
    Description
    El objetivo de este documento es proporcionar al personal de mantenimiento formado y cualificado lainformación técnica necesaria para llevar a cabo el mantenimiento preventivo básico y estándar delusuario en interruptores automáticos e interruptores en carga Masterpact MTZ IEC.
    prp.document.label.format pdf
    Size 21.6 MB
    Date 3/1/19
    Description
    El objetivo de este documento es proporcionar al personal de mantenimiento formado y cualificado lainformación técnica necesaria para llevar a cabo el mantenimiento preventivo básico y estándar delusuario en interruptores automáticos e interruptores en carga Masterpact MTZ IEC.
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 902.3 KB
    Date 9/1/18
    prp.document.label.format pdf
    Size 11.2 MB
    Date 9/1/17
    prp.document.label.format pdf
    Size 23.8 MB
    Date 9/1/17
    China RoHS declaration
    Format
    Size
    Date