Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all PowerLogic ION8800
Schneider Electric M8800B2C0B5E0A0A Image

M8800B2C0B5E0A0A

Schneider Electric M8800B2C0B5E0A0A Image
M8800B2C0B5E0A0A

M8800B energy meter - 5 MB - class A - 5 A input - 50 Hz

Show more characteristics
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range
    PowerLogic
    device short name
    ION8800B
    product or component type
    Energy and power quality meter
    Complementary
    power quality analysis
    conforming to IEC 61000-4-30: class S power quality measurement
    conforming to IEC 61000-4-15 flicker
    magnitude harmonic up to the 50th
    conforming to IEEE 519: 1992 harmonic control
    conforming to IEEE 1159: 1995 power quality monitoring
    symmetrical component
    transient detection (20 µs)
    voltage sag and swell detection
    programmablity (logic and math functions)
    up to the 63rd harmonic
    conforming to IEC 61000-4-30: class A power quality measurement
    conforming to EN 50160 compliance report
    device application
    Contract optimisation
    Equipment monitoring and control
    Load curtailment
    Tariff metering
    Instrument transformer correction
    Co-generation and IPP monitoring
    Power monitoring
    Demand and power factor control
    Energy pulsing and totalisation
    type of measurement
    Current
    Voltage
    Frequency
    Apparent power total
    Power factor total
    Apparent power per phase
    Power factor per phase
    Active power total
    Active power per phase
    Reactive power total
    Reactive power per phase
    supply voltage
    85...240 V AC 47...63 Hz
    110...270 V DC
    network frequency
    50 Hz
    [In] rated current
    5 A
    type of network
    3P + N
    3P
    1P + N
    power consumption in VA
    19 VA
    maximum power consumption in VA
    32 VA
    display type
    FSTN transflective LCD
    sampling rate
    1024 samples/cycle
    measurement current
    0…5 A
    input type
    Current 0.001...10 A (impedance 0.01 Ohm)
    measurement voltage
    57…288 V AC phase to neutral
    99…500 V AC phase to phase
    frequency measurement range
    47…63 Hz
    number of inputs
    0
    measurement accuracy
    Current 0.1 %
    Voltage 0.1 %
    Power 0.2 %
    Power factor 0.1 %
    Frequency 0.005 Hz
    Energy 0.2 %
    accuracy class
    Class 0.2S active energy conforming to IEC 62053-22
    Class 0.2S reactive energy conforming to IEC 62053-23
    number of outputs
    1 alarm output
    8 form A triac output
    4 form C solid state output
    2 IEC 1107 pulse
    communication port protocol
    DLMS
    ION
    TCP/IP at 10/100 Mbit/s
    DNP3
    Modbus RTU, master/slave at <= 19200 bauds
    Modbus RTU, master/slave at 300...57600 bauds
    Modbus RTU, master/slave at 300...115200 bauds
    Modbus TCP, master/slave at 10/100 Mbit/s
    IEC 1107 at <= 19200 bauds
    communication port support
    Screw terminal block: RS485
    RJ45: Ethernet
    Infrared
    DB9: RS485/RS232
    data recording
    Time stamping
    Waveform logs
    Historical logs
    Data logs
    GPS synchronisation
    Transient logs
    Alarms
    Min/max of instantaneous values
    transmission rate
    <= 19200 bauds
    10/100 Mbit/s
    300...115200 bauds
    300...57600 bauds
    memory capacity
    5 MB
    web services
    Web server
    tamperproof of settings
    Protected by access code
    compatibility code
    ION8800B
    Environment
    electromagnetic compatibility
    Conducted RF disturbances conforming to IEC 61000-4-6
    Immunity to impulse waves conforming to IEC 61000-4-12
    Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
    Electrostatic discharge conforming to IEC 61000-4-2
    Susceptibility to electromagnetic fields conforming to IEC 61000-4-3
    1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5
    Conducted and radiated emissions B conforming to CISPR 22
    mounting mode
    Rack-mounted
    enclosure type
    19" rack
    type of installation
    Indoor installation
    overvoltage category
    III
    IP degree of protection
    IP51 conforming to IEC 60529
    relative humidity
    5…95 %
    pollution degree
    2
    ambient air temperature for operation
    -10…45 °C
    ambient air temperature for storage
    -25…70 °C
    operating altitude
    0...2000 m
    product certifications
    EGR
    ESKOM
    GOST
    NMI
    standards
    IEC 62052-11
    IEC 60950
    width
    202.1 mm
    depth
    261.51 mm
    height
    132.2 mm
    net weight
    6 kg
    Offer Sustainability
    EU RoHS Directive
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages22
    • English22
    • Russian2
    User guide
    Format
    Size
    Date
    Add to My Documents
    DLMS/COSEM and ION technology (Version 04)
    Description
    This protocol document provides setup instructions for using DLMS/COSEM withPowerLogic ION8650 (firmware v406 and later), ION7400 (firmware v1.4.1 andlater) and ION8800 (firmware v350 and later) meters.
    Size pdf
    Size 147.4 KB
    Date 7/1/19
    Description
    This protocol document provides setup instructions for using DLMS/COSEM withPowerLogic ION8650 (firmware v406 and later), ION7400 (firmware v1.4.1 andlater) and ION8800 (firmware v350 and later) meters.
    ION Reference -EN (Version 10)
    Description
    Overview of ION architecture and details of all ION modules
    Size pdf
    Size 9.5 MB
    Date 10/26/18
    Description
    Overview of ION architecture and details of all ION modules
    Size chm
    Size 18 MB
    Date 10/16/18
    IEC 61000-4-30 compliance and ION meters -EN (Version 12)
    Description
    This technical note outlines the compliance of applicable PowerLogic meters with the International Electrotechnical Commission’s IEC 61000-4-30 (or “4-30”) standard, and is intended for personnel with knowledge of power quality and power quality standards.
    Size pdf
    Size 111.4 KB
    Date 10/5/18
    Description
    This technical note outlines the compliance of applicable PowerLogic meters with the International Electrotechnical Commission’s IEC 61000-4-30 (or “4-30”) standard, and is intended for personnel with knowledge of power quality and power quality standards.
    PowerLogic ION8800 user manual (Version 03)
    Description
    this document explains how to configure and operate ION8800 meters
    Size pdf
    Size 2.9 MB
    Date 4/19/18
    Description
    this document explains how to configure and operate ION8800 meters
    What's new in PowerLogic ION8800 firmware version 370 (Version 00)
    Description
    This document contains information regarding updates and new features in PowerLogic ION8800 version 370.
    Size pdf
    Size 108.5 KB
    Date 3/29/18
    Description
    This document contains information regarding updates and new features in PowerLogic ION8800 version 370.
    PowerLogic ION8800 Installation Guide - EN (Version 2)
    Description
    This installation guide for PowerLogic ION8800 meters describes mounting, wiring, connecting and verifying operation of the meter.
    Size pdf
    Size 1.2 MB
    Date 9/1/16
    Description
    This installation guide for PowerLogic ION8800 meters describes mounting, wiring, connecting and verifying operation of the meter.
    Certificate
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 1.1 MB
    Date 11/14/18
    Size pdf
    Size 722.6 KB
    Date 11/14/18
    Size pdf
    Size 683.5 KB
    Date 11/14/18
    Size pdf
    Size 100.7 KB
    Date 11/14/18
    Size pdf
    Size 659.6 KB
    Date 11/14/18
    Size pdf
    Size 639.2 KB
    Date 11/14/18
    Size pdf
    Size 1.1 MB
    Date 4/20/16
    Size pdf
    Size 659.6 KB
    Date 4/14/16
    Size pdf
    Size 683.5 KB
    Date 10/2/12
    Size pdf
    Size 98.1 KB
    Date 10/10/11
    Size pdf
    Size 227.3 KB
    Date 8/3/06
    Catalogue page
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 767.9 KB
    Date 4/7/12
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 272.3 KB
    Date 7/29/19
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    M8800B energy meter - 5 MB - class A - 5 A input - 50 Hz
    Description
    M8800B energy meter - 5 MB - class A - 5 A input - 50 Hz
    Size pdf
    Size 195.3 KB
    Date 11/20/19
    Description
    M8800B energy meter - 5 MB - class A - 5 A input - 50 Hz
    Technical leaflet
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 601.4 KB
    Date 11/30/17
  • View more View less

    Software and Firmware

    Language
    • English3
    Firmware - Released
    Format
    Size
    Date
    Add to My Documents
    ION8800 V370 Firmware and templates (Version 1.0)
    Files in document
    upg
    2.5 MB
    upg
    3 MB
    upg
    2.5 MB
    upg
    3 MB
    upg
    2.5 MB
    upg
    3 MB
    Description
    This release brings updates required to comply with IEC 4-30 Edition 3, as well as updates to EN50160. Firmware file SHA256 checksums: V370_8800A.upg: 64d9857732d68e1cc7f92e1bf1cf3cd69ad769585b35b9182c5e7b31f7f06e9f V370_8800A_61850.upg: f07d4f065504f0de587b473ad70216ebf58efcc641a4e29f9b85f87e63f373ba V370_8800B.upg: fcb3b6e8a12d61124e5521e011d99f04de8a327ab8497dee33f4c5eed975af16 V370_8800B_61850.upg: d5862d45829f530aff432ad71ede816d03ef8e4f831a251745988e47aa0fbb98 V370_8800C.upg: 1b4c6112997a606cd442c42cf75d924bd702ad1c648aad8b6651505e418cb172 V370_8800C_61850.upg: 9149dfd71f3ca08225f486f6bb91768b51cd7e286da65837bf91065325f3fcfa
    Size zip
    Size 18.2 MB
    Date 6/11/18
    Files in document
    upg
    2.5 MB
    upg
    3 MB
    upg
    2.5 MB
    upg
    3 MB
    upg
    2.5 MB
    upg
    3 MB
    Description
    This release brings updates required to comply with IEC 4-30 Edition 3, as well as updates to EN50160. Firmware file SHA256 checksums: V370_8800A.upg: 64d9857732d68e1cc7f92e1bf1cf3cd69ad769585b35b9182c5e7b31f7f06e9f V370_8800A_61850.upg: f07d4f065504f0de587b473ad70216ebf58efcc641a4e29f9b85f87e63f373ba V370_8800B.upg: fcb3b6e8a12d61124e5521e011d99f04de8a327ab8497dee33f4c5eed975af16 V370_8800B_61850.upg: d5862d45829f530aff432ad71ede816d03ef8e4f831a251745988e47aa0fbb98 V370_8800C.upg: 1b4c6112997a606cd442c42cf75d924bd702ad1c648aad8b6651505e418cb172 V370_8800C_61850.upg: 9149dfd71f3ca08225f486f6bb91768b51cd7e286da65837bf91065325f3fcfa
    ION8800 V362 Template (Version 1.0)
    Description
    ION Setup is the recommended software tool (freeware downloadable utility) for updating your meter to this template. Note that these template files are supported by firmware version v362 or higher. For specific instructions on the firmware upgrade process, see the "Upgrading ION Device Firmware" technical note. Be sure to use the correct template for your application.
    Size zip
    Size 416.7 KB
    Date 3/30/17
    Description
    ION Setup is the recommended software tool (freeware downloadable utility) for updating your meter to this template. Note that these template files are supported by firmware version v362 or higher. For specific instructions on the firmware upgrade process, see the "Upgrading ION Device Firmware" technical note. Be sure to use the correct template for your application.
    ION8800 V362 Firmware (Version 1.0)
    Description
    The key changes introduced in V362 are cyber security and IEC61850 Edition 2 upgrades. 8800v362_ABC.zip SHA256 checksum: E225D6244002B3C15AE5D27666E04624E9328F6347B775C164F8F6466AFAEED0
    Size zip
    Size 7.6 MB
    Date 7/29/16
    Description
    The key changes introduced in V362 are cyber security and IEC61850 Edition 2 upgrades. 8800v362_ABC.zip SHA256 checksum: E225D6244002B3C15AE5D27666E04624E9328F6347B775C164F8F6466AFAEED0
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /