  • Main
    range
    PowerLogic
    device short name
    ION92030
    product or component type
    Energy and power quality meter
    device application
    Power monitoring
    WAGES metering
    Net metering
    Medium voltage
    High voltage
    metering type
    Demand current I1, I2, I3, I4, I5
    Peak demand currents
    Demand power P, Q, S
    Peak demand power PM, QM, SM
    Calculated active and reactive energy (+/- W.h, +/- VAR.h)
    Complementary
    power quality analysis
    EN 50160 compliance checking
    conforming to IEEE 519 harmonic limit
    conforming to IEC 61000-4-30: class A compliance reporting
    conforming to IEEE 519 compliance reporting
    waveform capture
    total demand distortion
    total harmonic distortion
    up to the 63rd harmonic
    up to the 127th harmonic with software
    disturbance direction detection
    dip, swell and transient
    half cycle data acquisition
    transient detection (20 µs)
    type of measurement
    Voltage sags and swells
    Current sags and swells
    Voltage
    Current
    Frequency
    Active and reactive power total
    Apparent power total
    Active and reactive power per phase
    Apparent power per phase
    Power factor total
    Power factor per phase
    Active and reactive energy
    Apparent energy
    Harmonic distorsion (I THD & U THD)
    [Us] rated supply voltage
    90...480 V AC 45...66 Hz +/- 10 %
    90...120 V AC 400 Hz +/- 10 %
    110...480 V DC +/- 15 %
    network frequency
    50 Hz
    60 Hz
    ride-through time
    100 ms 6 cycles at 60 Hz 120 V AC typical
    400 ms 24 cycles at 60 Hz 240 V AC typical
    1200 ms 72 cycles at 60 Hz 480 V AC typical
    [In] rated current
    1 A
    5 A
    20 A
    type of network
    3P + N + E
    power consumption in VA
    38 VA at 480 V AC
    maximum power consumption in VA
    80 VA at 480 V AC
    display type
    Without display
    sampling rate
    1024 samples/cycle
    measurement current
    0.01…20 A
    input type
    Voltage (impedance 5 MOhm)
    Current (impedance 0.3 mOhm)5 x
    measurement voltage
    57…400 V AC 42...69 Hz between phase and neutral
    100…690 V AC 42...69 Hz between phases
    frequency measurement range
    20…450 Hz
    number of inputs
    8 digital 30 V AC/60 V DC
    measurement accuracy
    Voltage +/- 0.1 %
    Current +/- 0.1 %
    accuracy class
    Class 0.1S active energy conforming to IEC 62053-22
    Class 0.1 active energy conforming to IEC 61557-12
    Class 0.1 active energy conforming to ANSI C12.20
    Class 0.5S reactive energy conforming to IEC 62053-24
    Class 0.1 current conforming to IEC 61557-12
    Class 0.1 voltage conforming to IEC 61557-12
    Class 0.1 active power conforming to IEC 61557-12
    Class 0.5 power factor conforming to IEC 61557-12
    number of outputs
    4 digital
    2 form C relay
    communication port protocol
    Modbus RTU at 2400...115200 bps - 2-wire
    ION at 2400...115200 bps - 2-wire
    DNP3 at 2400...115200 bps - 2-wire
    Modbus TCP at 10/100 Mbit/s
    ION TCP at 10/100 Mbit/s
    DNP3 TCP at 10/100 Mbit/s
    IEC 61850
    Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s
    DHCP
    DNS
    DLMS
    communication port support
    RS485 2 removable screw terminal block
    port Ethernet
    10/100BASE-TX 2 RJ45
    communication gateway
    Ethernet/serial
    time synchronisation protocol
    GPS
    IRIG-B
    NTP
    SNTP
    PTP
    data recording
    Time stamping
    Min/max of instantaneous values
    User-definable data logs
    Continuous logging or snapshot
    Trending/forecasting
    Event logs
    Alarm logs
    Configuration change
    Power outage
    User login/logout
    Data logs
    GPS synchronisation
    Sequence of event recording
    memory capacity
    2 GB
    cybersecurity
    Syslog protocol support
    Robust security logs
    Port hardening
    Enable/disable communication ports
    Hardware metrology lock
    web services
    Viewing of captured waveform
    Web page
    Pass/fail report for IEEE 519
    Pass/fail report for EN 50160
    ITIC (CBEMA) curve
    SEMI curve
    NEMA motor derating curve
    Alarm notification by e-mail
    TLS 1.2
    Push historical data via mail
    Ethernet service
    DHCP client
    Device Profile Web Services (DPWS)
    Rapid Scanning Tree Protocol (RSTP)
    FTP/HTTP/HTTPS
    communication service
    Compliant reports
    Power quality summary
    Energy report
    EcoStruxure Power Events Analysis
    SMTP e-mail notification
    SNMP
    tamperproof of settings
    Protected by sealable cover
    mounting support
    DIN rail
    electrical insulation class
    Class III conforming to EN/IEC 62052-11
    isolation voltage
    III, 400…690 V conforming to EN 61010-1:ed. 3
    III, 347…600 V conforming to UL 61010-1:ed. 3
    III, 347…600 V conforming to CSA C22.2 No 61010-1:ed. 3
    width
    160 mm
    depth
    135.3 mm
    height
    160 mm
    net weight
    1.5 kg
    Environment
    electromagnetic compatibility
    EMC immunity conforming to IEC 62052-11
    EMC immunity conforming to IEC 61326-1
    EMC immunity conforming to IEC 61000-6-5
    Electrostatic discharge immunity test conforming to IEC 61000-4-2
    Immunity to radiated fields conforming to IEC 61000-4-3
    Immunity to fast transients conforming to IEC 61000-4-4
    Surge immunity test conforming to IEC 61000-4-5
    Immunity to conducted disturbances conforming to IEC 61000-4-6
    Immunity to magnetic fields at network frequency conforming to IEC 61000-4-8
    Immunity to conducted disturbances - test level: 2...150 kHz conforming to CLC/TR 50579
    Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
    Immunity to impulse waves conforming to IEC 61000-4-12
    Conducted and radiated emissions conforming to EN 55011
    Conducted and radiated emissions class B conforming to EN 55032
    Conducted and radiated emissions class B conforming to FCC part 15
    Conducted and radiated emissions class B conforming to ICES-003
    Surge withstand conforming to ANSI C37.90.1
    Surge withstand conforming to IEEE C37.90.1
    IP degree of protection
    IP65 front:
    IP30 rear:
    degree of protection
    UL type 12, front
    relative humidity
    5…95 %
    ambient air temperature for operation
    -25…70 °C
    ambient air temperature for storage
    -40…85 °C
    installation category
    III
    operating altitude
    0...3000 m
    standards
    ANSI C12.20
    ANSI C37.90.1
    IEC 61000-4-15
    IEC 61000-4-30
    IEC 61010-1
    IEC 61326-1
    IEC 61557-12
    IEC 61850
    IEC 62052-11
    IEC 62052-31
    IEC 62053-22
    IEC 62053-23
    IEC 62053-24
    IEC 62586
    UL 61010-1
    quality labels
    ISO 9001
    ISO 14000
    Packing Units
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Weight
    2.5 kg
    Package 1 Height
    30 cm
    Package 1 width
    30 cm
    Package 1 Length
    41 cm
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
  • View more View less

    Documents

    Language
    • All Languages18
    • English18
    • Chinese2
    • French3
    • German2
    • Italian2
    • Portuguese2
    • Russian2
    • Spanish3
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    PowerLogic Catalog - 247 pages Web (NO PRINTED VERSION AVAILABLE) (Version 8.5)
    Description
    Note that no printed catalogs are available but all necessary source files, in 13 sections, are available for download from the Shopping Kiosk.
    prp.document.label.format pdf
    Size 12.3 MB
    Date 1/25/20
    Description
    Note that no printed catalogs are available but all necessary source files, in 13 sections, are available for download from the Shopping Kiosk.
    User guide
    Format
    Size
    Date
    Add to My Documents
    ION Reference (Version 11)
    Description
    Overview of ION architecture and details of all ION modules
    prp.document.label.format pdf
    Size 9.6 MB
    Date 1/1/20
    Description
    Overview of ION architecture and details of all ION modules
    PowerLogic ION9000 series user manual (Version 03)
    Description
    This document explains how to configure and operate ION9000 meters.
    prp.document.label.format pdf
    Size 13.9 MB
    Date 11/1/19
    Description
    This document explains how to configure and operate ION9000 meters.
    Upgrade PM89RD96 display firmware to v4.0.15 (Version 03)
    Description
    This document describes the process to upgrade RD96 display firmware to the latest version for use with PowerLogic™ ION9000, PM8000 or ION7400 series meters.
    prp.document.label.format pdf
    Size 167.3 KB
    Date 11/1/19
    Description
    This document describes the process to upgrade RD96 display firmware to the latest version for use with PowerLogic™ ION9000, PM8000 or ION7400 series meters.
    What’s new for Power and Energy Monitoring Systems — November 2019 (Version 00)
    Description
    This update provides a summary of technological advances in the Power and Energy Monitoring System offers, and the technical documentation accompanying their release.
    prp.document.label.format pdf
    Size 95.2 KB
    Date 11/1/19
    Description
    This update provides a summary of technological advances in the Power and Energy Monitoring System offers, and the technical documentation accompanying their release.
    Upgrade meter firmware to v2.2.1 (Version 03)
    Description
    This document describes the process to upgrade PowerLogic™ ION9000, PM8000 or ION7400 series meters to the latest firmware version. It also contains information about upgrading analog I/O option module firmware.
    prp.document.label.format pdf
    Size 947.6 KB
    Date 11/1/19
    Description
    This document describes the process to upgrade PowerLogic™ ION9000, PM8000 or ION7400 series meters to the latest firmware version. It also contains information about upgrading analog I/O option module firmware.
    IEC 61000-4-30 compliance and ION meters (Version 13)
    Description
    This technical note outlines the compliance of applicable PowerLogic meters with the International Electrotechnical Commission’s IEC 61000-4-30 (or “4-30”) standard, and is intended for personnelwith knowledge of power quality and power quality standards.
    prp.document.label.format pdf
    Size 112.4 KB
    Date 9/1/19
    Description
    This technical note outlines the compliance of applicable PowerLogic meters with the International Electrotechnical Commission’s IEC 61000-4-30 (or “4-30”) standard, and is intended for personnelwith knowledge of power quality and power quality standards.
    DLMS/COSEM and ION technology (Version 04)
    Description
    This protocol document provides setup instructions for using DLMS/COSEM withPowerLogic ION8650 (firmware v406 and later), ION7400 (firmware v1.4.1 andlater) and ION8800 (firmware v350 and later) meters.
    prp.document.label.format pdf
    Size 147.4 KB
    Date 7/1/19
    Description
    This protocol document provides setup instructions for using DLMS/COSEM withPowerLogic ION8650 (firmware v406 and later), ION7400 (firmware v1.4.1 andlater) and ION8800 (firmware v350 and later) meters.
    What’s new in ION9000 series meter firmware v2.1.0 (Version 00)
    Description
    ION9000 firmware version 2.1.0 updates: 0-20 mA Analog I/O option module support, UPG to UPX firmware upgrade enhancement
    prp.document.label.format pdf
    Size 84.1 KB
    Date 2/1/19
    Description
    ION9000 firmware version 2.1.0 updates: 0-20 mA Analog I/O option module support, UPG to UPX firmware upgrade enhancement
    prp.document.label.format chm
    Size 18 MB
    Date 10/16/18
    prp.document.label.format pdf
    Size 11.9 MB
    Date 8/1/18
    prp.document.label.format pdf
    Size 11.4 MB
    Date 8/1/18
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    PowerLogic ION9000 installation guide (Version 02)
    Description
    Installation sheet for PowerLogic ION9000 power and energy meters describes mounting, wiring, connecting and verifying operation of the meter.
    prp.document.label.format pdf
    Size 14.8 MB
    Date 10/1/19
    Description
    Installation sheet for PowerLogic ION9000 power and energy meters describes mounting, wiring, connecting and verifying operation of the meter.
    PowerLogic Analog I/O option module (Version 00)
    Description
    Installation instructions
    prp.document.label.format pdf
    Size 5.3 MB
    Date 3/1/19
    Description
    Installation instructions
    PowerLogic METSE7X4MAK ION9000 Adapter Plate Install Sheet (Version 00)
    Description
    ION9000 series meter mounting adapter kit installation sheet for ION7550 and ION7650 meter panel cutouts.
    prp.document.label.format pdf
    Size 2.7 MB
    Date 10/17/18
    Description
    ION9000 series meter mounting adapter kit installation sheet for ION7550 and ION7650 meter panel cutouts.
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    METSEION92030 : PowerLogic™ ION9000 meter, DIN mount, no display, HW kit
    Description
    PowerLogic™ ION9000 meter, DIN mount, no display, HW kit
    prp.document.label.format pdf
    Size 195.3 KB
    Date 7/8/20
    Description
    PowerLogic™ ION9000 meter, DIN mount, no display, HW kit
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    METSEION92030 : PowerLogic™ ION9000 meter, DIN mount, no display, HW kit
    Description
    PowerLogic™ ION9000 meter, DIN mount, no display, HW kit
    prp.document.label.format pdf
    Size 195.3 KB
    Date 7/8/20
    Description
    PowerLogic™ ION9000 meter, DIN mount, no display, HW kit
    Technical leaflet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 617.4 KB
    Date 8/29/19
  • View more View less

    Software and Firmware

    Language
    • English8
    Firmware
    Format
    Size
    Date
    Add to My Documents
    ION9000 v2.2.1 Firmware and Associated Files (Version v2.2.1)
    Files in document
    Description
    This ZIP file contains the files to upgrade the PowerLogic™ ION9000 series meter to firmware v2.2.1 (V002.002.001), Meter Template, Modbus Map document, SNMP MIB, Webpages, What’s new document and other associated files. See the Upgrading Meter Firmware to v2.2.1 document for important information on performing this upgrade. Verify the checksum of the file to help ensure it was not corrupted during download using the SHA-256 File Signature for the ION9000_V002.002.001.zip file: 5fe6c4c69d5c427c01d2f32dad2339838eb306219f30fe7e7ea7847fa4a1192b. NOTE: To apply this firmware, the meter must have firmware v2.1.0. Go to schneider-electric.com and search for Upgrade devices to firmware v 2.1.0 and follow instructions on how to get and apply firmware v2.1.0.
    prp.document.label.format zip
    Size 19.9 MB
    Date 11/20/19
    Files in document
    Description
    This ZIP file contains the files to upgrade the PowerLogic™ ION9000 series meter to firmware v2.2.1 (V002.002.001), Meter Template, Modbus Map document, SNMP MIB, Webpages, What’s new document and other associated files. See the Upgrading Meter Firmware to v2.2.1 document for important information on performing this upgrade. Verify the checksum of the file to help ensure it was not corrupted during download using the SHA-256 File Signature for the ION9000_V002.002.001.zip file: 5fe6c4c69d5c427c01d2f32dad2339838eb306219f30fe7e7ea7847fa4a1192b. NOTE: To apply this firmware, the meter must have firmware v2.1.0. Go to schneider-electric.com and search for Upgrade devices to firmware v 2.1.0 and follow instructions on how to get and apply firmware v2.1.0.