  • Main
    range
    ClimaSys
    product name
    ClimaSys CV
    product or component type
    Fan
    range compatibility
    Spacial
    Prisma P
    Prisma G
    Type of filter
    G2
    Flow rate
    Free flow rate with standard filter: 562 m3/h at 50 Hz
    Free flow rate with standard filter: 586 m3/h at 60 Hz
    [Us] rated supply voltage
    207...244 V
    input voltage
    230 V 50/60 Hz
    Certification
    CE
    EAC
    REACH
    RoHS
    EMC directive 89/336 EEC
    additional information
    1 line of 10 characters maximum
    Complementary
    Absorbed power
    68 W 50 Hz
    85 W 60 Hz
    [In] rated current
    0.52 A 50 Hz
    0.87 A 60 Hz
    Noise level < at
    59 dB
    bearing type
    Ball
    height
    336 mm external:
    width
    316 mm external:
    depth
    161 mm external:
    cut-out dimensions
    291 x 291 mm
    net weight
    3.480 kg
    material
    Outlet grille: injected thermoplastic (PC)
    Motor support: injected thermoplastic (ASA PC)
    colour
    Outlet grille: smoked black (RAL 9005)
    Motor support: black (RAL 9005)
    ambient air temperature for operation
    -15…60 °C
    ambient air temperature for storage
    -40…70 °C
    maximum pressure
    140 Pa flow rate 0 m³/h
    connections - terminals
    Terminal block
    IP degree of protection
    IP54
    device composition
    1 axial motor
    1 external protective transparent smoked grille: front
    1 smart filter with dust sensor
    1 fan sensor ready to be mounted: rear of outlet grille
    1 cable gland
    1 cut-out template
    condition of use
    Filter must be cleaned and replaced regularly
    Flow rates depends on the work point, see ProClima software
    Overfrequent filter replacement should be avoided
    Surrounding environment must be relatively clean
    Outside temperature must be 5 °C lower than inside temperature
    Offer Sustainability
    REACh Regulation
    REACh free of SVHC
    Yes
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
  • View more View less

    Documents

    Language
    • All Languages9
    • English9
    • French4
    • Spanish4
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    Universal Enclosures - Catalogue 2020 (Version 1.0)
    Description
    This catalogue includes Spacial S3D ranges
    Size pdf
    Size 84.4 MB
    Date 10/18/19
    Description
    This catalogue includes Spacial S3D ranges
    CAD
    Format
    Size
    Date
    Add to My Documents
    Size stp
    Size 11.8 MB
    Date 6/20/19
    Brochure
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 204.1 MB
    Date 6/13/19
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 14.9 MB
    Date 3/28/19
    Catalogue page
    Format
    Size
    Date
    Add to My Documents
    Size zip
    Size 9.3 MB
    Date 3/28/19
    Files in document
    pdf
    3 MB
    pdf
    6.3 MB
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    NSYCVF560M230DG : ClimaSys CV - CSVS SmartFan 560m3/h 230V IP54
    Description
    ClimaSys CV - CSVS SmartFan 560m3/h 230V IP54
    Size pdf
    Size 195.3 KB
    Date 12/12/19
    Description
    ClimaSys CV - CSVS SmartFan 560m3/h 230V IP54
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    NSYCVF560M230DG : ClimaSys CV - CSVS SmartFan 560m3/h 230V IP54
    Description
    ClimaSys CV - CSVS SmartFan 560m3/h 230V IP54
    Size pdf
    Size 195.3 KB
    Date 12/12/19
    Description
    ClimaSys CV - CSVS SmartFan 560m3/h 230V IP54
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    NSYCVF560M230DG : ClimaSys CV - CSVS SmartFan 560m3/h 230V IP54
    Description
    ClimaSys CV - CSVS SmartFan 560m3/h 230V IP54
    Size pdf
    Size 195.3 KB
    Date 12/12/19
    Description
    ClimaSys CV - CSVS SmartFan 560m3/h 230V IP54
    System user guide
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 14.9 MB
    Date 7/3/19
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /