Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Modicon Premium
Schneider Electric TSXH5744M Image
Restricted Sales for Services

TSXH5744M

Schneider Electric TSXH5744M Image
Restricted Sales for Services
TSXH5744M

Unity hot standby processor - 1 racks(6/8/12 slots) - 4 com module processor

Show more characteristics
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

TSXH5744M is replaced by:
Product
Qty
BMEH584040
Qty
1
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4
  • Reason for Substitution: End of life
  • Substitution date: 31 December 2018
1
  • Main
    range of product
    Modicon Premium Automation platform
    product or component type
    Unity Hot Standby processor
    software designation
    Unity Pro
    Complementary
    number of racks
    1 6/8/12 slots
    number of slots
    6
    12
    8
    discrete I/O processor capacity
    2048 I/O
    analogue I/O processor capacity
    256 I/O
    number of application specific channel
    64
    number of process control channel
    20 up to 60 simple loops
    integrated connection type
    Non isolated serial link female mini DIN connector (RS485) (19.2 kbit/s)
    Ethernet TCP/IP RJ45 connector
    USB port USB type A connector (12 Mbit/s)
    port Ethernet
    10BASE-T/100BASE-TX
    communication module processor capacity
    4
    memory description
    Internal RAM (with PCMCIA card) 2048 kB program
    Internal RAM (with PCMCIA card) 440 kB data
    Internal RAM (without PCMCIA card) 440 kB program and data
    PCMCIA card 16384 kB additional data storage
    maximum size of object areas
    32464 %MWi internal words located internal data
    32760 %KWi constant words located internal data
    440 kB data exchanged via CPU Sync link
    8056 %Mi located internal bits
    Unlimited (DFB and EFB function blocks) unlocated internal data
    Unlimited (elementary and derived data) unlocated internal data
    application structure
    1 master task
    execution time per instruction
    0.039...0.057 µs Boolean without PCMCIA card
    0.048...0.057 µs Boolean with PCMCIA card
    0.054...0.073 µs word or fixed-point arithmetic with PCMCIA card
    0.054...0.073 µs word or fixed-point arithmetic without PCMCIA card
    0.055...0.063 µs floating points with PCMCIA card
    0.055...0.063 µs floating points without PCMCIA card
    number of instructions per ms
    11.4 Kinst/ms 65 % Boolean + 35 % fixed arithmetic with PCMCIA card
    11.4 Kinst/ms 65 % Boolean + 35 % fixed arithmetic without PCMCIA card
    15.75 Kinst/ms 100 % Boolean with PCMCIA card
    15.75 Kinst/ms 100 % Boolean without PCMCIA card
    system overhead
    1 ms for master task
    marking
    CE
    local signalling
    1 LED (green)Ethernet TCP/IP port ready (RUN):
    1 LED (green)processor running (RUN):
    1 LED (red)collision detection (COL):
    1 LED (red)Ethernet TCP/IP port fault (ERR):
    1 LED (red)I/O module or configuration fault (I/O):
    1 LED (red)processor or system fault (ERR):
    1 LED (yellow)activity on TER or AUX terminal port (TER):
    1 LED (yellow)Ethernet link diagnostics (STS):
    1 LED (yellow)reception activity (RX):
    1 LED (yellow)transmission activity (TX):
    current consumption
    1880 mA at 5 V DC
    module format
    Double
    net weight
    0.61 kg
    Environment
    standards
    CSA C22.2 No 213 Class I Division 2 Group B
    CSA C22.2 No 213 Class I Division 2 Group A
    CSA C22.2 No 213 Class I Division 2 Group C
    73/23/EEC
    IEC 61131-2
    92/31/EEC
    89/336/EEC
    CSA C22.2 No 142
    CSA C22.2 No 213 Class I Division 2 Group D
    UL 508
    93/68/EEC
    product certifications
    RINA
    BV
    DNV
    GL
    LR
    RMRS
    ABS
    ambient air temperature for operation
    0…60 °C
    ambient air temperature for storage
    -25…70 °C
    relative humidity
    10…95 % without condensation for operation
    5…95 % without condensation for storage
    operating altitude
    0...2000 m
    protective treatment
    TC
    IP degree of protection
    IP20
    pollution degree
    2
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages34
    • English14
    • Chinese4
    • French12
    • German4
    • Italian4
    • Spanish4
    User guide
    Format
    Size
    Date
    Add to My Documents
    Premium and Atrium using EcoStruxure™ Control Expert - Discrete I/O modules, User Manual (Version 10)
    Description
    This manual describes the hardware and software implementation of Discrete modules for Premium and Atrium PLCs.
    Size pdf
    Size 5 MB
    Date 12/1/18
    Description
    This manual describes the hardware and software implementation of Discrete modules for Premium and Atrium PLCs.
    EcoStruxure™ Control Expert - OS Loader, User Manual (Version 16)
    Description
    This documentation presents OS Loader software and describes the communication principle with a CPU or module that can be updated.
    Size pdf
    Size 683.6 KB
    Date 12/1/18
    Description
    This documentation presents OS Loader software and describes the communication principle with a CPU or module that can be updated.
    EcoStruxure™ Control Expert - Operating Modes (Version 22)
    Description
    This document describes programming a Modicon M340, Premium, Atrium or Quantum PLC using the IEC 61131-3 conforming programming languages Function Block Diagram (FBD), Ladder Diagram (LD), Sequential Function Chart (SFC), |Instruction List (IL) and Structured Text (ST).
    Size pdf
    Size 25.7 MB
    Date 12/1/18
    Description
    This document describes programming a Modicon M340, Premium, Atrium or Quantum PLC using the IEC 61131-3 conforming programming languages Function Block Diagram (FBD), Ladder Diagram (LD), Sequential Function Chart (SFC), |Instruction List (IL) and Structured Text (ST).
    Premium and Atrium using EcoStruxure™ Control Expert, Processors, Racks and Power Supply Modules (Version 10)
    Description
    This manual describes the hardware installation of the Premium and Atrium range of PLCs and their main accessories. It contains 6 parts: - General presentation of Premium and Atrium PLC stations, - TSX P57/TSX H57 Premium Processors, - TSX PCI 57 Atrium Processors, - TSX PSY Supply modules, - Process power supply modules, - Standard and extendable TSX RKY racks.
    Size pdf
    Size 3.6 MB
    Date 12/1/18
    Description
    This manual describes the hardware installation of the Premium and Atrium range of PLCs and their main accessories. It contains 6 parts: - General presentation of Premium and Atrium PLC stations, - TSX P57/TSX H57 Premium Processors, - TSX PCI 57 Atrium Processors, - TSX PSY Supply modules, - Process power supply modules, - Standard and extendable TSX RKY racks.
    Premium using EcoStruxure™ Control Expert- Hot Standby, User Manual (Version 13)
    Description
    This manual presents information necessary to configure and operate your Premium Hot Standby System consisting of the Premium Hot Standby processor (TSX H57 24M or TSX H57 44M) and the Control Expert software. It also discusses the implementation of redundant I/O consistent with the Hot Standby system, including Discrete, Analog, and Ethernet I/O using the TSX ETY 4103 / 5103 modules. Finally, this manual provides information regarding device communication using Modbus and other Premium Ethernet services, and places the Hot Standby in context of a larger distributed system involving HMI / SCADA and remote network devices.
    Size pdf
    Size 4.5 MB
    Date 12/1/18
    Description
    This manual presents information necessary to configure and operate your Premium Hot Standby System consisting of the Premium Hot Standby processor (TSX H57 24M or TSX H57 44M) and the Control Expert software. It also discusses the implementation of redundant I/O consistent with the Hot Standby system, including Discrete, Analog, and Ethernet I/O using the TSX ETY 4103 / 5103 modules. Finally, this manual provides information regarding device communication using Modbus and other Premium Ethernet services, and places the Hot Standby in context of a larger distributed system involving HMI / SCADA and remote network devices.
    EcoStruxure™ Control Expert - OSLoader, 用户手册 (Version 11)
    Description
    本文档介绍 OS Loader 软件,同时还介绍了与可更新的 CPU 或模块通讯的通讯原理。
    Size pdf
    Size 832.7 KB
    Date 12/1/18
    Description
    本文档介绍 OS Loader 软件,同时还介绍了与可更新的 CPU 或模块通讯的通讯原理。
    EcoStruxure™ Control Expert - 操作模式 (Version 19)
    Description
    本文档描述如何使用符合 IEC 61131-3 标准的编程语言 - 功能块图 (FBD)、梯形图 (LD)、顺序功能图 (SFC)、指令列表 (IL) 和结构化文本 (ST) - 对 Modicon M340、Premium、Atrium 或Quantum PLC 进行编程。
    Size pdf
    Size 24.8 MB
    Date 12/1/18
    Description
    本文档描述如何使用符合 IEC 61131-3 标准的编程语言 - 功能块图 (FBD)、梯形图 (LD)、顺序功能图 (SFC)、指令列表 (IL) 和结构化文本 (ST) - 对 Modicon M340、Premium、Atrium 或Quantum PLC 进行编程。
    使用 EcoStruxure™ Control Expert 的 Premium 和 Atrium 处理器、机架和电源模块 , 实施手册 (Version 07)
    Description
    此手册描述了 PLC 的 Premium 和 Atrium 系列及其主要附件的硬件安装。
    Size pdf
    Size 3.5 MB
    Date 12/1/18
    Description
    此手册描述了 PLC 的 Premium 和 Atrium 系列及其主要附件的硬件安装。
    使用 EcoStruxure™ Control Expert 的 Premium - Hot Standby, 用户手册 (Version 11)
    Description
    本手册说明配置和操作 Premium 热备系统(包含 Premium 热备处理器(TSX H57 24M 或 TSXH57 44M)以及 Unity Pro 软件)的必要信息。还论述了实施与热备系统一致的冗余 I/O 的过程,包括使用 TSX ETY 4103 / 5103 模块的离散量、模拟量和以太网 I/O。最后,本手册提供有关使用Modbus 和其他 Premium 以太网服务进行设备通信以及将热备系统置于包含 HMI / SCADA 和远程网络设备的大型分布式系统环境中的信息。本手册介绍如何设置和配置已安装的 Premium 热备系统,而没有介绍 Premium 热备系统 CPU、机架、电源或关联硬件的基本物理安装。本手册没有提供如操作限制、接地、电磁兼容性或其他环境注意事项等的相关信息。有关这些主题的详细信息,请参阅相关文档 ( 参见第9 页)。
    Size pdf
    Size 4.2 MB
    Date 12/1/18
    Description
    本手册说明配置和操作 Premium 热备系统(包含 Premium 热备处理器(TSX H57 24M 或 TSXH57 44M)以及 Unity Pro 软件)的必要信息。还论述了实施与热备系统一致的冗余 I/O 的过程,包括使用 TSX ETY 4103 / 5103 模块的离散量、模拟量和以太网 I/O。最后,本手册提供有关使用Modbus 和其他 Premium 以太网服务进行设备通信以及将热备系统置于包含 HMI / SCADA 和远程网络设备的大型分布式系统环境中的信息。本手册介绍如何设置和配置已安装的 Premium 热备系统,而没有介绍 Premium 热备系统 CPU、机架、电源或关联硬件的基本物理安装。本手册没有提供如操作限制、接地、电磁兼容性或其他环境注意事项等的相关信息。有关这些主题的详细信息,请参阅相关文档 ( 参见第9 页)。
    Premium et Atrium sous EcoStruxure™ Control Expert, Processeurs, racks et modules d'alimentation, Manuel de mise en oeuvre (Version 10)
    Description
    Ce manuel décrit la mise en oeuvre matérielle des automates Premium et Atrium et de leurs accessoires principaux.
    Size pdf
    Size 3.7 MB
    Date 12/1/18
    Description
    Ce manuel décrit la mise en oeuvre matérielle des automates Premium et Atrium et de leurs accessoires principaux.
    Premium sous EcoStruxure™ Control Expert - Hot Standby, Guide utilisateur (Version 13)
    Description
    Ce manuel présente des informations nécessaires à la configuration et au fonctionnement de votre système de redondance d’UC Premium comprenant un processeur correspondant (TSX H57 24M ou TSX H57 44M) ainsi que le logiciel Unity Pro. Il décrit également la mise en oeuvre des E/S redondantes compatibles avec lesystème de redondance d’UC, y compris les E/S TOR, analogiques et Ethernet utilisant les modules TSX ETY 4103 / 5103. Finalement, ce manuel propose des informations sur la communication des équipements utilisant les services Ethernet Modbus et Premium, et intègre l’automate redondant dans un système distribué plusimportant, comprenant des équipements IHM/SCADA et des équipements de réseau distants.
    Size pdf
    Size 4.3 MB
    Date 12/1/18
    Description
    Ce manuel présente des informations nécessaires à la configuration et au fonctionnement de votre système de redondance d’UC Premium comprenant un processeur correspondant (TSX H57 24M ou TSX H57 44M) ainsi que le logiciel Unity Pro. Il décrit également la mise en oeuvre des E/S redondantes compatibles avec lesystème de redondance d’UC, y compris les E/S TOR, analogiques et Ethernet utilisant les modules TSX ETY 4103 / 5103. Finalement, ce manuel propose des informations sur la communication des équipements utilisant les services Ethernet Modbus et Premium, et intègre l’automate redondant dans un système distribué plusimportant, comprenant des équipements IHM/SCADA et des équipements de réseau distants.
    EcoStruxure™ Control Expert - OS Loader, Manuel utilisateur (Version 16)
    Description
    Cette documentation présente le logiciel OS Loader et décrit le principe de communication avec un processeur (CPU) ou un module qui peut être mis à jour.
    Size pdf
    Size 754.2 KB
    Date 12/1/18
    Description
    Cette documentation présente le logiciel OS Loader et décrit le principe de communication avec un processeur (CPU) ou un module qui peut être mis à jour.
    EcoStruxure™ Control Expert - Modes de fonctionnement (Version 22)
    Description
    Ce document décrit le processus de programmation d'un automate Modicon M340, Premium, Atrium ou Quantum à l'aide des langages de programmation conformes à la norme CEI 61131-3 : langage à blocs fonction (FBD), langage à contacts (LD), diagramme fonctionnel en séquence (SFC), liste d'instructions (IL) et littéral structuré (ST).
    Size pdf
    Size 27.9 MB
    Date 12/1/18
    Description
    Ce document décrit le processus de programmation d'un automate Modicon M340, Premium, Atrium ou Quantum à l'aide des langages de programmation conformes à la norme CEI 61131-3 : langage à blocs fonction (FBD), langage à contacts (LD), diagramme fonctionnel en séquence (SFC), liste d'instructions (IL) et littéral structuré (ST).
    Premium und Atrium unter EcoStruxure™ Control Expert, Prozessoren, Racks und Stromversorgungsgeräte Installationshandbuch (Version 12)
    Description
    In diesem Handbuch ist die Installation der Premium- und Atrium-Steuerungen sowie ihrem wichtigsten Zubehör beschrieben
    Size pdf
    Size 3.7 MB
    Date 12/1/18
    Description
    In diesem Handbuch ist die Installation der Premium- und Atrium-Steuerungen sowie ihrem wichtigsten Zubehör beschrieben
    Premium mit EcoStruxure™ Control Expert - Hot Standby, Benutzerhandbuch (Version 13)
    Description
    Dieses Handbuch enthält die notwendigen Informationen für das Konfigurieren und Bedienen Ihres Premium Hot Standby-Systems, bestehend aus dem Premium Hot Standby-Prozessor (TSX H57 24M oder TSX H57 44M) und der Software Unity Pro. Es behandelt außerdem die Implementierung redundanter Ein-/Ausgänge inÜbereinstimmung mit dem Hot Standby-System, einschließlich digitaler, analoger und Ethernet-E/As, die die Module TSX ETY 4103 / 5103 verwenden. Des Weiteren bietet das Handbuch auch Informationen bezüglich der Gerätekommunikation bei Verwendung von Modbus und anderen Premium-Ethernetdiensten und erläutertdas Hot Standby-System in Verbindung mit größeren verteilten Systemen einschließlich HMI / SCADA und dezentralen Netzwerkgeräten.
    Size pdf
    Size 4.8 MB
    Date 12/1/18
    Description
    Dieses Handbuch enthält die notwendigen Informationen für das Konfigurieren und Bedienen Ihres Premium Hot Standby-Systems, bestehend aus dem Premium Hot Standby-Prozessor (TSX H57 24M oder TSX H57 44M) und der Software Unity Pro. Es behandelt außerdem die Implementierung redundanter Ein-/Ausgänge inÜbereinstimmung mit dem Hot Standby-System, einschließlich digitaler, analoger und Ethernet-E/As, die die Module TSX ETY 4103 / 5103 verwenden. Des Weiteren bietet das Handbuch auch Informationen bezüglich der Gerätekommunikation bei Verwendung von Modbus und anderen Premium-Ethernetdiensten und erläutertdas Hot Standby-System in Verbindung mit größeren verteilten Systemen einschließlich HMI / SCADA und dezentralen Netzwerkgeräten.
    EcoStruxure™ Control Expert - Betriebsarten (Version 22)
    Description
    Dieses Dokument beschreibt die Programmierung einer Modicon M340-, Premium-, Atrium- oder Quantum-SPS mittels der IEC 61131-3-konformen Programmiersprachen Funktionsbausteindiagramm (FBD), Kontaktplan (LD), Ablaufplan (SFC), Anweisungsliste (IL) und Strukturierter Text (ST).
    Size pdf
    Size 26.9 MB
    Date 12/1/18
    Description
    Dieses Dokument beschreibt die Programmierung einer Modicon M340-, Premium-, Atrium- oder Quantum-SPS mittels der IEC 61131-3-konformen Programmiersprachen Funktionsbausteindiagramm (FBD), Kontaktplan (LD), Ablaufplan (SFC), Anweisungsliste (IL) und Strukturierter Text (ST).
    EcoStruxure™ Control Expert - OS Loader, Benutzerhandbuch (Version 16)
    Description
    In dieser Dokumentation wird die Software OS Loader vorgestellt und das Prinzip der Kommunikation mit einer CPU bzw. mit einem Modul beschrieben, die bzw. das aktualisiert werden kann.
    Size pdf
    Size 758.1 KB
    Date 12/1/18
    Description
    In dieser Dokumentation wird die Software OS Loader vorgestellt und das Prinzip der Kommunikation mit einer CPU bzw. mit einem Modul beschrieben, die bzw. das aktualisiert werden kann.
    Premium e Atrium con EcoStruxure™ Control Expert, Processori, rack e moduli alimentatori, Manuale di implementazione (Version 07)
    Description
    Questo manuale descrive l'installazione hardware dei PLC della gamma Premium e Atrium, nonché dei relativi principali accessori.
    Size pdf
    Size 3.6 MB
    Date 12/1/18
    Description
    Questo manuale descrive l'installazione hardware dei PLC della gamma Premium e Atrium, nonché dei relativi principali accessori.
    Premium con EcoStruxure™ Control Expert - Hot Standby, Manuale utente (Version 13)
    Description
    Questo manuale illustra le informazioni necessarie per configurare e far funzionare il sistema Premium Hot Standby costituito dal processore Premium Hot Standby (TSX H57 24M o TSX H57 44M) e dal software Unity Pro. Illustra, inoltre l’implementazione di I/O ridondanti coerenti con il sistema Hot Standby, inclusi I/O digitali,analogici ed Ethernet che utilizzano i moduli TSX ETY 4103 / 5103. Infine, questo manuale fornisce informazioni sulla comunicazione fra dispositivi che utilizzano Modbus e altri servizi Ethernet Premium e posiziona un sistema Hot Standby nel contesto di un più ampio sistema distribuito che si avvale di interfacce HMI / SCADA e di dispositivi di rete remoti.
    Size pdf
    Size 4.3 MB
    Date 12/1/18
    Description
    Questo manuale illustra le informazioni necessarie per configurare e far funzionare il sistema Premium Hot Standby costituito dal processore Premium Hot Standby (TSX H57 24M o TSX H57 44M) e dal software Unity Pro. Illustra, inoltre l’implementazione di I/O ridondanti coerenti con il sistema Hot Standby, inclusi I/O digitali,analogici ed Ethernet che utilizzano i moduli TSX ETY 4103 / 5103. Infine, questo manuale fornisce informazioni sulla comunicazione fra dispositivi che utilizzano Modbus e altri servizi Ethernet Premium e posiziona un sistema Hot Standby nel contesto di un più ampio sistema distribuito che si avvale di interfacce HMI / SCADA e di dispositivi di rete remoti.
    EcoStruxure™ Control Expert - OSLoader, Manuale utente (Version 16)
    Description
    Questa documentazione presenta il software OS Loader e descrive il principio di comunicazione con una CPU o un modulo che è possibile aggiornare.
    Size pdf
    Size 738.5 KB
    Date 12/1/18
    Description
    Questa documentazione presenta il software OS Loader e descrive il principio di comunicazione con una CPU o un modulo che è possibile aggiornare.
    EcoStruxure™ Control Expert - Modalità operative (Version 22)
    Description
    Questo documento descrive la programmazione di un PLC Modicon M340,Premium, Atrium o Quantum mediante i linguaggi di programmazione Diagramma di blocco funzione (FBD), Diagramma Ladder (LD), Grafico di funzione sequenziale (SFC), Elenco istruzioni (IL) e Testo strutturato (ST), in conformità con IEC 61131-3.
    Size pdf
    Size 27.1 MB
    Date 12/1/18
    Description
    Questo documento descrive la programmazione di un PLC Modicon M340,Premium, Atrium o Quantum mediante i linguaggi di programmazione Diagramma di blocco funzione (FBD), Diagramma Ladder (LD), Grafico di funzione sequenziale (SFC), Elenco istruzioni (IL) e Testo strutturato (ST), in conformità con IEC 61131-3.
    Premium y Atrium con EcoStruxure™ Control Expert, Procesadores, bastidores y módulo de fuente de alimentación, Manual de instalación (Version 12)
    Description
    En este manual se describe la instalación del hardware de las gamas Premium y Atrium de PLC y sus principales accesorios
    Size pdf
    Size 3.7 MB
    Date 12/1/18
    Description
    En este manual se describe la instalación del hardware de las gamas Premium y Atrium de PLC y sus principales accesorios
    Premium con EcoStruxure™ Control Expert - Hot Standby, Manual del usuario (Version 13)
    Description
    Este manual contiene la información necesaria para configurar y operar su sistema Premium Hot Standby, que consiste del procesador Premium Hot Standby (TSX H57 24M o TSX H57 44M) y el software Unity Pro. También aborda la implementación de E/S redundantes de acuerdo con el sistema Hot Standby, incluidas las E/Sdigitales, analógicas y de Ethernet que usan los módulos TSX ETY 4103/5103. Finalmente, este manual ofrece información sobre la comunicación de dispositivos que usan Modbus y otros servicios Ethernet Premium, y sitúa a Hot Standby en el contexto de un sistema distribuido más amplio que relaciona HMI/SCADA y otrosdispositivos de red remotos.
    Size pdf
    Size 4.3 MB
    Date 12/1/18
    Description
    Este manual contiene la información necesaria para configurar y operar su sistema Premium Hot Standby, que consiste del procesador Premium Hot Standby (TSX H57 24M o TSX H57 44M) y el software Unity Pro. También aborda la implementación de E/S redundantes de acuerdo con el sistema Hot Standby, incluidas las E/Sdigitales, analógicas y de Ethernet que usan los módulos TSX ETY 4103/5103. Finalmente, este manual ofrece información sobre la comunicación de dispositivos que usan Modbus y otros servicios Ethernet Premium, y sitúa a Hot Standby en el contexto de un sistema distribuido más amplio que relaciona HMI/SCADA y otrosdispositivos de red remotos.
    EcoStruxure™ Control Expert - OS Loader, Manual de usuario (Version 16)
    Description
    En este documento se presenta el software OS Loader y se describen los principios de comunicación con una CPU o módulo que pueden ser actualizados.
    Size pdf
    Size 741.7 KB
    Date 12/1/18
    Description
    En este documento se presenta el software OS Loader y se describen los principios de comunicación con una CPU o módulo que pueden ser actualizados.
    EcoStruxure™ Control Expert - Modalidades de funcionamiento (Version 22)
    Description
    En este documento se describe la programación de un PLC Modicon M340,Premium, Atrium o Quantum con los lenguajes de programación de diagrama de bloques de funciones (FBD, Function Block Diagram), diagrama de Ladder (LD), gráfica de función secuencial (SFC, Sequential Function Chart), lista de instrucciones (IL, Instruction List) y texto estructurado (ST, Structured Text) según la norma IEC 61131-3.
    Size pdf
    Size 27.3 MB
    Date 12/1/18
    Description
    En este documento se describe la programación de un PLC Modicon M340,Premium, Atrium o Quantum con los lenguajes de programación de diagrama de bloques de funciones (FBD, Function Block Diagram), diagrama de Ladder (LD), gráfica de función secuencial (SFC, Sequential Function Chart), lista de instrucciones (IL, Instruction List) y texto estructurado (ST, Structured Text) según la norma IEC 61131-3.
    Certificate
    Format
    Size
    Date
    Add to My Documents
    CSA_225844_1041715_PREMIUM (Version 1.0)
    Description
    CSA for ordinary locations and hazardous locations
    Size PDF
    Size 159.3 KB
    Date 8/16/19
    Description
    CSA for ordinary locations and hazardous locations
    EAC_RUCFRME83B00163_PREMIUM_NOV2014 (Version 1.0)
    Description
    Eurasian Conformity
    Size pdf
    Size 1.8 MB
    Date 11/26/14
    Description
    Eurasian Conformity
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    DCC_PREMIUM_JUL2016 (Version 1.0)
    Description
    Manufacturer's Declaration of Conformity
    Size pdf
    Size 478.2 KB
    Date 7/20/16
    Description
    Manufacturer's Declaration of Conformity
    ACMA_RCM_PREMIUM_FEB2015 (Version 1.0)
    Description
    Australian Communications and Media Authority (ACMA)
    Size pdf
    Size 1.9 MB
    Date 2/10/15
    Description
    Australian Communications and Media Authority (ACMA)
    Marine certificate
    Format
    Size
    Date
    Add to My Documents
    MERCHANT_NAVY_PLC_INSTALLATION (Version 1.0)
    Description
    Merchant navies Installation Instructions
    Size pdf
    Size 181.4 KB
    Date 1/11/19
    Description
    Merchant navies Installation Instructions
    RMRS_16.00045.272_PREMIUM_DEC2016 (Version 1.0)
    Description
    Russian Maritime Register of Shipping
    Size pdf
    Size 1.6 MB
    Date 12/29/16
    Description
    Russian Maritime Register of Shipping
    DNV-GL Marine Certificate PREMIUM PLCs (Version 1.0)
    Description
    Det Norske Veritas
    Size pdf
    Size 164.4 KB
    Date 11/15/16
    Description
    Det Norske Veritas
    BV Marine Certificate PREMIUM PLCs (Version 1.0)
    Files in document
    Description
    Bureau Veritas
    Size zip
    Size 438.5 KB
    Date 8/17/16
    Files in document
    Description
    Bureau Veritas
    RINA_ELE104415CS_PREMIUM_APR2015 (Version 1.0)
    Description
    RINA Italian Marine
    Size pdf
    Size 750.3 KB
    Date 4/15/15
    Description
    RINA Italian Marine
  • View more View less

    Software and Firmware

    Language
    • English1
    Firmware - Updates
    Format
    Size
    Date
    Add to My Documents
    Premium_724_744_last firmware_history (Version 3.20)
    Description
    Please find the last firmware history of those CPUs.
    Size pdf
    Size 29.7 KB
    Date 12/3/19
    Description
    Please find the last firmware history of those CPUs.
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.