  • Main
    range
    TeSys
    product name
    TeSys VARIO
    device short name
    VCF
    product or component type
    Emergency stop switch disconnector
    performance level
    High performance
    poles description
    3P
    contacts type and composition
    3 NO
    network type
    DC
    AC
    control type
    Rotary handle
    rotary handle mounting style
    Direct
    handle colour
    Red
    handle front plate colour
    Yellow
    suitability for isolation
    Yes
    Complementary
    rotary handle padlocking
    1 to 3 padlocks 4…8 mm
    marking
    0 - 1
    mounting support
    Handle: door
    Switch: door
    fixing mode
    By 4 screws for handle
    [Ue] rated operational voltage
    690 V AC 50/60 Hz
    [Uimp] rated impulse withstand voltage
    8 kV
    [Ith] conventional free air thermal current
    80 A
    [Ithe] conventional enclosed thermal current
    63 A
    [Ie] rated operational current
    57 A AC-23 Ue: 400 V
    rated operational power in W
    18.5 kW at 690 V (AC-3)
    15 kW at 230...240 V (AC-3)
    22 kW at 400...415 V (AC-3)
    30 kW at 500 V (AC-3)
    30 kW at 690 V (AC-23A)
    37 kW at 500 V (AC-23A)
    18.5 kW at 230...240 V (AC-23A)
    30 kW at 400...415 V (AC-23A)
    intermittent duty class
    30
    Making capacity ( I Rms)
    800 A at 400 V AC-21A
    800 A at 400 V AC-22A
    800 A at 400 V AC-23A
    [Icm] rated short-circuit making capacity
    2.1 kA at 400 V at Ipeak
    [Icw] rated short-time withstand Rms current
    960 A at 400 V duration: 1 s
    rated conditional short-circuit current
    10 kA at 400 V - associated fuse 80 A aM
    10 kA at 400 V - associated fuse 80 A gG
    breaking capacity
    640 A at 400 V (AC-21A)
    640 A at 400 V (AC-22A)
    640 A at 400 V (AC-23A)
    device composition
    Switch
    Handle
    mechanical durability
    30000 cycles
    electrical durability
    30000 cycles AC-21
    30000 cycles DC-1...5
    connections - terminals
    Power circuit: screw clamp terminals25 mm² - solid
    Power circuit: screw clamp terminals16 mm² - flexible - with cable end
    tightening torque
    Power circuit: 4 N.m - on screw clamp terminals
    handle front plate dimension
    60 x 60 mm
    height
    83 mm
    width
    60 mm
    net weight
    0.56 kg
    Environment
    standards
    IEC 60947-3
    product certifications
    CCC
    GL
    UL
    CSA
    protective treatment
    TC
    IP degree of protection
    IP20 conforming to IEC 60529
    IP65
    mechanical robustness
    Vibrations 10...150 Hz (1 gn) conforming to IEC 60068-2-6
    Shocks 11 ms (30 Gn) conforming to IEC 60068-2-27
    ambient air temperature for operation
    -20…50 °C
    fire resistance
    960 °C conforming to IEC 60695-2-1
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    REACh free of SVHC
    Yes
    EU RoHS Directive
    Toxic heavy metal free
    Yes
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
     Pro-active China RoHS declaration (out of China RoHS legal scope)
    Environmental Disclosure
    Circularity Profile
    No need of specific recycling operations
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages11
    • English9
    • French5
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    Tesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)
    Description
    Ready-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.
    Size pdf
    Size 111.5 MB
    Date 7/12/19
    Description
    Ready-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.
    TeSys catalogue - 2019 - chapter B3 Switch-disconnectors Vario mini-Vario (Version 6.0)
    Description
    Rotary switch-disconnectors Vario , mini-Vario and accessories
    Size pdf
    Size 3.1 MB
    Date 5/15/19
    Description
    Rotary switch-disconnectors Vario , mini-Vario and accessories
    Catalogue TeSys 2019 - Composants pour protection et commande de moteurs (Version 7.1)
    Description
    Le catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.
    Size pdf
    Size 108.2 MB
    Date 7/12/19
    Description
    Le catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.
    Catalogue TeSys 2019 - chapitre B3 - Interrupteurs-sectionneurs Vario mini-Vario (Version 4.0)
    Description
    Présentation des interrupteurs-sectionneurs rotatifs 12 à 175 A
    Size pdf
    Size 4.4 MB
    Date 6/11/19
    Description
    Présentation des interrupteurs-sectionneurs rotatifs 12 à 175 A
    CAD
    Format
    Size
    Date
    Add to My Documents
    Size zip
    Size 827.6 KB
    Date 4/7/16
    Files in document
    pdf
    291.5 KB
    stp
    536.1 KB
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 2.2 MB
    Date 4/10/06
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 277.1 KB
    Date 7/4/19
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    TeSys Vario - emergency stop switch disconnector - 80 A - on door
    Description
    TeSys Vario - emergency stop switch disconnector - 80 A - on door
    Size pdf
    Size 195.3 KB
    Date 11/22/19
    Description
    TeSys Vario - emergency stop switch disconnector - 80 A - on door
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 416.1 KB
    Date 6/21/11
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    TeSys Vario - emergency stop switch disconnector - 80 A - on door
    Description
    TeSys Vario - emergency stop switch disconnector - 80 A - on door
    Size pdf
    Size 195.3 KB
    Date 11/22/19
    Description
    TeSys Vario - emergency stop switch disconnector - 80 A - on door
    RoHs China Declaration
    Format
    Size
    Date
    Add to My Documents
    TeSys Vario - emergency stop switch disconnector - 80 A - on door
    Description
    TeSys Vario - emergency stop switch disconnector - 80 A - on door
    Size pdf
    Size 195.3 KB
    Date 11/22/19
    Description
    TeSys Vario - emergency stop switch disconnector - 80 A - on door
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /