Show more characteristics
Commercial status
Discontinued on
14 November 2014
End-of-service on
14 November 2014
has not been replaced. Please contact your customer care center for more information.
-
Characteristics
Main range of product Harmony XALDproduct or component type Complete control stationdevice short name XALDproduct destination For XB5 Ø 22 mm control and signalling unitscontrol station application Stop functioncolour of base of enclosure Light grey (RAL 7035)colour of cover Dark grey (RAL 7016)material Polycarbonateoperator profile 1 mushroom head push-buttonoperators description Red ''ARRET'' 1 NCcontrol station composition 1 mushroom head Ø 40 mm push-button, red 1 NC ARRET markingmarking location Marking on legend holdercontact operation Slow-breakComplementary cable entry 1 knock-out for cable entry, clamping capacity: 14 mm2 knock-outs for Pg 13 cable gland and ISO M20, clamping capacity: 12 mmnet weight 0.182 kgresistance to high pressure washer 7000000 Pa at 55 °C, distance : 0.1 mpositive opening With conforming to EN/IEC 60947-5-1 appendix Koperating travel 1.5 mm (NC changing electrical state)4.3 mm (total travel)operating force 3.5 N NC changing electrical statemechanical durability 5000000 cyclesconnections - terminals Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN/IEC 60947-1tightening torque 0.8…1.2 N.m conforming to EN/IEC 60947-1shape of screw head Cross compatible with Philips no 1 screwdriverCross compatible with pozidriv No 1 screwdriverSlotted compatible with flat Ø 4 mm screwdriverSlotted compatible with flat Ø 5.5 mm screwdrivercontacts material Silver alloy (Ag/Ni)short-circuit protection 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1[Ith] conventional free air thermal current 10 A conforming to EN/IEC 60947-5-1[Ui] rated insulation voltage 600 V (pollution degree 3) conforming to EN/IEC 60947-1[Uimp] rated impulse withstand voltage 6 kV EN/IEC 60947-1[Ie] rated operational current 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-13 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-11.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-10.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-10.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-10.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1electrical durability 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix Celectrical reliability Λ < 10exp(-6) at 5 V and 1 mA conforming to EN/IEC 60947-5-4Λ < 10exp(-8) at 17 V and 5 mA conforming to EN/IEC 60947-5-4Environment protective treatment THambient air temperature for storage -40…70 °Cambient air temperature for operation -40…70 °Covervoltage category Class II conforming to IEC 60536IP degree of protection IP66 conforming to IEC 60529IP69IP69KNEMA degree of protection NEMA 13NEMA 4XIK degree of protection IK03 conforming to EN 50102standards EN/IEC 60947-5-4JIS C8201-5-1EN/IEC 60947-1UL 508EN/IEC 60947-5-1CSA C22.2 No 14EN/IEC 60947-5-5JIS C8201-1product certifications CSAUL listedvibration resistance 5 gn (f= 12…500 Hz) conforming to IEC 60068-2-6shock resistance 10 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 -
View more
Documents
Language- English4
CertificateFormatSizeAdd to My DocumentsXAC, XAL, XAPS, XAW Control Stations (Version 1.0)DescriptionGOST CertificateSize PDFSize 897 KBDate 2/6/15DescriptionGOST CertificateXACA Pendant control station and XALD, XALK Control stations (Version 1.0)DescriptionUL CertificateSize htmlSize 300 BDate 5/16/13DescriptionUL CertificateXALD, XALK Control stations (Version 1.0)DescriptionCSA CertificateSize pdfSize 106.7 KBDate 3/11/08DescriptionCSA CertificateProduct Environmental ProfileFormatSizeAdd to My DocumentsSize pdfSize 894.3 KBDate 11/1/11 -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
Dimensions(1)2 knock-outs for Pg 13.5 cable gland, maximum capacity 12 mm/0.47 in.(2)Knock-out for cable entry, maximum capacity 14 mm/0.55 in.Control station fitted with:
c in mm
c in in.
Flush pushbutton
62
2.44
Pilot light
64
2.52
Illuminated pushbutton
65.5
2.58
Projecting pushbutton
66
2.60
Selector switch
80
3.15
Mushroom head pushbutton
91.5
3.58
Latching mushroom head Emergency stop pushbutton wit h key
115
4.53
Key switch
105.5
4.15