View all
Harmony XAC

XESD2251
XESD2251
spring return contact block - 3 NO + 1 NO - front mounting, 40 mm centres
Show more characteristics-
Characteristics
Main range of product Harmony XACproduct or component type Contact blockcomponent name XENDelectrical circuit type Power circuitcontact block application Single speedcontact block type Doubletype of operator 2 spring returnproduct compatibility XACBmechanical interlocking With mechanical interlockingcontacts type and composition 3 NO + 1 NOmounting of block Front mountingcontact operation Snap actionStaggeredComplementary connections - terminals Screw clamp terminals, 1 x 2.5 mm² with or without cable endScrew clamp terminals, 2 x 1.5 mm² with or without cable endhorizontal fixing centres 40 mmmechanical durability 1000000 cycles[Ithe] conventional enclosed thermal current 20 A[Ui] rated insulation voltage 300 V conforming to CSA[Uimp] rated impulse withstand voltage IEC 60947-1 6 kVoperating force 32 Nshort-circuit protection 12 A fuse protection by cartridge fuse type aMrated operational power in W 31 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C35 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C48 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix Crated operational power in VA 140 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 24 V 50/60 Hz, load factor = 0.5 (inductive load)210 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 48 V 50/60 Hz, load factor = 0.5 (inductive load)640 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 127 V 50/60 Hz, load factor = 0.5 (inductive load)680 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 230 V 50/60 Hz, load factor = 0.5 (inductive load)electrical durability 1000000 cycles AC-3, 3000 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A1000000 cycles AC-4, 3000 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A700000 cycles AC-3, 3000 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A700000 cycles AC-4, 3000 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix Aterminal identifier (11-12)NC(13-14)NOnet weight 0.21 kgEnvironment standards IEC 60947-3CSA C22.2 No 14EN 60947-3ambient air temperature for operation -25…70 °Cambient air temperature for storage -40…70 °Cvibration resistance 15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6shock resistance 100 gn conforming to IEC 60068-2-27electrical shock protection class Class II conforming to IEC 61140Contractual warranty Warranty 18 months -
View more
Documents
Language- All Languages2
- English2
- Chinese1
CertificateFormatSizeAdd to My DocumentsXACB (Control circuit) Pendant control station (Version 1.0)DescriptionCCC CertificateSize pdfSize 6.2 MBDate 11/12/19DescriptionCCC CertificateCCC Certificate- XACB XESD XACS (Version 1.0)DescriptionCCC CertificateSize pdfSize 5.7 MBDate 11/12/19DescriptionCCC Certificate -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.