Welcome to the Schneider Electric corporate Website

Select your location

Welcome the the Schneider Electric French website. It looks like you are located in the United States, would you like to change your location?

Traduisez en francais
View all   Preventa XPS
Schneider Electric XPSAK331144P Image
To be discontinued

XPSAK331144P

Green premium brand logo
Schneider Electric XPSAK331144P Image
To be discontinued
XPSAK331144P
Green premium brand logo

module XPSAK - Emergency stop - 48 V AC

Show more characteristics
Commercial status
To be discontinued on 30 June 2021
End-of-service soon on 31 December 2023
The maximum number of products that can be compared is 4. Remove already added products.

XPSAK331144P is replaced by:
Product
Qty
XPSUAK32AP
Qty
1
The maximum number of products that can be compared is 4. Remove already added products.
  • Reason for Substitution: End of life
  • Substitution date: 01 June 2019
1
  • Main
    range of product
    Preventa Safety automation
    product or component type
    Preventa safety module
    safety module name
    XPSAK
    safety module application
    For emergency stop, switch, sensing mat/edges or safety light curtain monitoring
    function of module
    Proximity sensor monitoring
    Monitoring of a movable guard
    Monitoring of a movable guard associated with 2 switches and automatic start
    Multiple emergency stop monitoring 2-channel wiring
    Sensing mat and edges monitoring
    Emergency stop monitoring 1-channel wiring
    Monitoring of electro-sensitive protection equipment (ESPE)
    Emergency stop with 2 NC contacts monitoring 2-channel wiring
    safety level
    Can reach PL e/category 4 conforming to EN/ISO 13849-1
    Can reach SILCL 3 conforming to EN/IEC 62061
    safety reliability data
    DC > 99 % conforming to EN/ISO 13849-1
    MTTFd = 154.5 years conforming to EN/ISO 13849-1
    PFHd = 7.39E-9 1/h conforming to EN/IEC 62061
    type of start
    Configurable
    connections - terminals
    Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mm² flexible with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
    output type
    Relay instantaneous opening, 3 NO circuit(s), volt-free
    number of additional circuits
    1 NC + 4 solid state outputs
    [Us] rated supply voltage
    48 V AC - 15...10 %
    Complementary
    synchronisation time between inputs
    Unlimited (manual start)
    2 or 4 s depending of wiring (automatic start)
    supply frequency
    50/60 Hz
    maximum power consumption in VA
    6 VA AC
    input protection type
    Internal, electronic
    breaking capacity
    180 VA holding AC-15 C300 relay output
    1800 VA inrush AC-15 C300 relay output
    breaking capacity
    1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
    output thermal current
    6 A per relay for relay output
    [Ith] conventional free air thermal current
    18 A
    associated fuse rating
    4 A gG or gL for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
    6 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
    minimum output current
    10 mA for relay output
    minimum output voltage
    17 V for relay output
    maximum response time on input open
    40 ms
    [Ui] rated insulation voltage
    300 V (pollution degree 2) conforming to IEC 60947-5-1
    300 V (pollution degree 2) conforming to DIN VDE 0110 part 1
    [Uimp] rated impulse withstand voltage
    4 kV overvoltage category III conforming to IEC 60947-5-1
    4 kV overvoltage category III conforming to DIN VDE 0110 part 1
    local signalling
    4 LEDs
    mounting support
    35 mm symmetrical DIN rail
    net weight
    0.3 kg
    Environment
    standards
    EN/IEC 60947-5-1
    EN 1088/ISO 14119
    EN/ISO 13850
    EN/IEC 60204-1
    product certifications
    UL
    CSA
    TÜV
    IP degree of protection
    IP20 (terminals) conforming to EN/IEC 60529
    IP40 (enclosure) conforming to EN/IEC 60529
    ambient air temperature for operation
    -10…55 °C
    ambient air temperature for storage
    -25…85 °C
    Packing Units
    Package 1 Weight
    0.481 kg
    Package 1 Height
    1.050 dm
    Package 1 width
    1.250 dm
    Package 1 Length
    0.630 dm
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    PVC free
    Yes
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages13
    • English11
    • Chinese3
    • French4
    • German4
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    Certificate
    Format
    Size
    Date
    Add to My Documents
    CCC_2007010303245539_Certificate_XPSAC_valid_20200227 (Version 1.2)
    Description
    CCC certificate of XPSAC, XPSAF, XPSAFL, XPSAK, XPSAR, XPSAV, XPSBF, XPSCM, XPSDMB, XPSDME, XPSMP, XPSTSA, XPSTSW, XPSVC, XPSATE, XPSVNE
    prp.document.label.format pdf
    Size 4.5 MB
    Date 12/11/19
    Description
    CCC certificate of XPSAC, XPSAF, XPSAFL, XPSAK, XPSAR, XPSAV, XPSBF, XPSCM, XPSDMB, XPSDME, XPSMP, XPSTSA, XPSTSW, XPSVC, XPSATE, XPSVNE
    prp.document.label.format htm
    Size 202 B
    Date 7/1/10
    prp.document.label.format pdf
    Size 1.2 MB
    Date 3/23/18
    prp.document.label.format pdf
    Size 1.4 MB
    Date 3/1/10
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    XPSAK331144P : module XPSAK - Emergency stop - 48 V AC
    Description
    module XPSAK - Emergency stop - 48 V AC
    prp.document.label.format pdf
    Size 195.3 KB
    Date 8/4/20
    Description
    module XPSAK - Emergency stop - 48 V AC
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 541.3 KB
    Date 6/12/18
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 2.2 MB
    Date 5/1/18
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    XPSAK331144P : module XPSAK - Emergency stop - 48 V AC
    Description
    module XPSAK - Emergency stop - 48 V AC
    prp.document.label.format pdf
    Size 195.3 KB
    Date 8/4/20
    Description
    module XPSAK - Emergency stop - 48 V AC
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 2.2 MB
    Date 5/1/18
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions