Welcome to the Schneider Electric corporate Website

Select your location

View all   Preventa XPS Universal
Schneider Electric XPSUAB11CP Image

XPSUAB11CP

Green premium brand logo
Schneider Electric XPSUAB11CP Image
XPSUAB11CP
Green premium brand logo

Preventa module Cat.1 potential free NC/NC, NO/NC & PNP/PNP 24vac/dc screw

Show more characteristics
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range of product
    Preventa Safety automation
    product or component type
    Preventa safety module
    safety module name
    XPSUAB
    safety module application
    For electrical monitoring of two-hand control stations
    For application with safety switchover contact
    For emergency stop, guard and light curtain monitoring
    Monitoring antivalent contacts
    function of module
    Emergency stop monitoring 1-channel wiring
    Guard monitoring 1-channel wiring
    Monitoring 1 PNP sensor
    Monitoring two-hand control station type IIIA
    Magnetic switch monitoring
    Light curtain monitoring
    RFID switch
    Monitoring of electro-sensitive protection equipment (ESPE)
    Proximity sensor monitoring
    safety level
    Can reach PL c/category 1 conforming to ISO 13849-1
    Can reach SILCL 1 conforming to IEC 62061
    Can reach SIL 1 conforming to IEC 61508
    safety reliability data
    MTTFd >= 30 years conforming to ISO 13849-1
    Dcavg < 60 % conforming to ISO 13849-1
    PFHd = 1177E-09 1/h conforming to ISO 13849-1
    HFT = 0 conforming to IEC 62061
    PFHd = 1177E-09 1/h conforming to IEC 62061
    SFF > 60% conforming to IEC 62061
    HFT=0 conforming to IEC 61508-1
    PFHd = 1177E-09 1/h conforming to IEC 61508-1
    SFF > 60% conforming to IEC 61508-1
    Type = B conforming to IEC 61508-1
    electrical circuit type
    NC pair
    PNP pair
    Antivalent pair
    OSSD pair
    connections - terminals
    Removable screw terminal block, 0.2...2.5 mm² solid or flexible
    Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor
    Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor
    Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel
    Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
    [Us] rated supply voltage
    24 V AC - 15...10 %
    24 V DC - 20...20 %
    Complementary
    synchronisation time between inputs
    0.5 s
    2.2 s
    type of start
    Automatic/manual/monitored
    power consumption in W
    1.5 W 24 V DC
    power consumption in VA
    3.5 VA 24 V AC 50/60 Hz
    input protection type
    Internal, electronic
    safety outputs
    1 C/O
    safety inputs
    1 safety input 24 V DC 5 mA
    maximum line resistance
    60 Ohm
    input compatibility
    Normally closed circuit conforming to ISO 14119
    XC limit switch conforming to ISO 14119
    Mechanical contact conforming to ISO 14119
    Normally closed circuit conforming to ISO 13850
    Antivalent pair conforming to ISO 14119
    OSSD pair conforming to IEC 61496-1-2
    Two-hand control conforming to EN 574/ISO 13851-III A
    3-wire proximity sensors PNP
    output type
    Relay output : 250 V AC, AC-1, D300
    Relay output : 250 V AC, AC-15, D300
    Relay output : 24 V DC, DC-1, R300
    Relay output : 24 V DC, DC-13, R300
    [Ie] rated operational current
    5 A AC-1 for normally open relay contact
    3 A AC-15 for normally open relay contact
    5 A DC-1 for normally open relay contact
    3 A DC-13 for normally open relay contact
    3 A AC-1 for normally closed relay contact
    1 A AC-15 for normally closed relay contact
    2 A DC-1 for normally closed relay contact
    1 A DC-13 for normally closed relay contact
    Control Outputs
    2 on/off configurable pulsed output
    input/output type
    Semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related
    [Ith] conventional free air thermal current
    3 A
    associated fuse rating
    6 A gG for relay output conforming to IEC 60947-1
    minimum output current
    10 mA for relay output
    minimum output voltage
    15 V for relay output
    maximum response time on input open
    20 ms
    [Ui] rated insulation voltage
    250 V (pollution degree 2) conforming to EN/IEC 60947-1
    [Uimp] rated impulse withstand voltage
    4 kV overvoltage category II conforming to EN/IEC 60947-1
    local signalling
    LED (green)power ON:
    LED (red)error:
    LED (yellow)start:
    LED (yellow)safety status:
    LED (yellow)safety input S12:
    LED (yellow)safety input S13:
    mounting support
    35 mm symmetrical DIN rail
    depth
    120 mm
    ambient air temperature for operation
    -25…55 °C
    height
    100 mm
    width
    22.5 mm
    net weight
    0.200 kg
    Environment
    standards
    IEC 60947-5-1
    IEC 61508-1 functional safety standard
    IEC 61508-2 functional safety standard
    IEC 61508-3 functional safety standard
    IEC 61508-4 functional safety standard
    IEC 61508-5 functional safety standard
    IEC 61508-6 functional safety standard
    IEC 61508-7 functional safety standard
    ISO 13849-1 functional safety standard
    IEC 62061 functional safety standard
    product certifications
    TÜV
    CULus
    IP degree of protection
    IP20 (terminals) conforming to EN/IEC 60529
    IP40 (housing) conforming to EN/IEC 60529
    IP54 (mounting area) conforming to EN/IEC 60529
    relative humidity
    5…95 % non-condensing
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
  • View more View less

    Documents

    Language
    • All Languages20
    • English18
    • Chinese2
    • French2
    • German2
    • Italian1
    • Japanese1
    • Korean1
    • Portuguese1
    • Russian1
    • Spanish1
    • Turkish1
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 4.8 MB
    Date 3/2/20
    prp.document.label.format pdf
    Size 4.8 MB
    Date 3/2/20
    User guide
    Format
    Size
    Date
    Add to My Documents
    Preventa XPS Universal - XPSUAB Safety Module, User Guide (Version 00)
    Description
    This manual describes technical characteristics, installation, commissioning, operation andmaintenance of the safety module XPSUAB.
    prp.document.label.format pdf
    Size 1.4 MB
    Date 6/1/19
    Description
    This manual describes technical characteristics, installation, commissioning, operation andmaintenance of the safety module XPSUAB.
    PreventaSupport - Library Guide - for Preventa XPS Safety Modules (Version 00)
    Description
    This document describes the function blocks FB_PreventaDiag and FB_PreventaMain contained in the PreventaSupport library. FB_PreventaDiag can be used to evaluate the diagnostic output of Preventa XPS safety modules, thus monitoring the device functionality by "translating" the bit sequence into diagnostic code. FB_PreventaMain uses this diagnostic code as input and executes calculations concerning maintenance tasks based on the code.
    prp.document.label.format pdf
    Size 472 KB
    Date 4/1/19
    Description
    This document describes the function blocks FB_PreventaDiag and FB_PreventaMain contained in the PreventaSupport library. FB_PreventaDiag can be used to evaluate the diagnostic output of Preventa XPS safety modules, thus monitoring the device functionality by "translating" the bit sequence into diagnostic code. FB_PreventaMain uses this diagnostic code as input and executes calculations concerning maintenance tasks based on the code.
    PreventaSupport - Library Guide - for Preventa XPS Safety Modules (Version 00)
    Description
    This document describes the function blocks FB_PreventaDiag and FB_PreventaMain contained in the PreventaSupport library. FB_PreventaDiag can be used to evaluate the diagnostic output of Preventa XPS safety modules, thus monitoring the device functionality by "translating" the bit sequence into diagnostic code. FB_PreventaMain uses this diagnostic code as input and executes calculations concerning maintenance tasks based on the code.
    prp.document.label.format pdf
    Size 530 KB
    Date 3/1/19
    Description
    This document describes the function blocks FB_PreventaDiag and FB_PreventaMain contained in the PreventaSupport library. FB_PreventaDiag can be used to evaluate the diagnostic output of Preventa XPS safety modules, thus monitoring the device functionality by "translating" the bit sequence into diagnostic code. FB_PreventaMain uses this diagnostic code as input and executes calculations concerning maintenance tasks based on the code.
    prp.document.label.format pdf
    Size 1.5 MB
    Date 8/1/19
    Certificate
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 12 MB
    Date 9/23/19
    prp.document.label.format pdf
    Size 179.4 KB
    Date 6/11/19
    prp.document.label.format pdf
    Size 123.6 KB
    Date 3/21/19
    prp.document.label.format pdf
    Size 339.9 KB
    Date 2/12/19
    prp.document.label.format pdf
    Size 279.5 KB
    Date 1/4/19
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    Preventa XPS Universal - XPSUAB Safety Module, Instruction Sheet (Version 06)
    Description
    Safety modules, type XPSUAB, for monitoring Emergency stop, Antivalent contacts, Guard switch, Magnetic switch, Proximity safety switch, PNP sensor, RFID safety switch, Safety light curtain or Two-hand control stations
    prp.document.label.format pdf
    Size 4.7 MB
    Date 3/1/19
    Description
    Safety modules, type XPSUAB, for monitoring Emergency stop, Antivalent contacts, Guard switch, Magnetic switch, Proximity safety switch, PNP sensor, RFID safety switch, Safety light curtain or Two-hand control stations
    Preventa XPS Universal - XPSUAB Safety Module, Instruction Sheet (Version 06)
    Description
    Safety modules, type XPSUAB, for monitoring Emergency stop, Antivalent contacts, Guard switch, Magnetic switch, Proximity safety switch, PNP sensor, RFID safety switch, Safety light curtain or Two-hand control stations
    prp.document.label.format pdf
    Size 6.1 MB
    Date 3/1/19
    Description
    Safety modules, type XPSUAB, for monitoring Emergency stop, Antivalent contacts, Guard switch, Magnetic switch, Proximity safety switch, PNP sensor, RFID safety switch, Safety light curtain or Two-hand control stations
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    XPSUAB11CP : Preventa module Cat.1 potential free NC/NC, NO/NC & PNP/PNP 24vac/dc screw
    Description
    Preventa module Cat.1 potential free NC/NC, NO/NC & PNP/PNP 24vac/dc screw
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/31/20
    Description
    Preventa module Cat.1 potential free NC/NC, NO/NC & PNP/PNP 24vac/dc screw
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 244.5 KB
    Date 4/29/19
    prp.document.label.format pdf
    Size 170.6 KB
    Date 3/26/19
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 9 MB
    Date 2/1/19
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    XPSUAB11CP : Preventa module Cat.1 potential free NC/NC, NO/NC & PNP/PNP 24vac/dc screw
    Description
    Preventa module Cat.1 potential free NC/NC, NO/NC & PNP/PNP 24vac/dc screw
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/31/20
    Description
    Preventa module Cat.1 potential free NC/NC, NO/NC & PNP/PNP 24vac/dc screw
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 9 MB
    Date 2/1/19
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    XPSUAB11CP : Preventa module Cat.1 potential free NC/NC, NO/NC & PNP/PNP 24vac/dc screw
    Description
    Preventa module Cat.1 potential free NC/NC, NO/NC & PNP/PNP 24vac/dc screw
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/31/20
    Description
    Preventa module Cat.1 potential free NC/NC, NO/NC & PNP/PNP 24vac/dc screw
  • View more View less

    Software and Firmware

    Language
    • English1
    Software - Hotfix & Patch
    Format
    Size
    Date
    Add to My Documents
    Function Block file (Version V1.1)
    Files in document
    zip
    3 MB
    prp.document.label.format zip
    Size 7.9 MB
    Date 11/8/19
    Files in document
    zip
    3 MB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions
    Front and Side Views


    (A) :
    Product drawing
    (B) :
    Screw clamp terminal
    (C) :
    Side view
    (1) :
    Removable terminal blocks, top
    (2) :
    Removable terminal blocks, bottom
    (3) :
    LED indicators
    (4) :
    Start function selector
    (5) :
    Function selector
    (6) :
    Sealable transparent cover



  • Mounting and Clearance

    Mounting to DIN rail



    Screw-mounting



  • Connections and Schema

    Wiring Drawing


    (1) :
    A1-A2 (Power supply)
    (2) :
    S11-S12-S13 (Single-channel safety input)
    (3) :
    Y1-Y2 (Start)
    11-12-14 :
    Output
    B2 :
    Common ground terminal
    Z1 :
    Pulsed output for diagnostics, not safety-related