Welcome to the Schneider Electric corporate Website

Select your location

View all   Harmony eXLhoist
Schneider Electric ZARB18WM Image

ZARB18WM

Schneider Electric ZARB18WM Image
ZARB18WM

18 relay outputs wired connection – cable gland used in MBC (Tandem) application

Show more characteristics
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range of product
    Harmony XAR
    product or component type
    Base station
    device short name
    ZARB
    product specific application
    Hoisting applications
    Material handling
    Complementary
    cable entry
    Cable gland
    material
    PC (polycarbonate)
    [Us] rated supply voltage
    24...240 V AC/DC
    vibration resistance
    0.075 mm (f = 10…55 Hz)
    shock resistance
    15 gn 11 ms
    provided equipment
    Internal antenna
    nominal output current
    0.54 A at 48 V AC conforming to IEC 60947-5-1
    number of relays
    18
    relay type
    Motion relay outputs with 9 NO contact
    Auxiliary relay outputs with 7 NO contact
    Auxiliary relay outputs with 2 NC + 2 NO contact
    safety outputs
    2 NC relay outputs
    switching capacity in VA
    5 VA DC
    26 VA AC
    maximum switching current
    6.8 mA
    maximum switching voltage
    240 V AC/DC (+ 20 %)
    communication network type
    Wireless: bluetooth low energy
    transmission frequency
    2.4 GHz
    maximum sensing distance
    100 m in free field
    number of channels
    40
    fixing mode
    4 holes
    electrical durability
    100000 cycles
    mechanical durability
    1000000 cycles
    number of alarms
    6 programmable alarms
    number of inputs
    12
    service life
    10 year(s)
    width
    280 mm
    height
    305 mm
    depth
    100 mm
    net weight
    1.45 kg
    Environment
    IP degree of protection
    IP65
    NEMA degree of protection
    NEMA 4
    pollution degree
    3
    electromagnetic compatibility
    Resistance to electrostatic discharge - test level: 4 kV class B (on contact) conforming to IEC 61000-4-2
    Resistance to electrostatic discharge - test level: 8 kV class B (in air) conforming to IEC 61000-4-2
    Resistance to radiated electromagnetic fields - test level: 10 V/m class B conforming to IEC 61000-4-3
    standards
    IEC 61000-6-2
    radio agreement
    ICASA
    RSS
    ARIB
    FCC
    ANATEL
    SRRC
    relative humidity
    0…97 %
    ambient air temperature for operation
    -25…70 °C
    ambient air temperature for storage
    -40…70 °C
    product certifications
    UL
    CE
    CSA
    C-Tick
    EAC
    KC
    environmental characteristic
    RoHS compliant
    Offer Sustainability
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
  • View more View less

    Documents

    Language
    • All Languages8
    • English7
    • Chinese3
    • French4
    • German3
    • Italian3
    • Spanish3
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    Catalog of Harmony eXLhoist wireless industrial remote control - English 05/2020 (Version 5.0)
    Description
    Discover the catalog of Harmony eXLhoist wireless industrial remote control - English 05/2020
    prp.document.label.format pdf
    Size 5 MB
    Date 5/14/20
    Description
    Discover the catalog of Harmony eXLhoist wireless industrial remote control - English 05/2020
    prp.document.label.format pdf
    Size 4.2 MB
    Date 8/28/18
    User guide
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 8.4 MB
    Date 9/1/16
    Certificate
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 820 KB
    Date 10/1/18
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 3.4 MB
    Date 9/1/16
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    ZARB18WM : 18 relay outputs wired connection – cable gland used in MBC (Tandem) application
    Description
    18 relay outputs wired connection – cable gland used in MBC (Tandem) application
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/25/20
    Description
    18 relay outputs wired connection – cable gland used in MBC (Tandem) application
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    ZARB18WM : 18 relay outputs wired connection – cable gland used in MBC (Tandem) application
    Description
    18 relay outputs wired connection – cable gland used in MBC (Tandem) application
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/25/20
    Description
    18 relay outputs wired connection – cable gland used in MBC (Tandem) application
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    ZARB18WM : 18 relay outputs wired connection – cable gland used in MBC (Tandem) application
    Description
    18 relay outputs wired connection – cable gland used in MBC (Tandem) application
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/25/20
    Description
    18 relay outputs wired connection – cable gland used in MBC (Tandem) application
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions