Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

59715 Product picture Schneider Electric

View all Sepam series 80

Sepam series 80 - 59715

Modules and communication interfaces

59715 Product picture Schneider Electric
View all Sepam series 80

Sepam series 80 - 59715

Modules and communication interfaces

I/O module MES120 - Sepam series 60, 80 - 14 inputs+ 6 outputs 24...250V DC

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    module type
    Input/output module
    range of product
    Sepam series 80
    Sepam series 60
    device short name
    MES120
    Complementary
    input/output type
    14 inputs + 6 outputs 24...250 V DC
    logic input number
    14 : 24...250 V, limits: 19.2...275 V DC input current: 3 mA threshold tripping voltage: 14 V enhanced
    number of outputs
    1 control relay output(s)
    5 annunciation relay output(s)
    output type
    Annunciation relay : 100...240 V AC 47.5...63 Hz continuous current: 2 A breaking capacity: 0.001 kA cos φ > 0.3
    Annunciation relay : 127 V DC continuous current: 2 A breaking capacity: 0.0005 kA L/R < 20 ms
    Annunciation relay : 220 V DC continuous current: 2 A breaking capacity: 0.00015 kA L/R < 20 ms
    Annunciation relay : 24 V DC continuous current: 2 A breaking capacity: 0.002 kA L/R < 20 ms
    Annunciation relay : 250 V DC continuous current: 2 A breaking capacity: 0.0002 kA L/R < 20 ms
    Annunciation relay : 48 V DC continuous current: 2 A breaking capacity: 0.001 kA L/R < 20 ms
    Control relay : 100...240 V AC 47.5...63 Hz continuous current: 8 A breaking capacity: 0.005 kA cos φ > 0.3 making capacity: < 15 A for 200 ms
    Control relay : 100...240 V AC 47.5...63 Hz continuous current: 8 A breaking capacity: 0.008 kA resistive making capacity: < 15 A for 200 ms
    Control relay : 127 V DC continuous current: 8 A breaking capacity: 0.0002 kA L/R < 40 ms making capacity: < 15 A for 200 ms
    Control relay : 127 V DC continuous current: 8 A breaking capacity: 0.0005 kA L/R < 20 ms making capacity: < 15 A for 200 ms
    Control relay : 127 V DC continuous current: 8 A breaking capacity: 0.0007 kA resistive making capacity: < 15 A for 200 ms
    Control relay : 220 V DC continuous current: 8 A breaking capacity: 0.0001 kA L/R < 40 ms making capacity: < 15 A for 200 ms
    Control relay : 220 V DC continuous current: 8 A breaking capacity: 0.0002 kA L/R < 20 ms making capacity: < 15 A for 200 ms
    Control relay : 220 V DC continuous current: 8 A breaking capacity: 0.0003 kA resistive making capacity: < 15 A for 200 ms
    Control relay : 24 V DC continuous current: 8 A breaking capacity: 0.004 kA L/R < 40 ms making capacity: < 15 A for 200 ms
    Control relay : 24 V DC continuous current: 8 A breaking capacity: 0.006 kA L/R < 20 ms making capacity: < 15 A for 200 ms
    Control relay : 24 V DC continuous current: 8 A breaking capacity: 0.008 kA resistive making capacity: < 15 A for 200 ms
    Control relay : 250 V DC continuous current: 8 A breaking capacity: 0.0002 kA resistive making capacity: < 15 A for 200 ms
    Control relay : 48 V DC continuous current: 8 A breaking capacity: 0.001 kA L/R < 40 ms making capacity: < 15 A for 200 ms
    Control relay : 48 V DC continuous current: 8 A breaking capacity: 0.002 kA L/R < 20 ms making capacity: < 15 A for 200 ms
    Control relay : 48 V DC continuous current: 8 A breaking capacity: 0.004 kA resistive making capacity: < 15 A for 200 ms
    height
    170 mm
    width
    40 mm
    depth
    120 mm
    product weight
    0.38 kg
    mechanical robustness
    Earthquakes in operation ( level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3
    Earthquakes in operation ( level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3
    Jolts de-energized ( level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2
    Shocks de-energized ( level: 2) : 27 Gn/11 ms conforming to IEC 60255-21-2
    Shocks in operation ( level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2
    Vibrations de-energized ( level: 2) : 2 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1
    Vibrations in operation ( level: 2) : 1 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1
    Vibrations in operation ( level: Fc) : 2 Hz...13.2 Hz, a = +/- 1 mm conforming to IEC 60068-2-6
    auxiliary connection terminal
    Screw-type connectors 1 cable(s) 1.5 mm²
    Screw-type connectors 1 cable(s) 2.5 mm²
    Screw-type connectors 2 cable(s) 1 mm²
    Screw-type connectors 1 cable(s) 0.2...2.5 mm²
    Screw-type connectors 2 cable(s) 0.2...1 mm²
    Environment
    electromagnetic compatibility
    Fast transient bursts immunity tests-conducted disturbances : IV (4kV, 2.5 kHz ) conforming to IEC 61000-4-4
    Immunity to radiated fields immunity tests-radiated disturbances : III (10 V/m, 80 MHz...2 GHz ) conforming to IEC 61000-4-3
    Disturbing field emission emission tests : A conforming to EN 55022
    Fast transient bursts immunity tests-conducted disturbances : A and B (4kV, 2.5 kHz/2 kV, 5 kHz ) conforming to IEC 60255-22-4
    Immunity to conducted RF disturbances immunity tests-conducted disturbances : III (10 V ) conforming to IEC 60255-22-6
    Conducted disturbance emission emission tests : A conforming to EN 55022
    Immunity to magnetic fields at network frequency immunity tests-radiated disturbances : IV (30 A/m (continuous)-300 A/m (1-3 s) ) conforming to IEC 61000-4-8
    Surges immunity tests-conducted disturbances : III (2 kV CM, 1 kV DM ) conforming to IEC 61000-4-5
    1 MHz damped oscillating wave immunity tests-conducted disturbances (2.5 kV CM, 1 kV DM ) conforming to IEC 60255-22-1
    1 MHz damped oscillating wave immunity tests-conducted disturbances (2.5 kV CM, 2.5 kV DM ) conforming to ANSI C37.90.1
    100 kHz damped oscillating wave immunity tests-conducted disturbances (2.5 kV CM, 1 kV DM ) conforming to IEC 61000-4-12
    Conducted disturbance emission emission tests conforming to IEC 60255-25
    Disturbing field emission emission tests conforming to IEC 60255-25
    Electrostatic discharge immunity tests-radiated disturbances (8 kV air, 4 kV contact ) conforming to ANSI C37.90.3
    Electrostatic discharge immunity tests-radiated disturbances (8 kV air, 6 kV contact ) conforming to IEC 60255-22-2
    Fast transient bursts immunity tests-conducted disturbances (4kV, 2.5 kHz ) conforming to ANSI C37.90.1
    Immunity to radiated fields immunity tests-radiated disturbances (10 V/m, 80 MHz...1 GHz ) conforming to IEC 60255-22-3
    Immunity to radiated fields immunity tests-radiated disturbances (35 V/m, 25 MHz...1 GHz ) conforming to ANSI C37.90.2
    Voltage interruptions immunity tests-conducted disturbances (100 % during 100 ms ) conforming to IEC 60255-11
    climatic withstand
    Continuous exposure to damp heat (in operation) : Cab : 10 days, 93 % RH, 40 °C conforming to IEC 60068-2-78
    Continuous exposure to damp heat (in storage) : Cab : 56 days, 93 % RH, 40 °C conforming to IEC 60068-2-78
    Continuous exposure to damp heat (in storage) : Db : 6 days, 95 % RH, 55 °C conforming to IEC 60068-2-30
    Exposure to cold (in operation) : Ad : - 25 °C conforming to IEC 60068-2-1
    Exposure to cold (in storage) : Ab : - 25 °C conforming to IEC 60068-2-1
    Exposure to dry heat (in operation) : Bd : 70 °C conforming to IEC 60068-2-2
    Exposure to dry heat (in storage) : Bb : 70 °C conforming to IEC 60068-2-2
    Salt mist (in operation) : Kb/2 : 6 days conforming to IEC 60068-2-52
    Temperature variation with specified variation rate (in storage) : Nb : - 25 °C to 70 °C, 5 °C/min conforming to IEC 60068-2-14
    Influence of corrosion/gaz test 2 (in operation) : 21 days, 75 % RH, 25 °C, 0.5 ppm H2S, 1 ppm S02 conforming to IEC 60068-2-60
    Influence of corrosion/gaz test 4 (in operation) : 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.2 ppm NO2, 0.01 ppm CI2 conforming to IEC 60068-2-60
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Available
  • Documents and Downloads

    Language
    • English
    Catalogue
    Date
    Size
    Add to My Documents
    Date 2018/11/06
    Size 31 MB
    CAD
    Date
    Size
    Add to My Documents
    Connecting MES120 (n°1)
    Date 2012/02/23
    Size 5.4 KB
    Date 2012/02/23
    Size 55.6 KB
    Date 2012/02/23
    Size 96.7 KB
    Date 2012/02/23
    Size 23.2 KB
    Connecting MES120 (n°3)
    Date 2015/03/13
    Size 5.9 KB
    Date 2015/03/13
    Size 55.6 KB
    Date 2015/03/13
    Size 96.7 KB
    Date 2015/03/13
    Size 25.6 KB
    Connecting MES120 (n°2)
    Date 2012/02/23
    Size 5.8 KB
    Date 2012/02/23
    Size 55.6 KB
    Date 2012/02/23
    Size 96.7 KB
    Date 2012/02/23
    Size 25.3 KB
    Product environmental
    Date
    Size
    Add to My Documents
    Date 2017/09/21
    Size 96.7 KB
  • Technical FAQs

    No results found
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.