South Africa

Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

GV2L10 Product picture Schneider Electric

View all TeSys GV2

TeSys GV2 - GV2L10

Magnetic motor circuit breaker

GV2L10 Product picture Schneider Electric
View all TeSys GV2
TeSys GV2 - GV2L10
Magnetic motor circuit breaker

TeSys GV2 - Circuit breaker - magnetic - 6.3 A - screw clamp terminals

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range
    TeSys
    product name
    TeSys GV2
    device short name
    GV2L
    product or component type
    Circuit breaker
    device application
    Motor
    poles description
    3P
    network type
    AC
    utilisation category
    AC-3 conforming to IEC 60947-4-1
    Category A conforming to IEC 60947-2
    network frequency
    50/60 Hz conforming to IEC 60947-2
    breaking capacity
    100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
    100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
    100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
    100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
    4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
    [Ics] rated service short-circuit breaking capacity
    100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
    100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
    100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
    100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
    100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
    trip unit technology
    Magnetic
    magnetic tripping current
    78 A
    Complementary
    fixing mode
    Clipped on 35 mm symmetrical DIN rail
    Screwed on panel (with 2 x M4 screws)
    operating position
    Any position
    motor power kW
    3 kW at 500 V AC 50/60 Hz
    4 kW at 690 V AC 50/60 Hz
    2.2 kW at 400/415 V AC 50/60 Hz
    control type
    Rotary knob
    [Ue] rated operational voltage
    690 V AC 50/60 Hz conforming to IEC 60947-2
    [Ui] rated insulation voltage
    690 V AC 50/60 Hz conforming to IEC 60947-2
    [Uimp] rated impulse withstand voltage
    6 kV conforming to IEC 60947-2
    power dissipation per pole
    1.8 W
    mechanical durability
    100000 cycles
    electrical durability
    100000 cycles for AC-3 at 415 V
    operating rate
    40 cyc/h
    rated duty
    Continuous conforming to IEC 60947-4-1
    connections - terminals
    Screw clamp terminals 2 cable(s) 1...6 mm² solid
    Screw clamp terminals 2 cable(s) 1.5...6 mm² flexible without cable end
    Screw clamp terminals 2 cable(s) 1...4 mm² flexible with cable end
    tightening torque
    1.7 N.m on screw clamp terminals
    mechanical robustness
    Shocks 30 Gn conforming to IEC 60068-2-27
    Vibrations 5 Gn, 5...150 Hz conforming to IEC 60068-2-6
    suitability for isolation
    Yes conforming to IEC 60947-1
    phase failure sensitivity
    Yes
    height
    89 mm
    width
    45 mm
    depth
    97 mm
    product weight
    0.33 kg
    Environment
    standards
    EN 60204
    IEC 60947-1
    IEC 60947-2
    NF C 63-120
    NF C 63-650
    NF C 79-130
    VDE 0113
    VDE 0660
    product certifications
    BV
    CCC
    CSA
    DNV
    GL
    LROS (Lloyds register of shipping)
    RINA
    protective treatment
    TH
    IK degree of protection
    IK04
    ambient air temperature for operation
    -20...60 °C
    ambient air temperature for storage
    -40...80 °C
    fire resistance
    960 °C conforming to IEC 60695-2-1
    operating altitude
    0...2000 m
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Need no specific recycling operations
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    Catalogue
    Date
    Size
    Add to My Documents
    Date 2018/11/15
    Size 22.7 MB
    TeSys GV - Catalogue 2017 - Motor circuit breakers
    CAD
    Date
    Size
    Add to My Documents
    MAGNETIC CIRCUIT BREAKER
    Date 2018/10/30
    Size 522.7 KB
    Date 2018/10/30
    Size 269.9 KB
    Date 2018/10/30
    Size 735.5 KB
    Certificate
    Date
    Size
    Add to My Documents
    Date 2017/11/10
    Size 466.4 KB
    Date 2017/11/10
    Size 2.5 MB
    Instruction sheet
    Date
    Size
    Add to My Documents
    Date 2017/09/21
    Size 501.8 KB
    Date 2018/08/13
    Size 1.5 MB
    Date 2018/08/13
    Size 765.4 KB
    Declaration of conformity
    Date
    Size
    Add to My Documents
    Date 2018/07/14
    Size 520.9 KB
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    Date 2018/08/06
    Size 150.1 KB
  • Technical FAQs

    No results found
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Performance Curves

    Tripping Curves for GV2L or LE Combined with Thermal Overload Relay LRD or LR2K

    Average Operating Times at 20 °C Related to Multiples of the Setting Current


    1
    3 poles from cold state
    2
    2 poles from cold state
    3
    3 poles from hot state

    Current Limitation on Short-Circuit for GV2L and GV2LE Only (3-Phase 400/415 V)

    Dynamic Stress

    I peak = f (prospective Isc) at 1.05 Ue = 435 V


    1
    Maximum peak current
    2
    32 A
    3
    25 A
    4
    18 A
    5
    14 A
    6
    10 A
    7
    6.3 A
    8
    4 A
    9
    2.5 A
    10
    1.6 A
    11
    Limit of rated ultimate breaking capacity on short-circuit of GV2LE (14, 18, 23, and 25 A ratings).

    Current Limitation on Short-Circuit for GV2L and GV2LE + Thermal Overload Relay LRD or LR2K (3-Phase 400/415 V)

    Dynamic Stress

    I peak = f (prospective Isc) at 1.05 Ue = 435 V


    1
    Maximum peak current
    2
    32 A
    3
    25 A
    4
    18 A
    5
    14 A
    6
    10 A
    7
    6.3 A
    8
    4 A
    9
    2.5 A
    10
    1.6 A
    11
    Limit of rated ultimate breaking capacity on short-circuit of GV2LE (14, 18, 23, and 25 A ratings).

    Thermal Limit on Short-Circuit for GV2L Only

    Thermal Limit in kA2s in the Magnetic Operating Zone

    Sum of I2dt = f (prospective Isc) at 1.05 Ue = 435 V


    1
    25 A and 32 A
    2
    18 A
    3
    14 A
    4
    10 A
    5
    6.3 A
    6
    4 A
    7
    2.5 A
    8
    1.6 A

    Thermal Limit on Short-Circuit for GV2L and GV2LE + Thermal Overload Relay LRD or LR2K

    Thermal Limit in kA2s in the Magnetic Operating Zone

    Sum of I2dt = f (prospective Isc) at 1.05 Ue = 435 V


    1
    32 A (GV2LE32)
    2
    25 A and 32 A (GV2L32)
    3
    18 A
    4
    14 A
    5
    10 A
    6
    6.3 A
    7
    4 A
    8
    2.5 A
    9
    1.6 A
    10
    Limit of rated ultimate breaking capacity on short-circuit of GV2 LE (14, 18, 23, and 25 A ratings).


  • Dimensions Drawings

    GV2L

    Dimensions


    X1 Electrical clearance = 40 mm for Ue ≤ 415 V, or 80 mm for Ue = 440 V, or 120 mm for Ue = 500 and 690 V.

    X2 = 40 mm.

    GVAD, AM, AN, AU, AS


    1
    Maximum

    GV2AK00


    Mounting

    On rail AM1 DE200, AM1 ED200 (35 x 15)


    Panel mounted


    On pre-slotted mounting plate AM1 PA


    Adapter Plate GK2AF01


    7.5 mm Height Compensation Plate GV1F03


    Mounting

    Mounting of External Operator GV2APN01, GV2APN02 or GV2APN04 for Motor Circuit Breakers GV2L


    Door cut-out


    (1)
    For IP65 only.

    Mounting of External Operator GVAPH02 for Motor Circuit Breakers GV2L


    b

    Minimum

    Maximum

    GV2 APN●● + GV APH02

    151

    250

    GV2 APN●● + GV APH02 + GV APK11

    250

    445

    Door cut-out


    (1)
    For IP65 only.

    GV2L and GV2LE

    Sets of busbars GV2G445, GV2G454, GV2G472, with terminal block GV2G05


    l

    p

    GV2G445 (4 x 45 mm)

    179

    45

    GV2G454 (4 x 54 mm)

    206

    54

    GV2G472 (4 x 72 mm)

    260

    72

    Number of tap-offs

    a

    5

    6

    7

    8

    GV2G445

    224

    269

    314

    359

    GV2G454

    260

    314

    368

    422

    GV2G472

    332

    404

    476

    548

    Sets of Busbars for GV2L and GV2LE

    Sets of busbars GV2G●●● with terminal block GV1G09


    Sets of busbars GV2G245, GV2G254, GV2GR272


    I

    GV2G245 (2 x 45 mm)

    89

    GV2G254 (2 x 54 mm)

    98

    GV2G272 (2 x 72 mm)

    116

    Set of busbars GV2G554


    Sets of busbars GV2G345 and GV2G354


    I

    GV2G345 (3 x 45 mm)

    134

    GV2G354 (3 x 54 mm)

    152


  • Connections and Schema

    GV2L••