Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

LC2F185 Product picture Schneider Electric

View all TeSys F

TeSys F - LC2F185

Reversing contactors without coil

LC2F185 Product picture Schneider Electric
View all TeSys F

TeSys F - LC2F185

Reversing contactors without coil

TeSys F reversing contactor - 3P(3 NO) AC-3 <= 440 V 185 A - without coil

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range
    TeSys
    product name
    TeSys F
    product or component type
    Reversing contactor
    device short name
    LC2F
    contactor application
    Motor control
    Resistive load
    utilisation category
    AC-1
    AC-3
    device presentation
    Preassembled with reversing power busbar
    poles description
    3P
    pole contact composition
    3 NO
    [Ue] rated operational voltage
    <= 1000 V AC 50/60 Hz
    <= 460 V DC
    [Ie] rated operational current
    275 A (<= 40 °C) at <= 440 V AC AC-1
    185 A (<= 55 °C) at <= 440 V AC AC-3
    motor power kW
    55 kW at 220...240 V AC 50/60 Hz
    110 kW at 660…690 V AC 50/60 Hz
    100 kW at 1000 V AC 50/60 Hz
    100 kW at 415 V AC 50/60 Hz
    100 kW at 440 V AC 50/60 Hz
    110 kW at 500 V AC 50/60 Hz
    90 kW at 380...400 V AC 50/60 Hz
    auxiliary contact composition
    1 NO
    [Uimp] rated impulse withstand voltage
    8 kV
    overvoltage category
    III
    [Ith] conventional free air thermal current
    275 A at <= 40 °C
    Irms rated making capacity
    1850 A AC conforming to IEC 60947-4-1
    rated breaking capacity
    1480 A conforming to IEC 60947-4-1
    [Icw] rated short-time withstand current
    1500 A <= 40 °C 10 s
    920 A <= 40 °C 30 s
    740 A <= 40 °C 1 min
    500 A <= 40 °C 3 min
    400 A <= 40 °C 10 min
    associated fuse rating
    200 A aM at <= 440 V
    315 A gG at <= 440 V
    average impedance
    0.33 mOhm at 50 Hz - Ith 275 A
    [Ui] rated insulation voltage
    1000 V conforming to IEC 60947-4-1
    1500 V conforming to VDE 0110 group C
    power dissipation per pole
    12 W AC-3
    interlocking type
    Mechanical
    mounting support
    Plate
    standards
    EN 60947-1
    EN 60947-4-1
    IEC 60947-1
    IEC 60947-4-1
    JIS C8201-4-1
    product certifications
    ABS
    CCC
    CSA
    DNV
    LROS (Lloyds register of shipping)
    RINA
    RMRoS
    UL
    CB
    connections - terminals
    Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable end
    Power circuit : connector 1 cable(s) 150 mm²
    Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end
    Control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end
    Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - with cable end
    Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable end
    Control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable end
    Power circuit : lugs-ring terminals 1 cable(s) 150 mm²
    Power circuit : bar 2 x ( 25 x 3 mm)
    tightening torque
    Control circuit : 1.2 N.m
    Power circuit : 18 N.m
    Environment
    IP degree of protection
    IP2x front face with shrouds (ordered separately) conforming to IEC 60529
    IP2x front face with shrouds (ordered separately) conforming to VDE 0106
    protective treatment
    TH
    ambient air temperature for operation
    -5...55 °C
    ambient air temperature for storage
    -60...80 °C
    permissible ambient air temperature around the device
    -40...70 °C
    operating altitude
    3000 m without derating in temperature
    fire resistance
    850 °C conforming to IEC 60695-2-1
    mechanical robustness
    Vibrations contactor closed 5 Gn, 5...300 Hz
    Shocks contactor open 7 Gn for 11 ms
    Vibrations contactor open 2 Gn, 5...300 Hz
    Shocks contactor closed 15 Gn for 11 ms
    height
    174 mm
    width
    357 mm
    depth
    181 mm
    product weight
    10.1 kg
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    Certificate
    Date
    Size
    Add to My Documents
    Date 2017/11/10
    Size 2.1 MB
    Instruction sheet
    Date
    Size
    Add to My Documents
    Date 2015/07/27
    Size 2.6 MB
    Declaration of conformity
    Date
    Size
    Add to My Documents
    Date 2017/11/10
    Size 83.5 KB
    End of life manual
    Date
    Size
    Add to My Documents
    Date 2015/12/01
    Size 181.1 KB
    Date 2017/09/21
    Size 302.6 KB
    Product environmental
    Date
    Size
    Add to My Documents
    Date 2017/09/21
    Size 197.1 KB
    Technical leaflet
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions and Drawings
    Pre-assembled: LC2 F115 to F265 (Reverser supplied on 2 bars which can be used for fixing the device)



    NOTE: Bar fixing centers Vertical: 120 mm, Horizontal: a2 see table.

    NOTE: X1 (mm) = Minimum electrical clearance according to operating voltage and breaking capacity.

    LC1

    200…500 V

    660…1000 V

    F115, F150

    10

    15

    F185

    10

    15

    F225, F265

    10

    15

    LC2

    a

    a2

    b

    b1

    c

    G1

    J

    J1

    L

    M

    P

    P1

    Q1

    S

    f

    Ø

    F115

    3P

    345

    317

    162

    137

    171

    80

    71

    57

    107

    147

    37

    77

    60

    20

    131

    M6

    4P

    419

    378

    162

    137

    171

    80

    108

    75.5

    107

    147

    37

    77

    60

    20

    131

    M6

    F150

    3P

    345

    317

    170

    137

    171

    80

    71

    57

    107

    150

    40

    71

    57

    20

    131

    M8

    4P

    422

    381

    170

    137

    171

    80

    111

    75.5

    107

    150

    40

    71

    55.5

    20

    131

    M8

    F185

    3P

    357

    326

    174

    137

    181

    80

    78

    59.5

    113.5

    154

    40

    78

    59.5

    20

    130

    M8

    4P

    437

    390

    174

    137

    181

    80

    118

    79.5

    113.5

    154

    40

    78

    59.5

    20

    130

    M8

    F225

    3P

    357

    326

    197

    137

    181

    80

    78

    59.5

    113.5

    172

    48

    62

    51.5

    25

    130

    M10

    4P

    437

    390

    197

    137

    181

    80

    118

    79.5

    113.5

    172

    48

    54

    47.5

    25

    130

    M10

    F265

    3P

    425

    386

    203

    145

    213

    96

    109

    61.5

    141

    178

    48

    100

    66.5

    25

    147

    M10

    4P

    521

    464

    203

    145

    213

    96

    157

    85.5

    141

    178

    48

    100

    66.5

    25

    147

    M10

    NOTE: For customer assembly, fixing recommended on AM1 EC uprights, please consult your Regional Sales Office.

    2 x LC1 F115 to F330


    2 x LC1 F400, F500, F630, F800


    (1)
    Except LC1 F630 and F800: 4 x Ø10.5.
    (2)
    Except LC1 F630 and F800.

    NOTE: X1 (mm) = Minimum electrical clearance according to operating voltage and breaking capacity.

    LC1

    200…500 V

    660…1000 V

    200…690 V

    1000 V

    F115, F150

    10

    15

    F185

    10

    15

    F225, F265

    10

    15

    F330

    10

    15

    F400

    15

    20

    F500

    15

    20

    F630

    20

    30

    F800

    10

    20

    2 x LC1

    a

    b

    b1

    c

    G

    G1

    J

    J1

    J2

    J3

    L

    P1

    F115

    3P

    345

    162

    137

    171

    80

    71

    57

    107

    77

    4P

    419

    162

    137

    171

    80

    108

    75.5

    107

    77

    F150

    3P

    345

    170

    137

    171

    80

    71

    57

    107

    71

    4P

    422

    170

    137

    171

    80

    111

    75.5

    107

    71

    F185

    3P

    357

    174

    137

    181

    80

    78

    59.5

    113.5

    78

    4P

    437

    174

    137

    181

    80

    118

    79.5

    113.5

    78

    F225

    3P

    357

    197

    137

    181

    80

    78

    59.5

    113.5

    62

    4P

    437

    197

    137

    181

    80

    118

    79.5

    113.5

    54

    F265

    3P

    425

    203

    145

    213

    96

    109

    61.5

    141

    100

    4P

    521

    203

    145

    213

    96

    157

    85.5

    141

    100

    F330

    3P

    447

    206

    145

    219

    96

    124

    65.5

    145

    107

    4P

    543

    206

    145

    219

    96

    172

    89.5

    145

    107

    F400

    3P

    446

    206

    209

    219

    80

    170

    157

    64.5

    67

    19.5

    145

    107

    4P

    542

    206

    209

    219

    80

    170

    157

    112.5

    67

    67.5

    145

    107

    F500

    3P

    485

    238

    209

    232

    80

    170

    156

    84.5

    66

    39.5

    146

    112

    4P

    595

    238

    209

    232

    140

    230

    156

    79.5

    66

    34.5

    146

    112

    F630

    3P

    636

    304

    280

    255

    180

    139

    68.5

    155

    137

    4P

    796

    304

    280

    255

    240

    139

    88.5

    155

    137

    F800

    3P

    636

    304

    280

    255

    180

    139

    68.5

    155

    137


  • Connections and Schema

    Connections and Schema
    Reversing contactors for motor control LC2 F: 2xLC1 F Horizontally mounted


    Reversing contactors for motor control LC2 F: 2xLC1 F Vertically mounted


    Changeover contactor pairs for distribution LC2 F: 2xLC1 F Horizontally mounted


    Changeover contactor pairs for distribution LC2 F: 2xLC1 F Vertically mounted


    Electrical interlocking of reversers fitted with mechanical interlock without integral electrical contacts: LA9 F