Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

RE17LAMW Product picture Schneider Electric

Range: Zelio Time

Solid state Output

RE17LAMW

RE17LAMW Product picture Schneider Electric
Range: Zelio Time

Solid state Output

RE17LAMW

on-delay timing relay - 1 s..100 h - 24..240 V AC/DC - solid state output

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Zelio Time
    product or component type
    Modular timing relay
    discrete output type
    Solid state
    width
    17.5 mm
    component name
    RE17L
    time delay type
    A
    time delay range
    0.1...1 s
    1...10 h
    1...10 min
    1...10 s
    10...100 h
    6...60 min
    6...60 s
    nominal output current
    0.7 A
    Complementary
    control type
    Selector switch on front panel
    [Us] rated supply voltage
    24...240 V AC/DC at 50/60 Hz
    voltage range
    0.85...1.1 Us
    supply frequency
    50...60 Hz (+/- 5 %)
    control signal pulse width
    0.05 s typical
    insulation resistance
    100 MOhm at 500 V DC conforming to IEC 60664-1
    [Uimp] rated impulse withstand voltage
    5 kV (1.2/50 µs)
    power on delay
    < 100 ms
    connections - terminals
    Screw terminals, clamping capacity: 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12 (solid) without cable end
    Screw terminals, clamping capacity: 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14 (solid) without cable end
    Screw terminals, clamping capacity: 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14 (flexible) with cable end
    Screw terminals, clamping capacity: 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16 (flexible) with cable end
    tightening torque
    0.6...1 N.m conforming to IEC 60947-1
    dielectric strength
    2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1
    housing material
    Self-extinguishing
    repeat accuracy
    +/- 0.5 % conforming to IEC 61812-1
    temperature drift
    +/- 0.05 %/°C
    voltage drift
    +/- 0.2 %/V
    setting accuracy of time delay
    +/- 10 % of full scale at 25 °C conforming to IEC 61812-1
    reset time
    350 ms on de-energisation typical
    on-load factor
    100 %
    power consumption in VA
    0...3 VA at 240 V AC
    power consumption in W
    <= 1.5 W at 240 V DC
    breaking capacity
    0.5 A AC/DC conforming to UL
    0.7 A AC/DC at 20 °C
    operating frequency
    10 Hz
    maximum output current
    20 A <= 10 ms
    minimum switching current
    10 mA
    leakage current
    < 5 mA
    maximum switching voltage
    250 V AC/DC
    voltage drop
    4 V 3-wire
    8 V 2-wire
    electrical durability
    100000000 cycles
    marking
    CE
    creepage distance
    4 kV/3 conforming to IEC 60664-1
    safety reliability data
    MTTFd = 353.8 years
    B10d = 320000
    mounting position
    Any position in relation to normal vertical mounting plane
    mounting support
    35 mm DIN rail conforming to EN/IEC 60715
    product weight
    0.068 kg
    Environment
    immunity to microbreaks
    <= 20 ms
    derating factor
    5 mA/°C
    standards
    2004/108/EC
    EN 61000-6-1
    EN 61000-6-2
    EN 61000-6-3
    EN 61000-6-4
    IEC 61812-1
    2006/95/EC
    product certifications
    CSA
    cULus
    GL
    ambient air temperature for storage
    -30...60 °C
    ambient air temperature for operation
    -20...60 °C
    IP degree of protection
    IP20 (terminal block) conforming to IEC 60529
    IP40 (housing) conforming to IEC 60529
    IP50 (front panel) conforming to IEC 60529
    vibration resistance
    20 m/s² (f = 10...150 Hz) conforming to IEC 60068-2-6
    shock resistance
    15 gn (duration = 11 ms) conforming to IEC 60068-2-27
    relative humidity
    93 % without condensation conforming to IEC 60068-2-30
    electromagnetic compatibility
    Electrostatic discharge immunity test, in contact at 6 kV conforming to IEC 61000-4-2 level 3
    Electrostatic discharge immunity test, in air at 8 kV conforming to IEC 61000-4-2 level 3
    Susceptibility to electromagnetic fields, 80 MHz to 1 GHz at 10 V/m conforming to IEC 61000-4-3 level 3
    Electrical fast transient/burst immunity test, capacitive connecting clip at 1 kV conforming to IEC 61000-4-4 level 3
    Electrical fast transient/burst immunity test, direct at 2 kV conforming to IEC 61000-4-4 level 3
    1.2/50 µs shock waves immunity test, differential mode at 1 kV conforming to IEC 61000-4-5 level 3
    1.2/50 µs shock waves immunity test, common mode at 2 kV conforming to IEC 61000-4-5 level 3
    Conducted RF disturbances, 0.15...80 MHz at 10 V conforming to IEC 61000-4-6 level 3
    Voltage dips and interruptions immunity test, 1 cycle at 0 % conforming to IEC 61000-4-11
    Voltage dips and interruptions immunity test, 25/30 cycles at 70 % conforming to IEC 61000-4-11
    Conducted and radiated emissions conforming to EN 55022 class B
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Available
  • Documents and Downloads

    Language
    • English
    Catalogue
    Date
    Size
    Add to My Documents
    Date 2018/04/30
    Size 7.7 MB
    Certificate
    Date
    Size
    Add to My Documents
    UL Listed RE17, RE22, REXL, RE48A, RE88857, RE88865, RE88867, RENF22R2MMW
    Instruction sheet
    Date
    Size
    Add to My Documents
    Declaration of conformity
    Date
    Size
    Add to My Documents
    Date 2018/08/06
    Size 242.8 KB
    End of life manual
    Date
    Size
    Add to My Documents
    Date 2017/12/13
    Size 1.4 MB
  • Technical FAQs

    No results found
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Width 17.5 mm



  • Connections and Schema

    Internal Wiring Diagram



    Wiring Diagram



  • Technical Description

    Function A : Power on Delay Relay
    Description

    The timing period T begins on energisation. After timing, the output(s) R close(s). The second output can be either timed or instantaneous.

    Function: 1 Output


    Function: 2 Outputs


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)


    Legend

    Relay de-energised

    Relay energised

    Output open

    Output closed

    C

    Control contact

    G

    Gate

    R

    Relay or solid state output

    R1/R2

    2 timed outputs

    R2 inst.

    The second output is instantaneous if the right position is selected

    T

    Timing period

    Ta -

    Adjustable On-delay

    Tr -

    Adjustable Off-delay

    U

    Supply