Bienvenue sur le site Web de Schneider Electric

Bienvenue sur notre site Web.

Choisissez un pays ou une région

Welcome the the Schneider Electric French website. It looks like you are located in the United States, would you like to change your location?

Traduisez en francais

EM3500 series

Compact, affordable series of DIN mounted meters

DIN rail energy meters for monitoring in building automation systems

EM3500 series
  • Fonctionnalité

    The PowerLogic EM3500 series energy meters combine exceptional performance and easy installation to deliver cost-effective power monitoring applications to your customers. The DIN rail-mounted meters can be surface mounted as needed.

    The PowerLogic EM3500 series meters come in four models.

    EM3502

    • Pulse outputs for real and reactive energy consumption
    • Real-time alarm output
    • All other measurements available on backlit LCD display

    EM3550

    • 2-wire RS-485 serial communication with Modbus RTU protocol
    • Pulse outputs for real energy consumption and real-time alarms
    • 2 quadrant metering

    EM3555

    • 2-wire RS-485 serial communication with Modbus RTU protocol
    • Pulse outputs for real energy consumption and real-time alarms
    • 4 quadrant metering
    • Logging capacity

    EM3560

    • 2-wire RS-485 serial comm with BACnet MS/TP protocol
    • Pulse inputs to accommodate sensors measuring other forms of energy
    • 2 quadrant metering
    • Logging capacity

    Common characteristics

    • ANSI C12.20 class 0.5% and IEC 62053-22 Class 0.5S for active energy
    • Class 2% for reactive energy
    • Supports single phase, split-phase, or 3-phase circuit configuration (delta or wye)
    • Backlit LCD display
    • All Models provide a full range of data measurements
    • Uses low-voltage CTs (1V or 1/3V)
    • External control power supply (90-600 V) for maximum flexibility
    • Operating Temperature -30°C to 70°C


    Bénéfices

    Low voltage current transformer (LVCT) connections are more compact and provide lower installation costs and a safer environment.

    Native building automation protocols (BACnet or LONworks) allows for direct integration into building management system (BMS) software.

    600 V direct connections for measurement inputs and control power reduce the need for potential transformers, which saves space and installation costs.

    Applications

    Energy efficiency and cost control applications (cost management)

    • Bill verification
    • Tenant metering (commercial sub metering)
    • Cost allocation
    • Green technologies monitoring (Renewables)

    Power availability and reliability applications (network management)

    • Power metering
    • Basic network monitoring

EcoStruxure™

EcoStruxure vous permet de vous épanouir dans le monde numérique d'aujourd'hui. Prenez de meilleures décisions en affaire grâce à des solutions IT / OT évolutives et convergentes.

Nous contacter

Vous avez une question, un doute, une demande ou vous souhaitez nous envoyer vos commentaires pour améliorer votre expérience avec Schneider Electric?

Questions fréquentes (FAQ)

Trouvez et partagez facilement la réponse que vous recherchez à partir de notre service FAQ en ligne.