MiCOM P64x

"MiCOM P642, P643 and P645 preserves service life, and offering fast protection for transformer faults."

Part of PowerLogic™

"Easergy MiCOM P64x series provides fast and complete protection for transformer faults, preserving service life. Designed for two and three winding transformers (including autotransformers), it is easy to use and the setting wizard requires only nameplate data. Models available: MiCOM P642, MiCOM P643, MiCOM P645"
MiCOM P64x Schneider Electric "MiCOM P642, P643 and P645  preserves service life, and offering fast protection for transformer faults."

Features

Transformers are high capital cost assets in electrical power systems. Elimination of all electrical and mechanical stresses, although desirable to preserve transformer life, is impractical. Adaptive techniques to measure and alarm (or trip) in such instances, and advise on cumulative service duty, can help to schedule preventive maintenance – before a costly failure occurs.

Internal faults are a risk for all transformers, with short-circuits dissipating the highest localized energy. Unless cleared quickly, the possibility to rewind windings reduces, and core damage may become irreparable. MiCOM P642, P643 and P645 Advanced Transformer Protection and Control

The MiCOM P642, P643 and P645 address all these issues - preserving service life, and offering fast protection for transformer faults. Hosted on an advanced IED platform, the P64x incorporates differential, REF, thermal, and overfluxing protection, plus backup protection for uncleared external faults. Model variants cover two and three winding transformers (including autotransformers), with up to 5 sets of three-phase CT inputs.

Large CT counts are common in ring bus/mesh corner applications, where the P64x summates currents to create each total winding current, easing application of backup protection. Backup overcurrent can be directionalized, where the user includes the optional 3-phase VT input in their chosen model.

Contractual warranty

Period : 2 years

Benefits

  • Universal IED for all transformer (or reactor) configurations
  • Protection, control, monitoring, measurements and recording in-one device
  • Backup and logging of through faults
  • Simple to specify, set, and commission
  • Programmable function keys

Additional Links

  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Centre
  • Find our Offices
  • Where to buy
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • General Terms of Business
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings