브랜드

슈나이더 일렉트릭 코리아 웹사이트에 방문해 주셔서 감사합니다.

슈나이더 일렉트릭 코리아 웹사이트 방문자 분들 모두 환영합니다.
		
오늘 무엇을 도와드릴까요?
What is the difference between isolated and non-isolated coaxial sockets? e.g. GUE7011W
A non-isolated coax socket is a standard socket.  If you wish to install a socket to connect your TV coax lead into, this is what is required.  Also, this version must be used for satellite installation as a two way signal is required.  The satellite box does not only receive a signal, it also sends a signal back to the satellite dish.  An isolated coax socket will block the return signal.

An isolated socket lets the signal through from the aerial/satellite dish but does not allow any kind of return signal/current.  This type of socket would be used where a communal dish or aerial is installed, such as in an apartment block.  The isolated socket blocks interference from receivers (televisions, digital boxes, satellite boxes) which spoils the signal which the rest of the users receive.

슈나이더 일렉트릭 Korea

자세히 알아보기
제품군
자세히 알아보기
제품군
  • 제품 문서
  • 소프트웨어 다운로드
  • 제품 선택기
  • 제품 대체 및 교체
  • 지원 및 연락처 센터
  • 영업소 검색
  • 견적 받기
  • 슈나이더 일렉트릭 커뮤니티
  • 채용
  • 회사 소개
  • 부정 행위 보고
  • 접근성
  • 뉴스룸
  • 투자자
  • Ecostruxure
  • 작업 검색
  • 블로그
  • 개인정보 취급방침
  • 쿠키 공지
  • 사용 약관
  • Change your cookie settings