Issue
This method can be utilized in testing database connectivity/authentication between servers.

Product Line
Power Monitoring Expert 7.2.2
Power Monitoring Expert 8.2
Power Monitoring Expert 9.0
Power Monitoring Expert 2020
Power Monitoring Expert 2021
Power Monitoring Expert 2022
Power Monitoring Expert 2023
Power Monitoring Expert 2024

Environment

Windows OS

Windows SQL Server

Resolution
There is a built-in Windows utility that can be used for testing SQL Database connections. This tool can be useful when testing username\passwords, as well as connections to remote database servers.



1) On the Desktop, right click and create a New Text Document. (Note: "Hide extensions for known file types" must NOT be checked in the Folder Options")
2) Change the file extension from .txt to .udl.
3) Double Click on the .udl file to bring up the Data Link Properties window.

Data Link Properties

4) Enter the name of the SQL Server you are trying to connect to. <Servername>\<Instance>

name of the SQL Server

5) Enter the user credentials being tested.

user credentials

6) Select the database from the drop down list. (If there is no connection to the database server, this step will fail).

 Select the database

7) Click "Test Connection". If successful, you will get a message saying "Test connection succeeded".
Test Connection

슈나이더 일렉트릭 Korea

자세히 알아보기
제품군
자세히 알아보기
제품군
  • 제품 문서
  • 소프트웨어 다운로드
  • 제품 선택기
  • 제품 대체 및 교체
  • 지원 및 연락처 센터
  • 영업소 검색
  • 견적 받기
  • 슈나이더 일렉트릭 커뮤니티
  • 채용
  • 회사 소개
  • 부정 행위 보고
  • 접근성
  • 뉴스룸
  • 투자자
  • Ecostruxure
  • 작업 검색
  • 블로그
  • 개인정보 취급방침
  • 쿠키 공지
  • 사용 약관
  • Change your cookie settings