브랜드

Impact-Company-Logo-English Black-01-177x54

슈나이더 일렉트릭 코리아 웹사이트에 방문해 주셔서 감사합니다.

슈나이더 일렉트릭 코리아 웹사이트 방문자 분들 모두 환영합니다.
		
오늘 무엇을 도와드릴까요?
When you have a power failure or when you switch off the power, the outgoing of XB5S will be have the last Status, that means, that the outgoing is in...

Goals and Symptoms

When you have a power failure or when you switch off the power, the outgoing of XB5S will be have the last Status, that means, that the outgoing is in "Switch on" Position. Is this true? It is dangerous when you have switched a function and you can't set it back after power failure. Is this known for you?

Causes and Fixes

They have a PNP or NPN transistor output. This means that when the product is not powered anymore, the transistor output will not be triggered, and the output will become or stay open, depending of its initial state.

The Biometric switch memorise the state of the output before power off. This means that when it will be powered again the output will come back to the state it was before power off.


Legacy KB System (APS) Data: RESL201136 V1.0, Originally authored by LaBe on 01/27/2010, Last Edited by LaBe on 01/27/2010
Related ranges: Harmony XB5S

슈나이더 일렉트릭 Korea

  • 제품 문서
  • 소프트웨어 다운로드
  • 제품 선택기
  • 제품 대체 및 교체
  • 지원 및 연락처 센터
  • 영업소 검색
  • 견적 받기
  • 슈나이더 일렉트릭 커뮤니티
  • 채용
  • 회사 소개
  • 부정 행위 보고
  • 접근성
  • 뉴스룸
  • 투자자
  • Ecostruxure
  • 작업 검색
  • 블로그
  • 개인정보 취급방침
  • 쿠키 공지
  • 사용 약관
  • Change your cookie settings