How To Log Visits to an ION Enterprise WebReach Site

Issue

Show a detailed log of WebReach site visitors for an ION Enterprise WebReach deployment.

Product Line

ION Enterprise (WebReach)
PME
Note: WebReach was replaced by Web Applications for PME 9.0 and newer.

Environment

Internet Information Services (IIS)

Cause

Auditing or troubleshooting requires a visitor/access log (IP, user agent, timestamps, status codes) for the WebReach site. IIS logging provides this information.

Resolution

Perform all actions with appropriate server change controls. No references inside this section (per your guideline).

Enable logging on the WebReach virtual directory (IIS)
a. Open Control Panel → Administrative Tools → Internet Information Services (IIS) Manager.
b. In the Connections tree, expand ServerName → Web Sites → Default Web Site → ION (the WebReach virtual root). Right‑click ION → Properties.
c. On the Virtual Directory tab, check Log visits.

ION properties

2. Locate the site log settings and file path
a. In IIS, right‑click the parent of the ION virtual directory (typically Default Web Site) → Properties.
b. On the Web Site tab, ensure Enable logging is selected, then click Properties to view the log file directory and format.

Web site properties

*This will show the location of the log file. You can change the location by clicking the Browse button.

Logging properties

3. Read the log file: Navigate to the path shown in Step 2 (e.g., the site’s W3C log directory), then open the relevant W3C log file to review visitor entries (date, time, client IP, method, URI, status, user agent, etc.).

Notepad

Recommendation:

If you are using an older version of PME, consider upgrading to the latest version for improved protocol support and security. For assistance with integration or upgrades, contact Schneider Electric Technical Support at: pmo.support@se.com

Support information

슈나이더 일렉트릭 Korea

자세히 알아보기
제품군
자세히 알아보기
제품군
  • 제품 문서
  • 소프트웨어 다운로드
  • 제품 선택기
  • 제품 대체 및 교체
  • 지원 및 연락처 센터
  • 영업소 검색
  • 견적 받기
  • 슈나이더 일렉트릭 커뮤니티
  • 채용
  • 회사 소개
  • 부정 행위 보고
  • 접근성
  • 뉴스룸
  • 투자자
  • Ecostruxure
  • 작업 검색
  • 블로그
  • 개인정보 취급방침
  • 쿠키 공지
  • 사용 약관
  • Change your cookie settings