브랜드

슈나이더 일렉트릭 코리아 웹사이트에 방문해 주셔서 감사합니다.

슈나이더 일렉트릭 코리아 웹사이트 방문자 분들 모두 환영합니다.
		
오늘 무엇을 도와드릴까요?
Cannot delete type 2 user from the Unity Security Editor
Issue
Cannot delete 'Type 2' user from the Unity Security Editor

Product Line
EcoStruxure Control Expert (formerly known as Unity Pro)

Environment
Unity Pro v8.1

Resolution
Exporting the list of users for the Concept security editor creates a text file that shows the user as a 'Type 2'.  If you import the file into the Unity Security Editor, the 'Type 2' user will be added as a predefined user.  If you try to delete the user from the Unity Security Editor, it returns the error message  'user_xxxxx is a predefined user.  Predefined users cannot be deleted or modified.  Delete cancelled.'.  If you try to uninstall the editor by deleting Unity and reinstalling it, the user will still be shown in the list for the Security Editor.

The pre-defined users for Security Ediotr does not get deleted when Unity is uninstalled using the Control Panel.  The only way to delete the user is to uninstall Unity by using the 'UPCleaner.exe' tool for Unity and deleting any Unity installed folder.  Each version of Unity has it's own version of the UPCleaner tool.  To obtain the correct version of the UPCleaner tool, contact your local Schneider Electric help desk.

슈나이더 일렉트릭 Korea

자세히 알아보기
제품군
자세히 알아보기
제품군
  • 제품 문서
  • 소프트웨어 다운로드
  • 제품 선택기
  • 제품 대체 및 교체
  • 지원 및 연락처 센터
  • 영업소 검색
  • 견적 받기
  • 슈나이더 일렉트릭 커뮤니티
  • 채용
  • 회사 소개
  • 부정 행위 보고
  • 접근성
  • 뉴스룸
  • 투자자
  • Ecostruxure
  • 작업 검색
  • 블로그
  • 개인정보 취급방침
  • 쿠키 공지
  • 사용 약관
  • Change your cookie settings